background image

IOXUS 

 

 

 

18 Stadium Circle 

Oneonta, NY 13820 

 

 

 

Toll Free: +1 877-751-4222 

Fax:   607-433-9014 

  http://www.ioxus.com 

[email protected]

   2/17/2021 

DOC 1-0004 Rev B 

© 2021 Ioxus. All rights reserved. 

 

Operation 

Status 

The 

Status LEDs

 indicate uSTART

®

 operation mode.  The 

green

 

and 

yellow LEDs

 

indicate the mode.  The 

red LED

 

indicates there is an error. The 

blue LED

 

indicates a Bluetooth connection to the module. Refer to 

Figure 4 for 

Status LED

 states. 

Mode 

GREEN LED 

YELLOW LED 

RED LED 

Description 

Maintenance 

OFF 

SOLID 

OFF 

uSTART® is connected. 

There is no energy at the terminals 

Jump Start Charge 

SOLID 

*FLASH* 

OFF 

uSTART® is charging for the first time  

or charging for a Jump Start 

Run 

SOLID 

OFF 

OFF 

uSTART® is active 

Standby 

OFF 

OFF 

OFF 

uSTART® is asleep 

Fault 

OFF 

OFF 

SOLID 

uSTART® is experiencing a fault. 

Please see user manual for instructions 

Figure 4: uSTART® Status LED States

 

Maintenance Mode 

In 

Maintenance Mode

, uSTART

®

 terminals are not energized. It is safe to handle and work on when it is in 

this mode. uSTART

®

 should always be in 

Maintenance Mode 

prior to any maintenance. 

If uSTART

®

 is connected to a battery, the 

solid yellow LED

 indicates that it is in 

Maintenance Mode

. If 

uSTART

®

 is not connected to a battery it will still have the protections of 

Maintenance Mode

, even when 

the LEDs are 

off

.  

If uSTART

®

 is not in 

Maintenance Mode

 when it is disconnected from a battery, it will automatically switch 

to 

Maintenance Mode

 within 7 seconds. 

Run Mode 

uSTART

®

 is on and actively maintaining the vehicle’s voltage while in 

Run Mode

.  It can support engine 

cranking currents for a few seconds or support vehicle loads for many seconds to several minutes. It is not 

safe to handle or work on uSTART

®

 when it is in 

Run Mode.

 

 

Run Mode

 is indicated by a 

solid

 

green LED

.

    

 

Standby Mode 

If uSTART

®

 is in 

Run Mode

 and a vehicle’s battery charging system

 

has been inactive for more than 1 hour, 

uSTART

®

 will automatically enter 

Standby Mode 

in order to reduce energy consumption

.

 If at any time 

uSTART

®

 detects a significant, rapid change in the voltage level (as will occur during engine start), uSTART

®

 

will automatically return to 

Run Mode

 and support the engine cranking event. It is not safe to handle or work 

on uSTART

®

 when it is in 

Standby Mode.

 

Содержание uST12V0375G31-MDA

Страница 1: ...Contents Model uST12V0375G31 MDA 1 Safety 2 Description 3 Feature Identification 3 Unpacking 3 Installation 4 Maintenance Mode 4 Mounting Location 4 Pre Installation Checks 4 Installation 4 Wiring Dia...

Страница 2: ...al information Do not connect in reverse polarity uSTART is protected from up to 28 VDC reverse polarity in Maintenance Mode but sparks and arcing will occur if a reverse polarity connection is attemp...

Страница 3: ...damage prior to unpacking Report any damage to the carton or the contents to the carrier immediately Retain all shipping materials until uSTART is fully inspected and determined to be operational uSTA...

Страница 4: ...st the vehicle starting and charging system prior to installing uSTART to isolate any pre existing problems Refer to Recommended Practice 129A RP 129A of the American Trucking Association ATA Technolo...

Страница 5: ...TART relates to any batteries being mounted with it uSTART is designed to be installed using the existing Group 31 battery hardware Install uSTART using the existing Group 31 battery hardware and torq...

Страница 6: ...1 877 751 4222 Fax 607 433 9014 http www ioxus com sales ioxus com 2 17 2021 DOC 1 0004 Rev B 2021 Ioxus All rights reserved 6 Wiring Diagrams Figure 2 Typical wiring diagram before uSTART install Fi...

Страница 7: ...lways be in Maintenance Mode prior to any maintenance If uSTART is connected to a battery the solid yellow LED indicates that it is in Maintenance Mode If uSTART is not connected to a battery it will...

Страница 8: ...Charge Mode can be accessed through the uSTART App The green LED will be solid and the yellow LED will flash as uSTART charges its ultracapacitors After the charging period finishes the green LED will...

Страница 9: ...ights reserved 9 Installation and Startup Figure 5 Installation Flow Chart uSTART installed and connected to battery MAINTENANCE Mode Solid Yellow LED Start Vehicle and wait 10 Seconds or Switch to RU...

Страница 10: ...reserved 10 Disconnecting uSTART for Service Figure 6 Service Flow Chart Disconnect uSTART Positive Terminal and wait 7 seconds uSTART Previously Installed Solid Green LED RUN Mode Or All LEDs Off St...

Страница 11: ...se uSTART App to put uSTART into JUMP START CHARGE Mode uSTART Previously Installed but vehicle failed start attempt Load may be pulling down Vehicle voltage Shut off All loads and wait for voltage 10...

Страница 12: ...ngine cranking times will cause uSTART to enter fault mode in order to ensure long term product lifetime is not reduced 3 Malfunction Protection The fault condition will not automatically clear and th...

Страница 13: ...ly checked for oxidation or loose connections and cleaned or tightened as necessary No other maintenance is required Poor electrical connections can cause performance problems with uSTART Prior to rem...