1.  Push main cable through cable entry part of the wall 

bracket and ensure tight seal.

2.  Attach wall bracket. Pay attention of position „top“.  

Use the washer gaskets with rubberized face against  
to the wall bracket. Seal unused mounting holes.

3.  Establish ground connection and connect power lines.

4.  Hook light housing into notch of the wall bracket. 

Press luminaire to the wall bracket and tight set 
screws flush and evenly. Avoid pinched cables.

5.  Turn the protection cover of the sensor by 180° to the 

right.

6.  Time setting: before switching on power, turn the 

time-control anti-clockwise to min.. Switch on power. 
After 30 sec the sensor changes to stable working 
state. After turning off the light, check the function 
and switch on the light again. Provided that there is no 
continuous detection signal, the light should turn off 
within 5 sec.

cut control

instructions for use

7.  Lux setting: when the lux-control is turned anti-

clockwise to min and the unit is tested by daytime, the 
light should not turn on. Cover the detection window 
with an object (simulating night) and the light should 
turn on.

8.  If everything is set correctly, the time-control can be 

adjusted to set the lighting time and the lux-control to 
select the lux.

9.  Turn back the protection cover of the sensor by 180° 

to the left to protect the small adjusting wheels and to 
ensure the motion detection. 

lux-control

time-control

Отзывы: