IPCO STUDIO 3000 Скачать руководство пользователя страница 7

Specifications

Size

W - 220mm x H - 168mm x D - 80mm

Ambient 

0 to 50ºC maximum.

Supply

230V +/-15%

Thermocouple

Type R, S, K, or N.

(See ‘Configuration’ for change information)

Outputs

Single pole 3 Amp contacts. All outputs give 230V output via internal link.

(See ‘Electrical Connections’ if  isolated switching is required)

Display

R or S  -20ºC to +1600ºC, K or N 0 to 1300ºC
Ac/-3ºC over stated operational ambient.

Delay & Soak times 0 to 99 Hours 59 Minutes in one minute increments.
Ramp Rates

1 to 1000 ºC per Hour., “PASS”, or “FULL”

Setpoints

0 to maximum of display

(This depends upon thermocouple type selected.)
(will be limited by Setpoint limit - See below.)

Setpoint Limit

Adjustable over full display range.

Programs

10 (Except for single program version)
Pre loaded for convenience but all user modifiable.

Linking

On models MP/L,MP/E & MP/Z. 

Supplied By;-

Designed and manufactured by ;-

The Industrial Pyrometer Co Ltd

66/76 Gooch Street North, Birmingham, B5 6QY, England.

Tel: +44 (0) 121 622 3511   Fax: +44 (0) 121 666 6386

Содержание STUDIO 3000

Страница 1: ...mer and Temperature Controller which has been specifically designed for use with pottery kilns Control of the entire firing cycle is fully automatic to provide simply set accurate and repeatable firin...

Страница 2: ...it cannot be affected by the heat that will radiate during the firing of the kiln A removable bracket at the rear of the controller is used for fixing Slide the mounting bracket from the rear of the c...

Страница 3: ...lt During The Firing The display will normally show the temperature in the kiln The kiln LED is lit when power is being applied to the kiln The Slow LED Flashing is lit if the kiln is too slow to foll...

Страница 4: ...nce exists between zones during a firing then use the offset See Configuration to enter a value numerically opposite that being achieved e g If zone 2 is always 3OC above the main zone then enter 3 in...

Страница 5: ...en the main control output Terminal 1 should drive the slowest zone in the kiln Since the controller can only slow down the natural rate of rise of the kiln it is thus in the best position to keep the...

Страница 6: ...tructions define the way to operate the controller with this security active Configuration The controller operation may be modified to satisfy a variety of situations by amending the parameters This i...

Страница 7: ...bient Delay Soak times 0 to 99 Hours 59 Minutes in one minute increments Ramp Rates 1 to 1000 C per Hour PASS or FULL Setpoints 0 to maximum of display This depends upon thermocouple type selected wil...

Отзывы: