IPETRONIK M-THERMO 96 Скачать руководство пользователя страница 1

Hardware_Manual_M-THERMO_96

9. Juli 2019

Содержание M-THERMO 96

Страница 1: ...Hardware_Manual_M THERMO_96 9 Juli 2019...

Страница 2: ...Hardware setup 5 2 1 1 Ethernet Interface via IPEhub2 5 2 1 2 CAN interface 8 3 Device configuration via web interface 10 3 1 Page Configuration All channel overview 11 3 2 Chanel Configuration 12 3...

Страница 3: ...components of the electrical system electronics brake system engine and transmission control chassis body Tap of one or several bus systems CAN LIN ETHERNET including the required electrical connecti...

Страница 4: ...tial error messages 1 2 2 Support Headquarter IPETRONIK GmbH Co KG Im Rollfeld 28 76532 Baden Baden Germany Phone 49 7221 9922 0 Fax 49 7221 9922 100 info ipetronik com Website www ipetronik com Limit...

Страница 5: ...test bench applications 2 1 Hardware setup 2 1 1 Ethernet Interface via IPEhub2 To use the M THERMP 96 with an Ethernet interface to the PC the following hardware is required I Cable 620 233 xxx I Ca...

Страница 6: ...sts of 2 CAN interfaces represented as LEMO 9 pole M CAN connector and the second one in the SUB D 9 format The 2 CAN busses are connected to the IPEhub2 which is then sending the data over Ethernet t...

Страница 7: ...2 1 Hardware setup As indicated below from the IPEhub2 an Ethernet cable is then connected to the PC Hardware_Manual_M THERMO_96 IPETRONIK GmbH Co KG ipetronik com 7 30...

Страница 8: ...modules The configuration of the device is supported in the IPEmotion data acquisition software together with the IPETRON X PlugIn from release V10 00 00 The following diagram visualizes the cabling s...

Страница 9: ...up the cabling requirements are higher The cable 520 502 is providing the SUB D interface to the CAN card and M CAN T Junction is required to join the M CAN 9 pole connectors Hardware_Manual_M THERMO...

Страница 10: ...wing address I ipe connect local This web interface is a standard status interface where you have basic status information in the upper part In the lower pat you can define settings for the WiFi acces...

Страница 11: ...w is the all channel table instrument which provides readings for each channel In the factory configuration the first reading in the thermocouple voltage in micro Volts and in the second channel the r...

Страница 12: ...unit I Number The serial number printed on the name plate I Firmware Version of the firmware I Hardware Version of the hardware I Calibration Date Date of the last calibration I Adjust Date Date of t...

Страница 13: ...tion In the example blow you can see the drop down list to edit the Sensor mode You can switch from Voltage to one of the different Thermocouple types Hardware_Manual_M THERMO_96 IPETRONIK GmbH Co KG...

Страница 14: ...blow you can configure the Brake detection resistance The takes the internal resistance of the thermocouple line into account to adapter the brake detection sensitivity Hardware_Manual_M THERMO_96 IP...

Страница 15: ...3 2 Chanel Configuration You save the settings with green confirmation button in the bottom line Hardware_Manual_M THERMO_96 IPETRONIK GmbH Co KG ipetronik com 15 30...

Страница 16: ...system is organized in 6 separate blocks consisting of 16 channels each You can expand and collapse each block by sing the arrow buttons on the right hand side Hardware_Manual_M THERMO_96 IPETRONIK Gm...

Страница 17: ...s configured to connect to the access point of one Thermo scanner as defined in the setting of you mobile device In the case you have several thermo scanner online you need to switch in the mobile dev...

Страница 18: ...Tis work space is dedicated to check the software version of the web application and the build number in the About dialog All other functions are not relevant at this stage of the implementation Hard...

Страница 19: ...isualize the data of your device The default page consists of a tabulated overview Information All instrument and page configurations are stored on your local PC At this stage of implementation you ca...

Страница 20: ...and instrument configuration You need to navigate the PAGE work space in order to configure a page With the pencil tool you can access the Edit mode Hardware_Manual_M THERMO_96 IPETRONIK GmbH Co KG i...

Страница 21: ...iguration Then you can add any instrument which suits you display requirements You can also add several instruments and position the instruments via the docking windows Hardware_Manual_M THERMO_96 IPE...

Страница 22: ...le a Table instrument was created The Table instrument was chosen as it provides some special configuration functions developed for the M THERMO 96 which is related to the limit configuration Hardware...

Страница 23: ...4 Web display page and instrument configuration With the slider all signals you can add all channels to the instrument Hardware_Manual_M THERMO_96 IPETRONIK GmbH Co KG ipetronik com 23 30...

Страница 24: ...play page and instrument configuration You can activate for each unit type like temperature voltage and resistance a global threshold level Hardware_Manual_M THERMO_96 IPETRONIK GmbH Co KG ipetronik c...

Страница 25: ...y page and instrument configuration The limit configuration includes a lower and upper threshold value and an individual color can be selected Hardware_Manual_M THERMO_96 IPETRONIK GmbH Co KG ipetroni...

Страница 26: ...4 Web display page and instrument configuration The following screen shot is an example of limit color presentation Hardware_Manual_M THERMO_96 IPETRONIK GmbH Co KG ipetronik com 26 30...

Страница 27: ...4 Web display page and instrument configuration Below you have an example of a display page configuration with several instruments Hardware_Manual_M THERMO_96 IPETRONIK GmbH Co KG ipetronik com 27 30...

Страница 28: ...is available on the IPETRONIK website for download When you have installed the software you need to activate the IPETRONIK PlugIn X in the OPTIONS When you use the device in combination with the IPEmo...

Страница 29: ...ual device configuration As indicated below the device configuration follows the same structure as in the web interface Below the 2 CAN interfaces 3 channel blocks with 16 channels are listed For each...

Страница 30: ...lect a single channel you have access to the scaling tab sheet In there you can change the senor mode to thermocouple types or Voltage There are a lot more configuration function within IPEmotion For...

Отзывы: