Страница 1: ...an The unit should be screwed to a solid surface firmly enough to hold its weight during ve hicle operation V ELECTRICAL CONNECTIONS A Attach an 8 gauge chassis ground wire to the transfer switch grou...
Страница 2: ...h circuit to 5 and 6 Connect the designated circuit panel to the output terminals The inverter will only supply the load in the ab sence of the 50 amp power supply in which case only the load designat...
Страница 3: ...s are affected by this The compressor will try to start the voltage will drop which will cause the contactor to drop out at which point the voltage will rise to the pre inrush level The contacts will...
Страница 4: ...ed cir cuit is isolated Repair the fault and retest The hi pot test is successful when there are no more fault indications GENERATOR NOTE It is never advisable to start or stop a generator under load...