Submersible Sump Pump

OPERATION MANUAL

Dated: 05/20/2016

Document Name: SH50_OM

Page 2 of 4

www.ionproducts.net

4.  Use steel or plastic pipe for all connecting lines 

between pump and sewer outlet. 

Note:

 Some city regulations do not allow installing a 

pump with plastic pipe. Check local regulations.

5. 

Drill a 1/8″ inch hole into discharge pipe 4 inches 

above the pump’s discharge.  

6.  A check valve should be installed in discharge 

pipe, above the cover of the basin.

7.  Connect to power source using 3-prong 

grounded 115 volt AC receptacle. Do not remove 

ground pin from electrical plug. Do not use an 

extension cord.

8.  Use pump submerged for sump, dewartering 

applications (temperature to 120° F).

9.  In applications where the pump may sit idle for 

months at a time, it is recommended that the 

pump(s) be cycled every few months to ensure 

the pumping system is working properly when 

needed.

10.  An audible alarm for high water conditions 

should be installed for additional protection 

against high water conditions.

Your pump warranty is void...

If...power cord has been cut.

If...pump has been used to pump mud, cement, 

tar, abrasives or chemicals.

If...pump has been used for pumping hot water 

(above 120°F ).

If...cord tag has been removed.

Servicing should be performed only by an authorized 

service center.

WARNING:

 Always disconnect the pump from 

power source before handling or making any 

adjustments. Always wear rubber boots when 

there is water on the floor and you must unplug the 

pump or make any adjustments.

P

umP

 S

ervicing

Note: 

Automatic thermal overload protects the sealed-

in-oil motor. Running dry may overheat the motor and 

activate the overload protector until the unit cools.

Pump does not run or just hums.

1.  Line circuit breaker may be off, blown or loose.

2.  Cord prong may not be making contact in 

receptacle.

3.  If all symptoms check okay, motor winding may 

be open; take to authorized service center for 

check.

Pump runs but does not deliver water.

1.  Check valve may be installed backward. Arrow 

on valve points in direction of flow.

2.  Discharge gate valve, if used, may be closed.

3.  Pump may be air locked. Start and stop several 

times by plugging and unplugging cord. Check 

vent hole in pump case for plugging. 

4.  Ion

®

 Technologies pumps have a small air vent 

hole in the impeller cavity to let out trapped air. If 

this hole becomes plugged, pump may air lock. 

To break the air lock, use a small screwdriver to 

clear hole in the impeller cavity.

5.  As a secondary precaution in installations of this 

type – 

1

/

16

″ hole should be drilled in the discharge 

pipe below the check valve. The check valve 

should be installed in pump discharge above the 

cover on the basin.

Note: 

In sumps where the pump is operating daily, air 

locking rarely occurs.

1.  Pump head may be too high. Pump cannot 

deliver water over 33

'

  vertical  lift.  Horizontal 

distance does not affect pumping, except for 

friction loss through the pipe.

2.  Inlet in pump base may be clogged. Remove 

pump and clean out openings.

3.  Impeller or volute openings may be plugged or 

partially plugged. Remove pump and clean out.

t

roubleShooting