STOP!!!
Read the Instruction
BEFORE
setting up and using the mount! Worm/gear system damage due to improperly
use will not be covered by warranty.
Questions? Contact us at
Instruction for CEM120 Gear Switch and Axle Locking Knob
Both RA and DEC have the same Gear Switch and Axle Locking Knob, the operations are the same.
Gear Switch
Axle Locking Knob
As an example, here are the positions for the Gear Switch and Axle Locking Knob for RA axis:
Fig.1:
When transferring or installing the mount, lock the Axle Locking Knob
and disengage the Gear
Switch . So the RA won’t swing and there is no force applied onto the worm/ring gear.
Fig.2:
During mount balancing process, pull and turn the Axle Locking Knob to release it
and leave the
Gear Switch at disengaged position . Now the mount will swing freely in RA direction.
Fig.3:
During normal operation of the mount,
i.e.,
GOTO and tracking, turn the Gear Switch to locking position
to engage the worm/ring gear while leave the Axle Locking Knob released
Fig.1
During transferring and
installing…
Fig.2 During balancing…
Fig.3
During operating…
ONLY
set the Gear Switch at locking position to engage the worm/ring gear during goto, slew or tracking.
ALWAYS
lock the Axle Locking Knob during transferring and installing.
DO NOT
lock both Gear Switch and Axle Locking Knob at the same time.