background image

Ion Technologies ES45

Effluent Pump

OPERATION MANUAL

Dated: 11/22/2017

Document Name: ES45_OM.indd

Page 1 of 11

www.ionproducts.net

Introduction

Thank you for purchasing an Ion Technologies effluent 

pump. Take the time to read the instructions carefully 

before using this appliance. We strongly recommend 

that you keep this instruction manual in a safe place 

for future reference. 

Check the nameplate for your pump’s specification, 

refer to the table list.

Be careful not to exceed the given specifications in 

the use of your pump.

Each pump is individually factory tested to ensure 

proper performance. Closely following these 

instructions will eliminate potential operating problems 

assuring years of trouble-free service.

Most accidents can be avoided by using common 

sense.
IMPORTANT:  Ion Technologies is not responsible 

for losses, injury or death resulting from failure to 

observe these safety precautions, misuse, abuse 

or misapplication of pumps or equipment.

Marks & Meanings

CAUTION: 

Keep the pump equipment out of 

the reach of children! Warns that the failure to 

follow the directions given could cause serious risk to 

individuals or objects.

WARNING: 

This sign warns the operator that 

the failure to follow an instruction may damage 

the pump and/or the system.

Safety Warnings

CAUTION: 

Read  these  safety  warnings  first 

before  installing,  servicing,  or  operating  any 

pump.

Before Installation

This manual contains important information for the safe 

use of this product. Read this manual completely and 

follow the instructions carefully. Reasonable care and 

safe methods relating to the installation and operation 

of this product should be practiced. Check local codes 

and requirements before installation.

WARNING: 

Risk of Electrical Shock or 

Electrocution. May result in serious injury or 

death  or  fire  hazard.  Installer  must  disconnect  all 

electrical  sources  prior  to  installation,  handling  or 

servicing.  Only  qualified  personnel  may  install  this 

system. NFPA 70/National Electric Code (NEC) or 

local codes must be followed. System must be properly 

grounded according to NEC. Do not lift pump by power 

cord.

WARNING: 

Risk of Asphyxiation. Installer(s) 

and/or service personnel must use proper 

personal protective equipment and follow OSHA 29 

CFR 1910.146 or OSHA 29 CFR 1926. Pump may be 

installed in a location classified by as a confined space.

WARNING: 

Risk of Fire or Explosion. Do not 

smoke  or  use  open  flames  in  or  around  this 

system. This system is not intended for use in 

hazardous  locations  per  NFPA  70  National  Electric 

Code. Do not pump flammable liquids. Consult factory 

for  optional  equipment  rated  for  hazardous  location 

use.

Содержание ES45M-1

Страница 1: ...instruction may damage the pump and or the system Safety Warnings CAUTION Read these safety warnings first before installing servicing or operating any pump Before Installation This manual contains im...

Страница 2: ...termined that leaded copper alloys should not be used in potable water applications WARNING Installation wiring and junction connections must be in accordance with the National Electric Code and all a...

Страница 3: ...abrasions inspect frequently Never handle connected power cords with wet hands Never let cords or plugs lie in water outside the pit These pumps are offered in a three phase and single phase wiring co...

Страница 4: ...rd Type Cord O D Inches ES45M 1 1 2 115 1 P 11 0 16AWG 3C SJTW 34 ES45M 21 1 2 230 3 P 5 5 16AWG 3C SJTW 34 Specifications Description To pump domestic commercial and light industrial sewage Physical...

Страница 5: ...f provided operate properly Do not pump out of liquid WARNING A clearance under the pump for entrance of sewage solids must be a minimum of 2 inches to a maximum of 3 5 inches Submergence The pump sho...

Страница 6: ...pump See Figure 3 and the installation requires the switch be mounted to the pipe the pipe mount bracket is sold separately PN IN SPB1 1 Thermal Protection The normally closed N C over temperature se...

Страница 7: ...of 32 104 degrees F 3 Pump cord is not making contact in receptacle 4 Float is stuck It should operate freely in basin 5 If all of the above are OK then the motor could be malfunctioning Pump runs but...

Страница 8: ...6 1 091EP4006 SEAL PLATE 7 1 091EP4007 SHAFT SEAL 8 1 091EP4008 O RING 9 1 1 091EP4009 STRATOR ASSY 9 2 2 SCREW 9 3 1 CAPACITOR 9 4 1 GROUND LINE 9 5 1 MOTOR HOUSING 9 6 1 POWER CORD 9 7 1 NUT 9 8 1 W...

Страница 9: ...s ES45 Effluent Pump OPERATION MANUAL Dated 11 22 2017 Document Name ES45_OM indd Page 9 of 11 www ionproducts net Exploded View 1 2 3 4 5 6 7 8 9 1 9 2 9 3 10 11 12 13 9 2 9 4 15 16 9 5 18 17 9 9 9 8...

Страница 10: ...Ion Technologies ES45 Effluent Pump OPERATION MANUAL Dated 11 22 2017 Document Name ES45_OM indd Page 10 of 11 www ionproducts net Notes...

Страница 11: ...t in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unless and until B...

Отзывы: