death.
CAUTION:
These pumps are NOT to be
installed in locations classified as
hazardous in accordance with the National Electric
Code, ANSI/NFPA 70.
WARNING:
Do not introduce into any sewer,
either directly, or through a kitchen waste
disposal unit or toilet: Seafood Shells, Aquarium
Gravel, Cat Litter, Plastic Objects, Sanitary
Napkins or Tampons, Diapers, Rags, Disposable
Wipes or Cloth, Medications, Flammable Material,
Oil or Grease, Strong Chemicals, Gasoline.
• Operation against a closed discharge valve will
cause premature bearing and seal failure on
any pump.
• Any wiring of pumps should be performed by a
qualified electrician.
• Cable should be protected at all times to avoid
punctures, cuts, bruises, and abrasions-inspect
frequently.
• Never handle connected power cords with wet
hands.
• Never let cords or plugs lie in water outside the pit.
•
These pumps are offered in a three phase and
single phase wiring configuration. Voltages will
vary according to the application and can be seen
in the tables in this manual.
Pump Installation
These important instructions must be followed for
satisfactory performance of your pump. Before
installation, check your local electrical and plumbing
codes.
The sump or basin shall be sealed and vented in
accordance with local plumbing codes. This pump is
designed to pump domestic wastewater, nonexplosive
and noncorrosive liquids and shall NOT be installed in
locations classified as hazardous in accordance with
the National Electrical Code (NEC) ANSI/ NFPA 70
or Canadian Electric Code (CEC). The pump should
never be installed in a trench, ditch, or hole with a dirt
Capacity (GPM)
Total Dynamic Head (ft.)
0
10
20 30
40
50
60
70
80
90
45
40
35
30
25
20
15
10
Dimensions
Performance
?
2”FNPT
13.7”
4.2”
4.8”
7”
9.8”
5