1

 

 

UT189023 

Ultrasonic sensors 

Diffuse reflection sensor 

 

 

I

 

Measuring 

range adjustable via teach-in

 

I

 

Analog output

 

I

 

M12-connector

 

 

 

 

TECHNICAL DATA

 

 

Scanning range 

150 … 1500mm 

Operating voltage U

B

 

18 … 30V DC 

Analog output 

0 … 10V, 4 … 20mA switchable, not reverse polarity 

protected 

Load resistance (4 … 20mA) 

< 400

 

Load resistance (0 … 10V) 

> 10k

 

Switching output (adjustable via IO-Link) 

Push-Pull, no/nc switchable 

Output current (max. load) 

150mA 

Short-circuit proof 

Reverse polarity protected 

Voltage drop 

2.0V DC 

Switching frequency 

5Hz 

Current consumption (without load 

40mA 

Standard measuring plate 

200 x 200mm 

Resolution 

1.0mm 

Repeatability 

1mm 

Linearity error 

0.5% 

Mounting distance (sensor to sensor) 

700mm 

Setting 

Teach-In 

Carrier frequency 

400kHz 

Protection class 

III 

Insulation dielectric strength 

500V 

Protection class (EN 60529) 

IP 67 

Material (housing) 

Brass nickel plated 

Temperature (operation) 

-25 … +70°C 

Temperature drift 

0.2%/K (uncompensated) 

Connection 

M12-connector 4-pole 

Connection accessories 

e.g

VK200325

 

 

Connection

 

 

 

 

 

IO-Link interface 

4 … 20mA / 0 … 10V switchable 

 

 

 

 

 

 

Dimensional 

drawing 

 

Sound outlet 

Содержание UT189023

Страница 1: ...ble via IO Link Push Pull no nc switchable Output current max load 150mA Short circuit proof Reverse polarity protected Voltage drop 2 0V DC Switching frequency 5Hz Current consumption without load 40mA Standard measuring plate 200 x 200mm Resolution 1 0mm Repeatability 1mm Linearity error 0 5 Mounting distance sensor to sensor 700mm Setting Teach In Carrier frequency 400kHz Protection class III I...

Страница 2: ...It is imperative that the transducer surface as well as the area of the detection lobe are kept free Make sure that there are no interfering objects between the sensor and the target object inside the lobe Otherwise it is possible that the interfering object will cause false switching Also avoid positioning two or more ultrasonic sensors opposite each other Temperature The speed of sound in air de...

Страница 3: ...r than 6 seconds 2 The physical quantity of the analog output is changed instead of current output 4 20mA voltage output 0 10V or vice versa Note Be aware that a considerably larger load resistance is required for operation as a voltage output see technical data It is therefore recommended to disconnect the analog output before each change of the output function to avoid device damage 3 LED displa...

Страница 4: ... Then connect the black wires PIN 4 with each other see connection diagram The following operating modes can be selected 1 Synchronous operation The transmission pulse of all sensors occurs simultaneously with synchronized evaluation Select this function for monitoring large areas 2 Multiplex operation The transmission pulses of the sensors are time delayed in a defined sequence The devices can th...

Отзывы: