SAFETY INFORMATION 

To ensure a safe and smooth operation of your InWin IW-RS104-07, it is essential that you choose 
an appropriate location for the system, provide an appropriate operating environment and supply 
an adequate amount of power for all components of the system. As you plan for installation, follow 
the guidelines below to ensure that the system and its environment are safely and appropriately 
positioned for efficient operation and service. Your system should be installed and serviced only by 
a qualified technician. 
 

Environment Selection:

 The system is designed to operate in a typical office environment:   

 

The location should be clean, dry and free of airborne particles.   

 

It should be placed in a well-ventilated room, and away from sources of heat including direct 
sunlight and radiators.   

 

It should be kept away from sources of vibration or physical shock.   

 

The space should be accommodated with a properly grounded wall outlet, and with sufficient 
space to access the power supply cords.   

 

The operating environment temperature should be around 0°C to 40°C (32°F to 104°F). 

 

Heed  Safety  Instructions:

  Before  working  with  InWin  IPC/storage  server  products,  we  strongly 

recommend you use this guide as a reference and follow the safety instructions. The instructions in 
this manual will help you ensure and maintain compliance with existing product certifications and 
approvals. Follow the described, regulated components mentioned in this manual. Use of non-UL 
listing  products  or  other  regulators  may  not  comply  with  product  regulations  in  the  region(s)  in 
which the product is sold.   
 

System Power On/Off:

 The power button DOES NOT totally turn off the system AC power. To remove 

the power of the system, you must unplug the AC power cord from the outlet or the system’s power 
supply units. Make sure the power cord is unplugged before you open the chassis, add or remove 
any components.   
 

Hazardous Conditions, Devices and Cables:

 Hazardous electrical conditions can be present on/in 

power supply units and their cables. Disconnect the power cord and any other devices attached to 
the  server  before  opening  the  case.  Failing  to  follow  safety  procedures  will  increase  the  risk  of 
personal injury or equipment damage.   

Содержание IW-RS104-07

Страница 1: ...IW IW IW IW RS104 RS104 RS104 RS104 07 07 07 07 User Manual User Manual User Manual User Manual ...

Страница 2: ...d Expansion Card Installation 11 2 2 HDD Tray Installation 11 2 3 Backplane Connection 11 2 4 Fan Installation 11 2 5 Power Supply Installation 11 2 5 1 Power Supply Cable Information 12 2 6 Internal HDD Installation 14 2 7 Connecting Cables 14 2 7 1 Connecting Backplane Through SAS Connectors 14 2 7 2 Connecting LED Cable Front Control Panel and Front USB I O Ports 14 2 8 Installing the Slide Rai...

Страница 3: ...3 Backplane Introduction 18 4 Compatibility Lists 19 5 Q A 20 6 Technical Support 21 ...

Страница 4: ... from sources of heat including direct sunlight and radiators It should be kept away from sources of vibration or physical shock The space should be accommodated with a properly grounded wall outlet and with sufficient space to access the power supply cords The operating environment temperature should be around 0 C to 40 C 32 F to 104 F Heed Safety Instructions Before working with InWin IPC storag...

Страница 5: ...er carefully and plug the jumper to cover the jumper pins on the backplane Once you need to remove the jumper grip the jumper and carefully pull without squeezing CAUTION To avoid damage and maintain your safety please read the following terms listed below 1 Do not populate hard drives and turn on the power until the system has stabilized Make sure hard drives and other components are properly con...

Страница 6: ...D NVMe SAS SATA SFF 8639 x 4 Backplane 3 Host Mini SAS HD SFF 8643 x 1 HDD SAS SATA x 4 Cooling Fan 40 x 56mm PWM easy swap fans x 6 21500RPM modular design with anti vibration Expansion Slot Full height PCIe slot x 1 via riser card Material Material SGCC Thickness 1 0mm Rail Kit Supports 28 tool less ball bearing slide rails Product Dimensions D x W x H Chassis Only 676 5 x 438 x 43 4mm 26 6 x 17...

Страница 7: ...4 Product Dimensions ...

Страница 8: ...4 HDD Interface NVMe SAS SATA SFF 8639 x 4 Backplane 2 Oculink Backplane Dimensions W x H 416 6mm x 33mm Backplane Type Passive Host Interface Mini SAS HD SFF 8643 x 1 Oculink SFF 8611 x 4 HDD Interface NVMe SAS SATA SFF 8639 x 4 Backplane 3 SAS SATA Backplane Dimensions W x H 416 6mm x 33mm Backplane Type Passive Host Interface Mini SAS HD SFF 8643 x 1 HDD Interface SAS SATA x 4 ...

