General
F
unction
1. In case of a forcible attempt to open the door from outside without entering P/W or
contacting the registered card (electronic key), a strong warning sound is given.
2. How to cancel the warning sound
1) When you know the P/W, press the *(Start) button, enter the P/W, then press the
*(Start) button once again. The warning sound will be cancelled.
2) By contacting the registered cards (electronic keys), you can cancel the warning
sound.
9-7 Alarm Function for forcible entry
When you leave the house in Manual mode, you will hear three beeps (
“
b
be
ee
ep
p b
be
ee
ep
p
b
be
ee
ep
p
”
) one second after closing the door unless you switch it to
“
C
CL
LO
OS
SE
E
”position.
The beeping sound is the notification of Manual mode.
9-8 Function for notification of Manual mode
9-9 Functions for coping with the malfunction
of the Open/Close Sensor
1. With the door closed, when the Open/Close sensor is not functioning
1) The warning sound of forcible entry is given.
2) Cancel the warning sound using P/W or the registered card keys (electronic keys).
3) Switch the door lock to the Manual mode and use the product.
2. With the door open, when the Open/Close sensor is not functioning
1) At the moment, you cannot switch the door to
“
C
CL
LO
OS
SE
E
”position.
2) Switch the door lock to the Manual mode and use the product.
3. In case of a malfunction of the Open/Close sensor, use the product in the Manual
mode at first, and then apply for after-sales service.
When the door is not open in the Auto mode, if you turn the Manual OPEN/CLOSE
Device toward
“
C
CL
LO
OS
SE
E
”position, the door will be automatically open with a warning
sound by the function for Dead Bolt protection.
B
Be
e c
ca
arre
effu
ull n
no
ott tto
o h
ha
av
ve
e tth
he
e D
De
ea
ad
d B
Bo
olltt b
brro
ok
ke
en
n b
be
ec
ca
au
us
se
e tth
hiis
s ffu
un
nc
cttiio
on
n iis
s n
no
ott w
wo
orrk
kiin
ng
g iin
n
tth
he
e M
Ma
an
nu
ua
all m
mo
od
de
e a
an
nd
d u
un
nd
de
err tth
he
e s
stta
atte
e o
off
“
“L
Lo
oc
ck
k”
”o
off tth
he
e D
Du
ua
all L
Lo
oc
ck
kiin
ng
g S
Sw
wiittc
ch
h..
9-10 Function for Dead Bolt protection
4) 9V battery is 6F22 (FC-1), available on the market.
5) When using 9V battery, accurately put the battery to the outside power source
terminal and use the P/W or Card.
- If the battery is placed properly, the red LED on the right side of the outside