background image

SLEEP MODE

When set to

 SLEEP

, the IONMAX Humidifier ION90 LCD becomes dimmer with the relative humidity 

set at 60%. It will operate continuously for 8 hours with 

WARM

 on before powering off automatically.

WATER SHORTAGE INDICATOR

The IONMAX Humidifier ION90 comes with an inbuilt water shortage sensor that will inform you when 

the water level is low. The unit will beep 5 times and the         will blink continuously to alert you of the 

status. This is useful in reminding the user to refill the 

Water Tank

.

DEMINERALIZATION FILTER

When water goes through the Demineralization Filter, it is restructured at an ionic level and the dissolved 

mineral salts and other additives are removed, thereby softening the water. This aids in reducing mineral 

buildup at the nebulizer and finer ultrasonic humidification.

USING THE IONMAX HUMIDIFIER

Ensure that the power cord is removed from the power supply at all times during installation, 

refilling of water, maintenance and transportation.

OPERATING NOTICE

Remove the unit from all packaging. Check and ensure 

that there are no foreign objects inside the 

Water Tank

 and 

Water Reservoir

.

Remove the 

Water Tank

 from the base and fill it with clean, 

tepid or cool water from the tap. 

NOTE: 

DO NOT use water 

above 40°C.

Empty water from base.

Fasten the cap of the 

Water Tank

 snugly and place it back 

onto the 

Humidifier  Base

. Please note that whenever a 

filled 

Water Tank 

is placed onto the 

Humidifier Base

, the 

sound of gurgling water is normal. This happens when water 

is travelling from the 

Water Tank 

into the 

Water Reservoir

Wait for a while for the water to fill up the 

Water Reservoir

.

Step 1:

Step 2:

Step 3: 

Step 4:

7

Содержание ION90

Страница 1: ...ionmax com au 1300 800 200 ...

Страница 2: ...USER MANUAL Updated 07 08 2013 Version 2 1 ION90 HYBRID UV HUMIDIFIER ...

Страница 3: ... for purchasing the Ionmax Ion90 Hybrid UV Humidifier The Ion90 reintroduces moisture into the air to help you maintain a comfortable humidity level in your home Utilising a combination of UV LED and Bio photocatalyst technology the Ion90 sterilises and deodorises the air before allowing it to emit clean pure mist Please read this manual carefully to ensure proper usage and save these instructions...

Страница 4: ...PRODUCT DESCRIPTION Hybrid UV Humidifier ION90 2 ...

Страница 5: ...to Catalyst Cool Mist 40W Warm Mist 125W UV LED Light 1W Up to 16m 6 5 litres Cool Mist 300 ml hr Warm Mist 400 ml hr Cool Mist Minimum 21 hr Warm Mist Minimum 16 hr 3 5 kg 180mm w x 260mm d x 315mm h LED Display Screen Humidity Status Humidifier Settings Auto Mode UV Bio Photocatalyst Sterilization and Deodorization Dual Mist Outlet Duo Humidification Methods Humidity Level Control Humidification...

Страница 6: ...oom indoor Ideal Humidity Level indoor Outdoor Humidity Level RH 30 40 60 70 70 95 Recommended by the Guideline for Good Indoor Air Quality Why use Ultrasonic Technology for humidification Ultrasonic Technology is an extremely effective and economical method of maintaining and moderating the relative humidity level in the surrounding air Ultrasonic Technology works in soundless operation and creat...

Страница 7: ... the IONMAX Humidifier ION90 has two mist outlets which can be rotated accordingly to your surrounding for optimal efficiency DUO HUMIDIFICATION METHODS The IONMAX Humidifier ION90 has the capability to use two types of humidification methods Heat Vapourizing Warm Mist and Ultrasonic Humidification Cool Mist Both methods utilise ultrasonic vibrations It is recommended to use the Warm Mist option i...

Страница 8: ...l PROGRAMMED HUMIDITY SETTINGS Common Cold In this mode the IONMAX Humidifier ION90 will maintain the relative humidity from 56 to 70 RH It helps to keep the relative humidity high for better breathing as well as to alleviate cold symptoms Atopy IONMAX Humidifier ION90 is also able to help people with Atopy by maintaining the relative humidity from 50 to 62 at an increment of 2 This range of relat...

Страница 9: ...educing mineral buildup at the nebulizer and finer ultrasonic humidification USING THE IONMAX HUMIDIFIER Ensure that the power cord is removed from the power supply at all times during installation refilling of water maintenance and transportation OPERATING NOTICE Remove the unit from all packaging Check and ensure that there are no foreign objects inside the Water Tank and Water Reservoir Remove ...

Страница 10: ... Casing The IONMAX Humidifier ION90 should always be regularly maintained and cleaned For external maintenance regularly use a damp cloth to wipe the surface to prevent the accumulation of dust To Clean The Water Tank Remove sediments or scale buildup by shaking the Water Tank vigorously after refilling the Water Tank Pour out the water and wipe the internal tank thoroughly with a soft cloth To Cl...

Страница 11: ...maintenance of humidifier Remove all existing water in the tank and base clean with fresh water and refill with fresh water No Water Indicator lits up despite sufficient water Water Level Sensor float stuck Unit not sitting level Gently release Water Level Sensor float TROUBLESHOOTING WARNING AND PRECAUTIONS DO NOT add any additives into the Water Tank unless specified DO NOT use any detergents so...

Страница 12: ...line the humidifier during operation DO NOT pour water directly into the Mist Outlet Fill water only through the Water Tank DO NOT handle the humidifier or power cord with wet hands DO NOT immerse the humidifier base into water Always unplug the humidifier during installation refilling of water maintenance and transportation DO NOT place humidifier under direct sunlight high temperature near compu...

Страница 13: ...re not advised to operate the humidifier or are only advised to operate it under supervision 3 Only operate the humidifier when it is completely assembled 4 Always ensure that there is sufficient water in the Water Tank before operation 5 Use only clean tepid or cool water to fill the tank 6 DO NOT use Essential Oil 7 Always have the Mist Outlet and Water Tank in place while the unit is operating ...

Страница 14: ...refill the unit only when the empty light comes on as the base will already be empty Condensation Occasionally water may pool at the base of the unit due to condensation build up which may make the unit to appear to be leaking This can occur when the air temperature drops as warm air holds more water than cold air Switching from cool to warm mist increases the air temperature slightly Reduce the h...

Страница 15: ...chase docket or a copy or receipt must be presented with the warranty when making a claim under this warranty Service during the Warranty Period To claim for warranty contact us on 1300 800 200 or info andatech com au to get an RA Return Authorization Number Ensure that the RA is clearly stated on the outside of the packaging and that the product is properly packaged so that no damage occurs to th...