Safety instructions 

-

Read the instruction manual carefully before operating!

-

Mounting, installation and setting may only be carried out by qualified personnel!

-

Never use these products in applications where the safety of a person depends on their functionality!

Notes 

-

Insert only anti-twist pistons on the cylinder!

-

Use exclusively the enclosed hexagon socket key or a plastic pen!

-

Check periodically the fittings and plug-in connections!

Start up 

1. 

2. 

1. Insert  the  sensor  from  above  at  centre  into  the  C-

groove  and  fix  it  with  the  enclosed  hexagon  socket  key. 

Pay attention on the centre of the sensor  . The maximum 

tightening torque is 0,1Nm.

Then  connect  the  operating  voltage  (please  note  the 

technical data and the connection diagram).

2. Teach-in of the switching points

-

Determine the piston position for switching point 1.

-

Press the teach-button for 3 seconds, LED 1 flashes.

-

Release  the  teach-button,  switching  point  1  is 

stored.

-

LED 2 flashes.

-

Determine the piston position for switching point 2 .

-

Press briefly the teach-button, switching point 2 is 

stored.

3.  Control of the switching points

Move  the  piston  into  the  position  for  switching  point  1. 

LED  1  has  to  light  up.  If  it  doesn’t  light  up,  check  the 

operating  conditions  and  teach  the  switching  point 

again.
Move the piston into the position for switching point 2. 

LED 1 has to switch off and LED 2 has to light up.
If  LED  1  doesn’t  switch  off  or  LED  2  dosn’t  light  up, 

check  the  operating  conditions  and  teach  the  device 

again.

MANUAL

 • Subject to alteration! Version: July 2015 

ipf electronic gmbh

 • Rosmarter Allee 14 • 58762 Altena 

 Tel +49 2351 9365-0 • Fax +49 2351 9365-19 

 [email protected] • 

www.ipf-electronic.com 

2

 

Отзывы: