background image

IOXUS, INC. 

  

 

18 

Stadium 

Circle 

Oneonta, NY 13820 

 

 

 

Toll Free: +1 877-751-4222 

Fax:   607-433-9014 

  http://www.ioxus.com 

[email protected]

   2/21/2019 

DOC 1-0004 Rev A 

© 2017 Ioxus, Inc. All rights reserved. 

 

Installation Guide and User Manual 

Model uST12D1100G31-ISA 

 

uSTART

®

 Medium Duty Vehicles Class 3 – 6 with 

12V Operating System 

Table of Contents

 

Model uST12D1100G31-ISA ..................................................................................................... 1

 

Safety ........................................................................................................................................... 2

 

Description ................................................................................................................................. 3

 

Feature Identification ........................................................................................................................................................... 3 

Unpacking ................................................................................................................................... 3

 

Installation .................................................................................................................................. 4

 

Maintenance Mode ............................................................................................................................................................... 4 
Mounting Location ............................................................................................................................................................... 4 
Pre-Installation Checks ....................................................................................................................................................... 4 
Installation .............................................................................................................................................................................. 5 
Wiring Diagrams .................................................................................................................................................................. 6 

Operation.................................................................................................................................... 7

 

Status.................................................................................................................................................... 7

 

Maintenance Mode .............................................................................................................................. 7

 

Run Mode ............................................................................................................................................. 7

 

Standby Mode ...................................................................................................................................... 8

 

Jump Start Mode ................................................................................................................................. 8

 

Fault Mode ........................................................................................................................................... 8

 

Bluetooth Connection ........................................................................................................................ 8

 

Flow Charts ......................................................................................................................................... 8

 

Run Mode ............................................................................................................................................................................... 9 
Maintenance Mode ............................................................................................................................................................ 10 
Jump Start Mode ................................................................................................................................................................ 11 

Maintenance ............................................................................................................................. 12

 

Troubleshooting ....................................................................................................................... 12

 

Содержание uSTART uST12D1100G31-ISA

Страница 1: ...Class 3 6 with 12V Operating System Table of Contents Model uST12D1100G31 ISA 1 Safety 2 Description 3 Feature Identification 3 Unpacking 3 Installation 4 Maintenance Mode 4 Mounting Location 4 Pre I...

Страница 2: ...r additional information Do not connect in reverse polarity uSTART is protected from reverse polarity in Maintenance Mode but sparks and arcing will occur if a reverse polarity connection is attempted...

Страница 3: ...of damage prior to unpacking Report any damage to the carton or the contents to the carrier immediately Retain all shipping materials until uSTART is fully inspected and determined to be operational...

Страница 4: ...x is near the Diesel Particulate Filter After Treatment System or any part of the exhaust mount uSTART in a location far away from it or install heat shielding capable of preventing uSTART from experi...

Страница 5: ...ery ies and uSTART in their appropriate locations When installing uSTART it is important to consider the battery hold down being used and how uSTART relates to any batteries being mounted with it uSTA...

Страница 6: ...1 877 751 4222 Fax 607 433 9014 http www ioxus com sales ioxus com 2 21 2019 DOC 1 0004 Rev A 2017 Ioxus Inc All rights reserved 6 Wiring Diagrams Figure 2 Typical wiring diagram before uSTART instal...

Страница 7: ...low LED indicates that it is in Maintenance Mode If uSTART is not connected to a battery it will still be in Maintenance Mode but the LEDs will be off If uSTART is not in Maintenance Mode when it is d...

Страница 8: ...ultracapacitors from a weak vehicle battery and provide power to jump start the vehicle Jump Start Mode can be accessed through the uSTART App The green LED will flash and the yellow LED will flash as...

Страница 9: ...Stadium Circle Oneonta NY 13820 Toll Free 1 877 751 4222 Fax 607 433 9014 http www ioxus com sales ioxus com 2 21 2019 DOC 1 0004 Rev A 2017 Ioxus Inc All rights reserved 9 Run Mode Figure 5 Run Mode...

Страница 10: ...Circle Oneonta NY 13820 Toll Free 1 877 751 4222 Fax 607 433 9014 http www ioxus com sales ioxus com 2 21 2019 DOC 1 0004 Rev A 2017 Ioxus Inc All rights reserved 10 Maintenance Mode Figure 6 Mainten...

Страница 11: ...m Circle Oneonta NY 13820 Toll Free 1 877 751 4222 Fax 607 433 9014 http www ioxus com sales ioxus com 2 21 2019 DOC 1 0004 Rev A 2017 Ioxus Inc All rights reserved 11 Jump Start Mode Figure 7 Jump St...

Страница 12: ...ive heat shield may be worth installing between a heat source and the uSTART An environmental condition above 65 C 149 F will cause uSTART to enter Fault Mode in order to protect the product Prolonged...

Страница 13: ...TART has detected an abnormal internal condition causing it to enter fault mode No LED s On 1 Standby Mode This is a normal condition uSTART will enter Run Mode automatically when the vehicle is start...

Отзывы: