background image

 
 
            

 

 

 

 

Technology Expert in Hypertension Management

 

© 

I.

E.

M

G

mb

H

 | 

R

e

v.

 1

.0

 –

 2

3

.0

6

.2

0

1

6

 | 

w

w

w

.i

e

m.

d

e

 

 

– Plugging in the cuff 

– Putting on the cuff 

 

 

Plug the air tube socket into the air tube connection 
of the device.  

-

  Put on the cuff and fasten it with the Velcro. 

-

  The tube must run centrally along the inside of the 

forearm, in the direction of the middle finger. 

-

  The lower edge of the cuff must lie about 2 cm 

above the crook of your arm. 

-

  The artery marker must lie centrally on the inside 

of your arm and point downwards. 

 

 

– Correct sitting position 

– Carrying out a reading 

 

-

 

Sit comfortably on a chair and place your elbows 
on the table. 

-

 

The arm cuff should be the same height as your 
heart. 

-

 

Relax your arm and turn the palm of your hand 
upwards. 

-

 

Place your feet flat on the floor and place your 
legs next to each other. 

-

  Press the 

START

 button to start a reading. The 

start of a reading is confirmed by a signal tone. 

-

  During your first reading, the cuff pumps up 

gradually in order to determine the pressure 
necessary for calculating your systolic blood 
pressure. 

-

  During every further reading, it is immediately 

pumped up to the systolic blood pressure value 
that has already been determined. 

-

  After pumping up, the pressure is gradually 

released. 

-

  A reading can be cancelled at any time by pushing 

the 

START

 button again. The air is automatically 

released! 

 

 

– Transferring the data 

10 

– Information 

-

  After your blood pressure values have been 

measured, these appear on the display. 

-

  Take off the arm cuff. The blood pressure reading 

has ended. 

-

  Following this, the blood pressure measuring 

device establishes a connection to the mobile 
phone network (

Y

). 

-

  As soon as the mobile connection is established  

(the symbol -

G

- appears on the display), the 

readings are transferred (



). 

-

  A signal tone confirms the measurement values 

have been successfully transferred. 

-

  If the blood pressure values are not successfully 

transferred, an error message appears on the 
display. Note down the error code. 

-

  The blood pressure values remain saved in the 

measuring device and are transferred after the 
next blood pressure reading. 
 

-

  When changing the batteries take care to insert 

the batteries with the correct polarity and when 
inserting them, do not press or hold down the 

START

 button. 

 