IPC Eagle Propane Powered Floor Care Equipment Скачать руководство пользователя страница 7

Using Propane Powered  

Floor Care Equipment 

All machines manufactured by Onyx Environmental Solutions 

come with a detailed Operator’s Manual.  Safety dictates 

that before using any new equipment, it is important that all 

operators read and understand the Operator’s Manual.

  

Basic Safety Guidelines Basic Safety Guidelines 

 

• Allow only qualified and trained personnel to operate equipment. 
• Follow maintenance and operating instructions.  
• Check oil level before starting. • Check oil level before starting. 
• Keep nuts and bolts tightened and hose connections snug.
• Never alter or reconstruct the fuel system.  To do so may be 
dangerous.  
• Use only UL, CTC/DOT listed cylinders, like the Onyx  
Environmental Solutions cylinder. 
• Store the fuel cylinder outside and away from heat and direct 
sunlight. 
• Never leave the machine running unattended. 
• Check pad holder for cracks each time the pad is changed. 
• Have the machine serviced by a Certified Technician, including an 
emission check, every three months. 
• Before attempting any service on the machine, turn the ignition 
switch OFF and remove the key to avoid accidental startup.
• Operate in a well-ventilated area. • Operate in a well-ventilated 
area.
• Keep hands and feet clear of rotating pads 
and brushes.
• Do not allow the floor care machine to operate without moving the 
machine.  It may burn the floor and damage the floor covering. 
• Only use replacement parts from the
manufacturer. 
• Post a Material Data Safety Sheet (MSDS) for propane. 

 

 

Propane Powered machines should not be used:  

• In nursing homes, hospitals, day-care centers, etc. 
• By unqualified or untrained personnel.  
• Unless properly maintained and adjusted  
• On areas with obstructions such as thresholds, floor outlet boxes, 
etc. 
• In areas where loose tiles or other objects
are present. 
• In rooms without proper ventilation. 

Operating Guidelines

Always read and understand the Operator’s Manual
for your machine before operating it.
  

Machine Inspection 

 

Regular maintenance of propane powered floor
care machines is a must to keep them in good, safe
working condition.  Every time the machine is used,
the following checkout procedure should be
followed. 

1. Check for overfilled cylinders.  Check cylinders, and vent if  
necessary.  Do this before taking the cylinder inside to use. 
Never take an overfilled cylinder inside. 
 
2. Check the recoil dust filter.  The recoil dust filter should be 
cleaned or replaced after each use of the machine and after each 
each use of the machine and after each hour of continuous  
operation.  If neglected, the engine will overheat and carbon
monoxide emissions will elevate.  hour of continuous operation.  If 
neglected, the engine will overheat and carbon monoxide  
emissions will elevate. 
 
3. Check the oil level.  The oil level should always be within the safe 
levels indicated on the dipstick.  Add oil if necessary, but never 
overfill.  Overfilling could cause irreparable damage to the engine.  

4. Check the condition of the pad or brushes and pad holder.  If the 
pad is dirty, it should be cleaned.  Flipping the pad and using
both sides will increase pad life.  If the pad is torn or worn down 
more than 1/8” (0.3 cm), it should be replaced.    
 
5. Enter checks in a daily maintenance log to maintain a detailed 
record for the machine.

Содержание Propane Powered Floor Care Equipment

Страница 1: ...Safety Manual for Propane Powered Floor Care Equipment...

Страница 2: ...ification 4 Propane Cylinders 4 EnviroGard Cylinders 4 Refueling Cylinders 4 Storing Cylinders 5 Transporting Cylinders 5 Using Propane Powered Floor Care Equipment 6 Basic Safety Guidelines 6 Operati...

Страница 3: ...t is also portable which makes it preferable over electric units for locations having few electrical outlets 4 Propane is extremely concentrated in it s liquid state One cubic foot of liquid propane w...

Страница 4: ...ement agencies such as the local Fire Marshall also rely on independent testing labs such as UL and CGA before giving their approval of the use of some equipment These labs thoroughly test equipment a...

Страница 5: ...ONITORING DRAGER Model 190 Manufactured by National Drager SENSIDYNE gas sampling system with YB 11038 Sensidyne dectector tubes DRAGER gas sampling system with YB 4620 Drager detective tubes GAS TECH...

Страница 6: ...to a propane dealer or to a job make sure the cylinders are securely fastened and stand ing in an upright position with the service valve closed A cylinder rattling around in the back of a vehicle and...

Страница 7: ...d In nursing homes hospitals day care centers etc By unqualified or untrained personnel Unless properly maintained and adjusted On areas with obstructions such as thresholds floor outlet boxes etc In...

Страница 8: ......

Отзывы: