INTRODUCTION 

IPEX 

PH232Y12

 is a 1 to 2 RS-232 HUB that provides #2 RS-232 (Full Duplex) ports from one single 

RS-232 port. It works with Baud-Rate from 300bps to 230400bps. Using this device, you can connect 
a RS-232 line, to 2 different devices. 

PH232Y12

 can also be used as a RS-232 Repeater, Amplifier and Y-Switch. All communications are 

Full-Duplex. In addition, 3kV Optical and Electrical insulations have been used in the design of this 
device, this means all the ports are insulated from each other, so using this device in the RS-232 
line, can be very effective in eliminating electrically and electromagnetically noises. Also, the length 
of the RS-232 line increases from 15m to 30m (15m on each side). 
Protection against Surge, ESD and EMI is considered in its design, so, 

PH232Y12 

is good for industrial 

usage and are useful for Industrial Automation, Telecommunications, SCADA systems, DCS 
systems...  

2.

 

SPECIFICATIONS

 

 

RS-232 Repeater,

 HUB, Isolator and Amplifier; 

 

Number of Ports: 

#1 RS-232 to #2 RS-232 Bi-Directional HUB;

 

 

Serial Standard: 

Meets or Exceeds the Requirements of TIA/EIA-232-F and ITU v.28 Standards;

 

 

RS-232 Signal:

 TxD, RxD, GND; 

 

RS-232 Parity: 

Even, Odd, None, Mark and Space; 

 

Fully 

Plug & Play; 

 

Wide Range Power Supply: 

+8V to +48V DC; 

 

Serial Transmission Speed

 up to 230.4 kbps; 

 

Power (Green)

 LED Indicator; 

 

Transmit (Blue)

 and 

Receive (Yellow)

 LED Indicator; 

 

Isolation Protection:

 3kV Instantaneous, 500V DC Continuous; 

 

Surge Protection:

 Embedded 1500W Surge Protection; 

 

Magnetic Isolation:

 1.5 kV Built-in; 

 

ESD Protection: 

RS-232 Bus-Pin ESD Protection Exceeds ±15 kV Using Human-Body Model (HBM);

 

 

Dimensions:

 145mm x 118mm x 27mm (5.70in x 4.65in x 1.06in); 

 

Operating Temperature:

 -10°C to +70°C (+14°F to +158°F); 

 

1 Year Guarantee

 and 

5 Years Support.

 

Содержание PH232Y12

Страница 1: ...Doc No PH232Y12 UM 001 IPEX IP Electronix 16 January 2022 USER S MANUAL PH232Y12 1 to 2 RS 232 ISOLATED HUB REPEATER ISOLATOR and Y Switch...

Страница 2: ...www ipelectronix com IPEX IP Electronix PH232Y12 User s Manual Page 2 of 12 Doc No PH232Y12 UM 001 16 January 2022...

Страница 3: ...UM 001 16 January 2022 CONTENTS 1 INTRODUCTION 4 2 SPECIFICATIONS 4 3 PACKAGE CHECKLIST 5 4 TOP VIEW 6 5 BOTTOM VIEW 6 6 FRONT VIEW 6 7 BACK VIEW 6 8 RS 232 SERIAL PORTS PIN CONFIGURATION 7 9 PH232Y12...

Страница 4: ...e Protection against Surge ESD and EMI is considered in its design so PH232Y12 is good for industrial usage and are useful for Industrial Automation Telecommunications SCADA systems DCS systems 2 SPEC...

Страница 5: ...stalling the PH232Y12 verify that the package contains the following items 1 1 PH232Y12 2 1 RS 232 Male to Female Cable 3 1 Document and Driver CD ROM 4 2 DB9 Female Connector 5 1 220V AC to 12V DC Ad...

Страница 6: ...www ipelectronix com IPEX IP Electronix PH232Y12 User s Manual Page 6 of 12 Doc No PH232Y12 UM 001 16 January 2022 4 TOP VIEW 5 BOTTOM VIEW 6 FRONT VIEW 7 BACK VIEW...

Страница 7: ...TS PIN CONFIGURATION 1 2 3 4 5 6 7 8 9 PIN DCD RxD TxD DTR GND DSR RTS CTS RI NAME INPUT OUTPUT INPUT INPUT INPUT OUTPUT OUTPUT INPUT GROUND TYPE Data Terminal Equipment DTE 1 2 3 4 5 6 7 8 9 PIN DCD...

Страница 8: ...www ipelectronix com IPEX IP Electronix PH232Y12 User s Manual Page 8 of 12 Doc No PH232Y12 UM 001 16 January 2022 9 PH232Y12 CONNECTION DIAGRAM...

Страница 9: ...ces Modem or other DCE devices DB9 Female Pin Number DTE DB9 Male Pin Number Pin 1 DCD Output Pin 1 DCD Input Pin 2 RxD Output Pin 2 RxD Input Pin 3 TxD Input Pin 3 TxD Output Pin 4 DTR Input Pin 4 DT...

Страница 10: ...C or other DTE devices DB9 Male Pin Number DTE DB9 Male Pin Number Pin 7 RTS Output Pin 1 DCD Input Pin 3 TxD Output Pin 2 RxD Input Pin 2 RxD Input Pin 3 TxD Output Pin 6 DSR Input Pin 4 DTR Output P...

Страница 11: ...nuary 2022 Simple Null Modem Connection to PC PLC Without Hardware Flow control PC PLC or other DTE devices DB9 Male Pin Number DTE DB9 Male Pin Number Pin 3 TxD Output Pin 2 RxD Input Pin 2 RxD Input...

Страница 12: ...ARANTEE All products manufactured by IPEX are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser 12 TECHNICAL SUPPORT If you have...

Отзывы: