![IPM 830802 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/ipm/830802/830802_operation-manual_2089095020.webp)
20
Pump viscosity guide
All calculations in Centipoise (cps)
Air pressure requirements:
For optimum pump performance, 40 – 100 PSI
should be supplied to the IP05 series transfer pumps.
IP01 series pumps: 1 – 2,000 cps
IP02 series pumps: 1 – 4,000 cps
OP series pumps: 1 – 4,000 cps
IP05 series pumps: 1 – 10,000 cps
IP10 series pumps: 1 – 20,000 cps
IP15 series pumps: 1 – 20,000 cps
IP30 series pumps: 1 – 20,000 cps
Calculations are based on the following general guidelines
z
Inbound air pressure: 100 psi
z
Pressure at dispense point: 0 psi
z
Hose/pipe length w/smooth inner surface = L: 25 feetxHose size = D: ¾”
z
Flow rate = Q: 2 gpm
z
Viscosity
=
V:
z
Pressure loss in hose/pipe (psi), P: P = 0.0273QVL/D4
The above viscosity values are only general guidelines. Other factors should always be taken into consideration
such as; dispensing valves, fittings, hose unions, elevation, outside ambient temperature, etc.