INSTALLATION GUIDELINES

MOUNTING LOCATION

The IOTA Power Converter/Battery Charger can be 
mounted in any position within an enclosed or interior 
compartment. Provide sufficient air space to allow unre-
stricted airflow in and around the unit. Provide at least 4

 

around the fan of the DLS-X to allow for proper air intake.

IF USING AN OPTIONAL MOUNTING PLATE - 

Attach 

the mounting plate to the mounting location prior to  
attaching the unit.

DO NOT

 mount the unit in a zero clearance compartment. 

DO NOT 

mount the DLS-X in the same compartment with 

flammable items such as gasoline or batteries. There are 
no components within the DLS-X unit that, during normal 
operation, produce arcs or sparks. However, all electronic 
devices have some potential for generating sparks in 
the event of failure which can result in explosion or fire.

DO NOT

 mount the DLS-X in an area that has the 

potential of dust, debris, or other foreign materials to 
enter in through the DLS-X vents. 

DO NOT

 place the DLS-X directly above the battery; the 

gases from the battery can corrode and damage the DLS-X.  

IOTA DLS-X Series Power Converter/Battery Chargers 
convert 120 volts nominal A.C. to 13.6 volts D.C. As a 
power supply, its tightly controlled regulation allows the 
user to operate any 12 volt nominal D.C. load up to the 
converter’s rated output current. As a battery charger, the 
converter will maintain the battery, delivering its full-rated 
current when the battery capacity falls sufficiently low. 
The voltage is set to deliver its maximum current for the 
necessary period of time that minimizes undue stress 
to the battery caused by heating of its cells. This helps 
to ensure the longest possible life of the battery. Over 
time, as the battery nears its full capacity, the converter 
will float-charge the battery to prevent self-discharge of 
its cells.  

PROTECTION FEATURES

The IOTA Power Converters/Battery Chargers are 
designed with high quality components to help ensure 
years of continuous use. The unit is protected by mul-
tiple protection features for a long, trouble-free life.

1) 

Reverse Battery Polarity Protection.

 2) 

Brown-Out 

Input Protection.

 3) 

Over-Current Protection

 - cycle by 

cycle peak limiting as well as rated current limiting to 
maximize the life of the converter. 4) 

Over-Temperature 

Protection. 

In addition, it is designed with a unique 

“proportional” fan control circuit. Fan speed is directly 
proportional to the converter’s internal ambient tem-
perature. This enables the fan to turn on and off very 
slowly, minimizing unwanted fan-starting noise. 

The IOTA DLS-X Series Power 
Converters/Battery Chargers are 
warranted from defects in materi-
als or workmanship for three years 
from date of retail purchase, and 

limits the remedies to repair or replacement. This warranty is 
valid only in the continental United States and Canada. For 
complete warranty details, contact Customer Service or visit  
www.iotaengineering.com.

WARRANTY

PRODUCT DESCRIPTION

W A R R A N T Y

REPAIR

REPLACEMENT

T H R E E - Y E A R

INSTALLATION GUIDELINES  

(cont.)

BATTERY CONNECTION

Before you connect the DLS-X to the battery, make sure that 
the AC power cord is NOT plugged into an electrical outlet.
Disconnect the positive side of the battery before installation. 
Connect the positive and negative terminal lugs to battery or 
load. Always use the proper size wire based on the amperage 
of the converter and the battery. Torque the connections to the 
proper rating according to the wire manufacturer’s specifica-
tions. Refer to Illustration 1. Recreational vehicle applications 
require a type III circuit breaker be installed within 18

 

of the 

battery, connecting the battery positive to the line side of the 
breaker, and the IOTA unit to the load side. Connect “Chas-
sis Bonding Lug” on the IOTA unit to vehicle chassis or other 
grounding source. Refer to Illustration 1.

120 VOLT A.C. INPUT

 

Plug the unit A.C. input cord into an appropriate 120-volt 3-wire 
grounded source. The blue LED indicator light will illuminate, 
indicating the presence of AC power. Refer to Illustration 2 for 
specifications of the cord provided with your DLS-X unit. See the 
Technical Specifications Chart on page 4 for maximum current 
draw and required input voltages.
DO NOT USE EXTENSION CORDS - Using an improper 
extension cord could result in a risk of fire and electric shock, 
and may result in property damage, personal injury or death.
DO NOT OPERATE THE DLS-X WITH A DAMAGED CORD 
OR PLUG. Have the cord or plug replaced immediately by 
qualified service personnel.

REVERSE POLARITY FUSES

The IOTA Battery Charger/Power Supply is protected against 
reverse polarity on the DC output. If a battery or the unit is 
hooked up incorrectly, the fuses will blow and can be easily 
replaced. Always use the same size and style fuse that came 
with the converter.

NOTE: Depending on the amperage model of the DLS-X, 
fuses may not be present in all slots. Refer to the chart 
below for the rating and number of fuses per model:

DLS-15-X
DLS-30-X
DLS-45-X
DLS-55-X
DLS-75-X
DLS-90-X

Model

Fuse Rating

Fuse Quantity

7.5A

15A
25A
20A
25A
30A

2
2
2
3
3
3