BMA_77024-o16m-05_Rev2_en
IPAS GmbH, Hölscherstraße 27, D-47167 Duisburg
Mechanical data
REG casing 8TE:
Width:
Hight:
Lenght:
Weight
Mounting:
Plastic ABS – V0
144 mm
58 mm
90 mm
440 g
35 mm DIN rail
Electrical safety
Pollution class:
Protection type:*
Protection class:**
Overvoltage category:
KNX Bus:
2
IP20
III
III
SELV DC 30V
EMC
requirements
Complies with:
EMC directive 2014/30/EU
Environmental
conditions
Weather resistance:
Environmental con-
ditions in operation:
Storage emperature:
Transportation
temperature:
Rel. humidity:
(non condensing)
EN 50090-2-2
-5°C to +45°C
-25°C to +55°C
-25°C to +70°C
5 % to 93 %
Certification CE-
Signage
KNX registered:
According to EMC-
Guidelines:
Yes
(Residential and
commercial buildings),
Low Voltage guidelines
* (according to EN 60529); ** (according to IEC 1140)
Location and function of the LEDs and control elements
Mounting and wiring
As an REG device, the Power Block series are suitable for mounting in
distribution boxes on 35 mm DIN rails and wall boxes.
To mount the device, it must be angled to slide onto the DIN rail from
above and then locked into place with a downward movement.
Please make sure that the security latch at the bottom side of the
device snaps into place and that the device is firmly attached to the
rail. To dismount the device, the security latch can be pulled
downwards with a suitable tool and then the device can be removed
from the rail.
After the device has been inserted, the cables for the Outputs should
be attached to the upper and lower connectors. However, please make
sure that these are labelled clearly.
The power supply is connected to the bottom right-hand side
connector according to the order indicated on the casing. To connect
the KNX cable, a standard bus connector is plugged into the
respective entry on the device. Please make sure that there is double
basic insulation between the KNX installation and the power supply.
To do so, please insulate the wires of the KNX cable up to the bus
connector with the enclosed shrinkable tubing.
Please make sure that the cables are laid in a way that ensures
sufficient distance between the inputs and outputs cables.
5
4
6.1
6.2
2
1
3
7.3
144mm / 8 DIN RAIL
7.1
7.2
6.3
6.4
8
7.4
1
: KNX bus connector
2
: Programming button
3
: Programming LED
4
: SD card slot (only for internal use)
5
: Outputs connector: Channel A, B, C, D
6.1
: Manual control (See Annex 1)
Blind channel:
- Long press: Move Up (LED blinks while moving)
- Short press: Stop/Step
Binary channel:
- Short press: Output toggles to ON/OFF
FC Fan Speed:
- Short press: Fan Speed 1 is selected
6.2
: Manual control (See Annex 1)
Blind channel:
- Long press: Move Down (LED blinks while moving)
- Short press: Stop/Step
Binary channel:
- Short press: Output toggles to ON/OFF
FC Fan Speed:
- Short press: Fan Speed 2 is selected
6.3
: Manual control (See Annex 1)
FC Fan Speed:
- Short press: Fan Speed 3 is selected
6.4
: Manual control (See Annex 1)
FC Valve Output:
- Short press: Output valve toggles to ON/OFF
7.1
: LED output/channel status
Binary channel: LED ON = Output ON, LED OFF = Output OFF
Shutter: LED blinks while moving UP
Fan Coil (Type of Fan = Single):
-
LED ON = Fan Speed 1 ON
-
LED OFF = Fan Speed 1 OFF
7.2
: LED output/channel status
Binary channel: LED ON = Output ON, LED OFF = Output OFF
Shutter: LED blinks while moving DOWN
Fan Coil (Type of Fan = Single):
-
LED ON = Fan Speed 2 ON
-
LED OFF = Fan Speed 2 OFF
7.3
: LED output/channel status
Fan Coil (Type of Fan = Single):
-
LED ON = Fan Speed 3 ON
-
LED OFF = Fan Speed 3 OFF
7.4
: LED output/channel status
Fan Coil (Valve Output):
-
LED ON = Valve ON
-
LED OFF = Valve OFF
8
: Outputs connector: Channel E, F, G, H