1.  Teach-in of the measuring range

 

 

 

 

 

 

 

 

2.   Changing the output function  
      (4 ... 20mA - 0 ... 10V) 
 

 

 

 

 

 

 

 

 

 

3.   LED display after each teach 

process 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Master-/slave funktion 

With the help of this function, up to 10 sensors of the same type can be operated in parallel. 
To do this, configure the devices accordingly via IO-Link. Define one sensor as the master and all 

others as slaves. The master must be assigned the highest number in the network. 
Then connect the black wires (PIN 4) with each other (see connection diagram). 
The following operating modes can be selected: 
1.   Synchronous operation:   The transmission pulse of all sensors occurs simultaneously with 

synchronized evaluation. Select this function for monitoring large 

areas. 

 2.  Multiplex operation: 

The transmission pulses of the sensors are time-delayed in a defined 

sequence. The devices can thus no longer influence each other, 

smaller distances between them are possible. 

 

 

 

Note: 

Resetting to the factory setting is only possible via IO-Link.

 

 

 

SAFETY INSTRUCTIONS:  

Before commissioning, please make sure that all safety instructions listed in the product documentation, if applicable, 

have been observed! 
In case of direct impact on personal safety, the use of these products is prohibited. 

 

Содержание UT189023

Страница 1: ...ble via IO Link Push Pull no nc switchable Output current max load 150mA Short circuit proof Reverse polarity protected Voltage drop 2 0V DC Switching frequency 5Hz Current consumption without load 40mA Standard measuring plate 200 x 200mm Resolution 1 0mm Repeatability 1mm Linearity error 0 5 Mounting distance sensor to sensor 700mm Setting Teach In Carrier frequency 400kHz Protection class III I...

Страница 2: ...It is imperative that the transducer surface as well as the area of the detection lobe are kept free Make sure that there are no interfering objects between the sensor and the target object inside the lobe Otherwise it is possible that the interfering object will cause false switching Also avoid positioning two or more ultrasonic sensors opposite each other Temperature The speed of sound in air de...

Страница 3: ...r than 6 seconds 2 The physical quantity of the analog output is changed instead of current output 4 20mA voltage output 0 10V or vice versa Note Be aware that a considerably larger load resistance is required for operation as a voltage output see technical data It is therefore recommended to disconnect the analog output before each change of the output function to avoid device damage 3 LED displa...

Страница 4: ... Then connect the black wires PIN 4 with each other see connection diagram The following operating modes can be selected 1 Synchronous operation The transmission pulse of all sensors occurs simultaneously with synchronized evaluation Select this function for monitoring large areas 2 Multiplex operation The transmission pulses of the sensors are time delayed in a defined sequence The devices can th...

Отзывы: