iMars grid-tied solar inverters
Technical parameters
63
10 Technical parameters
Table 10-1Technical parameters
Model
Three-phase
BG6KTR
BG8KTR
BG10KTR
Input(DC)
Max. DC voltage (V)
1000
1000
1000
Starting voltage (V)
200
200
200
MPPT voltage(V)
180~800
180~800
180~800
Operation voltage (V)
300 - 800
300 - 800
320 - 800
MPPT/strings per MPPT
2/1
Max. DC power (W)
6300
8400
10400
Max. input current (A)
11x2
14x2
19x2
Isc PV(A)
12.5 x2
15.5 x2
21 x2
Max inverter backfeed current to the
array(A)
0
0
0
DC switch
Optional
Output(AC)
Max output power
6000
8000
10000
Voltage(V)/ frequency(Hz)
320~460Vac, 50Hz(47~51.5Hz)/ 60Hz(57~61.5Hz)
Max. AC current (A)
9.6
12.8
16.1
Maximum output fault current
265A @ 34ms
AC inrush current
Less than 10 A
Maximum output overcurrent
protection(A)
19
25.3
31.8
Power factor
-0.80~+0.80(adjustable)
Harmonic distortion
< 3% (rated power
˅
System
Cooling
Natural cooling
Air cooling
Maximum efficiency
97.50%
97.60%
98.20%
European efficiency
97.00%
97.00%
97.60%
MPPT efficiency
99.9%
Protection degree
IP65
Power consumption
< 1W
Isolation mode
Transformerless
Protective class
I
Overvoltage category
AC:III,PV:II
inverter topology
Non-isolated
Pollution degree
3
Operation temperature
(-25
ć
~+60
ć
)
ˈ
derate after 45
ć
Relative humidity
4~100%, Condensation
Max. altitude(m)
<2000 (derate if the altitude
˚
2000)
Displaying
LED/LCD, backlit display
Systerm language
English, Chinese, German, Dutch
Communication
RS485 (standard); handheld keypad; WiFi (optional)
DC terminal
BC03A / BC03B
Noise dB(A)
≤
30
<50
Installation mode
Wall installation
Others
Grid standard
DIN VDE 0126-1-1
˖
2013
ˈ
VDE-AR-N 4105
˖
2011
ˈ
DIN VDE V 0124-100
˖
2012
ˈ
IEC 61727
˄
IEC62116
˅ˈ
AS/NZS 4777.2
˖
2015
ˈ
NB/T32004-2013
ˈ
IEC 60068-2-1
˖
2007
ˈ
IEC 60068-2-2
˖
2007
ˈ
IEC 60068-2-14
˖
2009
ˈ
IEC 60068-2-30
˖
2005
ˈ
IEC 61683
˖
1999
ˈ
C10/11
˖
2012
Safe certificate / EMC category
IEC 62109-1
˖
2010
ˈ
IEC 62109-2
˖
2011
ˈ
EN 61000-6-2: 2005 / EN 61000-6-3:2007/A1:2011
Protection
Input overvoltage protection, input overcurrent protection, DC isolation monitoring, DC monitoring, grounding fault current monitoring, grid
monitoring, island protection, short circuit protection, overheating protection
Содержание iMars BG10KTR
Страница 1: ...Operation Manual iMars SJE UJFE 4PMBS OWFSUFS INVT Solar Technology Shenzhen Co Ltd...
Страница 2: ......
Страница 14: ...iMars grid tied solar inverters Product overview 12 Figure 2 2Type of grid...
Страница 44: ...iMars grid tied solar inverters Display panel 42 LCD menus...
Страница 66: ......
Страница 67: ......
Страница 68: ...201807 V1 1...