Improving Performance with a Cache Storage Pool
A cache Storage Pool is a pool of solid-state drives designed to increase read and write performance on
your px12-350r Network Storage. You create a cache Storage Pool and then associate a
on a data
Storage Pool to the cache pool. You can create only one cache Storage Pool on your px12-350r.
To Add a Cache Storage Pool
You first create a cache Storage Pool to begin improving performance.
1. On the Drive Management page, click
Add Storage Pool.
2. In the Information section, enter a name for the cache Storage Pool.
3. To set the RAID protection, choose a value from the drop-down menu:
●
JBOD
Uses all of the storage space for data, providing contiguous storage space spanning all
member drives. Does not protect against data loss in the event of drive failure.
●
None (RAID 0)
Uses all of the storage space for data. Does not protect against data loss in the event of drive
failure.
●
Mirror Stripe (RAID 10)
Uses half of the storage space for protection, leaving half for actual data. Protects data in the
event of a single drive failure.
●
Parity (RAID 5)
Uses the space corresponding to one drive-size for protection, leaving remaining space for
storing actual data.
●
Double Parity (RAID 6)
Combines six or more drives in a way that protects data against loss of any two drives.
4. Select the checkbox of the solid-state drive or drives you want to add to the cache pool. You can
only designate SSDs as cache pool drives if they have not already been assigned to an existing
Storage Pool. All drives in a Storage Pool must be the same size.
Typically, you create a cache Storage Pool with one solid-state drive. However, if you create a
cache pool with at least two SSD drives and apply a redundant RAID protection, such as
mirroring, you can prevent against data losses in the event one of the SSDs fails.
5. Check Enable periodic consistency check to enable a monthly parity or mirror consistency
check.
6. Check Use for SSD Cache.
7. Click Create to add the new Storage Pool.
8. Click Cancel to discard any changes.
Assigning a Cache Pool to a Volume
After creating a cache Storage Pool, you assign a volume from a data Storage Pool to the cache pool. A
cache pool can be assigned to an existing or new volume.
Storage Pool Management
49
Improving Performance with a Cache Storage Pool
Содержание STORCENTER px12-350r
Страница 1: ...px12 350r Network Storage with LifeLine 4 0 User Guide ...
Страница 11: ...Setting up Your px12 350r Network Storage Setting up Your px12 350r Network Storage 1 CHAPTER 1 ...
Страница 32: ...Sharing Files Sharing Files 22 CHAPTER 2 ...
Страница 56: ...Storage Pool Management Storage Pool Management 46 CHAPTER 4 ...
Страница 68: ...Drive Management Drive Management 58 CHAPTER 5 ...
Страница 71: ...Backing up and Restoring Your Content Backing up and Restoring Your Content 61 CHAPTER 6 ...
Страница 113: ...Sharing Content Using Social Media Sharing Content Using Social Media 103 CHAPTER 10 ...
Страница 119: ...Media Management Media Management 109 CHAPTER 11 ...
Страница 131: ... Delete a torrent job Click to delete the torrent download Media Management Torrents 121 ...
Страница 140: ...Upgrading Your px12 350r Network Storage Upgrading Your px12 350r Network Storage 130 CHAPTER 13 ...
Страница 145: ...Hardware Management Hardware Management 135 CHAPTER 15 ...
Страница 156: ...Additional Support AdditionalSupport 146 ...
Страница 159: ...Legal Legal 149 ...