background image

IOXUS 

 

 

 

18 Stadium Circle 

Oneonta, NY 13820 

 

 

 

Toll Free: +1 877-751-4222 

Fax:   607-433-9014 

  http://www.ioxus.com 

[email protected]

   2/17/2021 

DOC 1-0004 Rev B 

© 2021 Ioxus. All rights reserved. 

 

Standby Mode

 is indicated by all LED’s being 

off

 while connected to battery power

.

 uSTART

®

 operation can 

be confirmed by noting the change to a 

solid

 

green LED 

upon engine start, indicating a return to 

Run 

Mode.

 

Jump Start Charge Mode 

uSTART

®

 will automatically switch from 

Maintenance Mode

 to 

Jump Start Charge Mode

 if a vehicle’s 

battery charging system is active for more than 10 seconds. 

 

Jump Start Charge Mode

 also allows uSTART

®

 to charge up its ultracapacitors from a weak vehicle battery 

and provide power to jump start the vehicle.  

 

Jump Start Charge Mode 

can be 

accessed through the uSTART

®

 App. The 

green LED

 will be 

solid

 and the 

yellow LED

 

will 

flash

 as uSTART

®

 charges its ultracapacitors. After the charging period finishes, the 

green 

LED

 

will 

be solid

,

 

indicating that the vehicle is ready to be started. Start the vehicle immediately for best 

results. See the uSTART

®

 App User Manual for additional details. 

 

Fault Mode 

uSTART

®

 has experienced an abnormal condition or fault, indicated by a 

solid red LED

. See the 

Troubleshooting section for more information.  

Bluetooth Connection 

uSTART

®

 is connected via Bluetooth when the 

blue LED

 is lit solid. See the uSTART

®

 App User Manual for 

more details (note that the blue LED may be difficult to see in bright locations, shading the status LED area 
may help with seeing it). 

Flow Charts 

The below flow charts can be utilized for the most common scenarios of use: Installation, preparation for 
service and use during a jump start attempt.  

 

Содержание uST12V0375G31-MDA

Страница 1: ...Contents Model uST12V0375G31 MDA 1 Safety 2 Description 3 Feature Identification 3 Unpacking 3 Installation 4 Maintenance Mode 4 Mounting Location 4 Pre Installation Checks 4 Installation 4 Wiring Dia...

Страница 2: ...al information Do not connect in reverse polarity uSTART is protected from up to 28 VDC reverse polarity in Maintenance Mode but sparks and arcing will occur if a reverse polarity connection is attemp...

Страница 3: ...damage prior to unpacking Report any damage to the carton or the contents to the carrier immediately Retain all shipping materials until uSTART is fully inspected and determined to be operational uSTA...

Страница 4: ...st the vehicle starting and charging system prior to installing uSTART to isolate any pre existing problems Refer to Recommended Practice 129A RP 129A of the American Trucking Association ATA Technolo...

Страница 5: ...TART relates to any batteries being mounted with it uSTART is designed to be installed using the existing Group 31 battery hardware Install uSTART using the existing Group 31 battery hardware and torq...

Страница 6: ...1 877 751 4222 Fax 607 433 9014 http www ioxus com sales ioxus com 2 17 2021 DOC 1 0004 Rev B 2021 Ioxus All rights reserved 6 Wiring Diagrams Figure 2 Typical wiring diagram before uSTART install Fi...

Страница 7: ...lways be in Maintenance Mode prior to any maintenance If uSTART is connected to a battery the solid yellow LED indicates that it is in Maintenance Mode If uSTART is not connected to a battery it will...

Страница 8: ...Charge Mode can be accessed through the uSTART App The green LED will be solid and the yellow LED will flash as uSTART charges its ultracapacitors After the charging period finishes the green LED will...

Страница 9: ...ights reserved 9 Installation and Startup Figure 5 Installation Flow Chart uSTART installed and connected to battery MAINTENANCE Mode Solid Yellow LED Start Vehicle and wait 10 Seconds or Switch to RU...

Страница 10: ...reserved 10 Disconnecting uSTART for Service Figure 6 Service Flow Chart Disconnect uSTART Positive Terminal and wait 7 seconds uSTART Previously Installed Solid Green LED RUN Mode Or All LEDs Off St...

Страница 11: ...se uSTART App to put uSTART into JUMP START CHARGE Mode uSTART Previously Installed but vehicle failed start attempt Load may be pulling down Vehicle voltage Shut off All loads and wait for voltage 10...

Страница 12: ...ngine cranking times will cause uSTART to enter fault mode in order to ensure long term product lifetime is not reduced 3 Malfunction Protection The fault condition will not automatically clear and th...

Страница 13: ...ly checked for oxidation or loose connections and cleaned or tightened as necessary No other maintenance is required Poor electrical connections can cause performance problems with uSTART Prior to rem...