Страница 9: ...6 1 Product Introduction 1 1 Box Contents When you open the IW RS104 07 box the contents should include following ...

Страница 10: ...to 2 pin Adapter x 1 9 2 5 SSD screws x 24 4 Cable Ties and Mounts x 5 10 Backplane Jumper x 1 5 Motherboard Screws x 11 11 Single Power Supply Accessories a Countersunk Flat Head Screws x 2 b Oval Head Screws x 4 c Mounting Bracket x 1 6 Motherboard Stand off Sockets x 11 12 Redundant Power Supply Accessories a Screws x 6 b Mounting Brackets x 2 ...

Страница 11: ...8 1 3 General Information When you open the chassis it should reflect the diagram s image ...

Страница 12: ...2 Power ON OFF Button with LED Blue Solid on System is powered on Off System is off 3 NMI Button No LED function Press the button to activate user defined function 4 System Reset Button No LED function Press the button to activate system reset 5 USB3 0 Connector No LED function USB devices connections 6 LAN LED LAN1 LAN4 Amber Blinking Link between system and network Off No data transmission or re...

Страница 13: ...rence InWin compatibility list to select the compatible models 2 System I O Depends on M B Specifications InWin offers a customized service for 1U I O shield For more information please contact InWin s sales reps 3 Full Height PCIe Slot x 1 The slot supports standard high profile cards The bracket should be removed before using ...

Страница 14: ...tion video please visit 07 Series HDD Tray Installation 2 3 Backplane Connection The IW RS104 07 supports three high end backplanes including Slimline Oculink and Mini SAS HD For a quick installation video please visit 07 Series SAS SATA Backplane Connection and 07 Series Oculink and Slimline Backplane Connection 2 4 Fan Installation The IW RS104 07 s built in fan modules feature a tool less desig...

Страница 15: ...12 2 5 1 Power Supply Cable Information 650W Single PSU Cable Information Length Unit mm ...

Страница 16: ...13 750W Redundant PSU Cable Information Length Unit mm ...

Страница 17: ... SATA 6Gps and SATA 3Gps HDD SSD Some of the backplanes support NVMe SSDs through either Oculink x 4 or Slimline x 4 connectors 2 7 1 Connecting Backplane Through SAS Connectors The InWin IW RS104 07 needs the SAS cable to connect to the backplane and your motherboard or RAID controller InWin provides verified SAS cables for installation please contact InWin sales reps to get more information 2 7 ...

Страница 18: ...nstructions to mount the rail onto your cabinet or chassis rack 2 8 2 Installing the Slide Rail Step 1 Release the inner rail from the slide No Connector Name Color Front I O Indication P2 NMI Switch Black Brown NMI Button P3 Reset Switch Red Orange Power Reset Button with LED P4 LAN LED 4 Yellow Green LAN LED P5 LAN LED 3 Blue Purple LAN LED P6 LAN LED 2 Gray White LAN LED P7 LAN LED 1 Black Brow...

Страница 19: ...the arrows show Step 3 Install the outer rails and the brackets onto the rack 2 8 3 Mounting the chassis onto the cabinet Step 1 Make sure the ball bearing retainer is at the forefront Step 2 Insert the inner rail to the outer rail which has already locked up on the cabinet ...

Страница 20: ...17 Step 3 Mount the inner rail onto the chassis by the direction which the arrows show on the image Step 4 Tighten the thumb screws to secure the chassis ...

Страница 21: ...der Please reference the backplane user guide to complete the installation The download link is at the download section of each product Please visit the InWin website ipc in win com SAS3 Backplane Top Side Bottom Side Oculink Backplane Top Side Bottom Side ...

Страница 22: ...ut 3 GND FAN1 FAN12 Connect to fan modules The backplane supports up to 12 fan modules 4 Compatibility Lists To reach the best performance and avoid system failure InWin strongly recommends customers to choose the components from InWin s compatibility list All the components are tested in InWin s lab and assured the components are compatible with InWin s chassis You can download the latest updated...

Страница 23: ...he best performance we recommend following the motherboard or RAID controller vendors instructions d Does the chassis support SSDs or flash NVMe drives A SAS SATA and NVMe SSD connections can be attached to the InWin IW RS104 07 We recommend customers refer to InWin s compatibility list to confirm if the SSDs are listed or please contact InWin s sales reps for better reference e If I don t need th...

Страница 24: ...t a solid hardware RAID system it is required However whether you should use the RAID controller card or not depends on your purpose and budget We recommend discussing with InWin s channel partners for their suggestions i Where can I buy the SAS cable A The 12Gb SAS to 4 SATA or 12Gb SAS to 6Gb SAS are standard cables that you can easily buy from many vendors You can buy the verified cable from In...

Отзывы: