iOptron AccuAligning Скачать руководство пользователя страница 6

 

Figure 10. Polar Scope Dial 

 

Figure 11. Zero position mark 

 

5.  Release R.A. Clutch Screw. Press the LFTT or RIGHT button on the hand controller to rotate 

the polar scope 

to align the 12 o’clock position of the dial on the top, as shown in Figure 10. (Or 

align to the zero position mark on the R.A. unit as shown in Figure 11). You may press number 
9 button to change the rotation speed to MAX.  

6.  Make sure that the time and site information of the hand controller is correct. Press the 

MENU

 

button, then select “

Align

” and “

Pole Star Position

” to display the current Polaris position.  For 

example,  on  May  30,  2010,  20:00:00  in  Boston,  United  States  (Lat  N

42º30’32”  and  Long 

W

71º08’50”, 300 min behind UT, DST set to Y), the Polaris Position is 1hr 26.8m and r = 41.5m, 

as shown in Figure 12 (a). 

7.  Adjust  the  mount  in  altitude  (latitude)  and  azimuth  (heading)  direction  to  place  Polaris  in  the 

same position on the Polar Scope Dial as indicated on the HC LCD. In this case, the Polaris will 
be located at a radius of 

41.5’ and an angle of 1 hour 26.8 minute, as shown in Figure 12 (b).  

 

(a) 

 

 

 

 

 

 

(b) 

Figure 12. Place the Polaris at the position as shown on hand controller 

 

You need to loose Azimuth Lock a little and use Azimuth Adjustment Knobs to adjust the mount 
in azimuth (heading) direction (Figure 13). Unlock Latitude Clutch, and turn Latitude Adjustment 
Screw or push the mount down to adjust the altitude (latitude), as shown in Figure 14. Secure 
all the locks after the polar alignment is done.  

Now the mount is polar aligned. 

Содержание AccuAligning

Страница 1: ...iOptron Corporation 6E Gill Street Woburn MA 01801 www iOptron com AccuAligningTM Polar Scope for SmartEQTM Portable German Equatorial GOTO Mount Installation and User Manual Product 3130...

Страница 2: ...1X Polar scope illumination LED 2X M3 screw and nut Figure 1 Parts list Installation Install polar scope 1 Unscrew polar scope cover from the mount 2 Insert included M4 set screw into the treaded hol...

Страница 3: ...ation LED 1 If there is a bar in the middle of the polar alignment opening as shown in the Figure 4 the SmartEQ mount already has an illumination LED as part of the main control board If you can t see...

Страница 4: ...3 Carefully pull the face plate open Disconnect the RA and DEC motor drive cables first Then disconnect two battery holders from the main board 4 Remove the main control board from the face plate Ali...

Страница 5: ...o the battery packs or connect the mount with an AC DC power adapter Plug the Go2Nova hand controller into the mount HBX port Turn the power switch on 2 Make sure that the DEC axle is not blocking the...

Страница 6: ...30 32 and Long W71 08 50 300 min behind UT DST set to Y the Polaris Position is 1hr 26 8m and r 41 5m as shown in Figure 12 a 7 Adjust the mount in altitude latitude and azimuth heading direction to p...

Страница 7: ...putting a star in the center of the polar scope reticle cross hairs and rotating mount s R A axis If the star stays in the center of cross hairs the polar scope is aligned to the mount s R A axis In t...

Страница 8: ...reticle or PLASTIC holder Only loose tighten one screw at a time and a few turns each time to avoid the reticle totally lost its position It may take a few minutes to familiarize yourself with the sc...