Teach-in procedure for 1 point teach (normal): 

1.

 

Adjust the sensor to the object to be detected and make sure that the blue 
teach LED is on. 

2.

 

Touch the blue teach LED at the back of the housing with a ferromagnetic tool 
for 

longer than 2 seconds, but shorter than 4 seconds

, until all 3 LEDs flash at 

1Hz

.  

The blue LED lights up more strongly as soon as a tool is detected. 

3.

 

Touch the blue teach LED again quickly with a ferromagnetic tool to confirm the 
position of the object. 

4.

 

If

 

the sensor is to operate as a normally closed contact (output switched off when 

object is detected), touch the blue teach LED again quickly with a ferromagnetic 
tool within 4 seconds, otherwise

 

the device operates as a normally open contact. 

During this time, all 3 LEDs flash slowly (1Hz). 

5.

 

As soon as the blue LED lights up, the teaching process is completed. 

 

Teach-in procedure for 2-point teach (for objects close to the background):

 

 

1.

 

Adjust the sensor to the object to be detected and make sure that  
the blue teach LED is on. 

2.

 

Touch the blue teach LED at the back of the housing with a ferromagnetic tool for 

longer than 4 seconds, but shorter than 6 seconds

, until all 3 LEDs flash at 

2Hz

The blue LED is on more strongly as soon as a tool is detected. 

3.

 

Touch the blue teach LED again quickly with a ferromagnetic tool to confirm 
the position of the object. 

4.

 

Remove the object from the detection range and touch the blue teach LED 
quickly to teach the background. 

5.

 

As soon as the blue LED is on, the teaching process is completed. 

 

If all 3 LEDs are blinking fast (8Hz), the teach process has failed and must be repeated. 

 

 

 

 

Note:  

The yellow LED signals whether an object is detected and does not necessarily correspond to the state of the 

switching output.. The teach-in function locks 5min after switching on! The teach-in process works both with 

a ferromagnetic tool and via pin 2 of the M12 connector (white wire) by connecting it to the operating volt-

age (+Ub). 

 

Reset to factory setting

   

Touch the blue teach LED at the back of the housing with a ferromagnetic tool for approx.  

6 seconds until all 3 LEDs are blinking fast (4Hz) and pull the tool away immediately after the 

blinking frequency has set in. Afterwards, the blue teach LED should be on continuously again  

and the sensor returns to the delivery settings.

 

 