Goodrive350-19 series VFD for crane
Function parameter list
-223-
Function
code
Name
Description
Default
Modify
5: Modbus communication
6: PROFIBUS/CANopen/DeviceNet
communication
7: Ethernet communication
8: Pulse frequency HDIB (100% corresponding
to triple the motor rated current)
9: EtherCAT/Profinet communication
10: Programmable expansion card
11: 216 communication
P03.19
Setting source of
braking torque
upper limit
0: Keypad (
1
–11: Same as those for P03.18
0
○
P03.20
Electromotive
torque upper limit
set through
keypad
0.0
–300.0% (of the motor rated current)
Note: It can be modified only when P11.26=1
indicating special functions are enabled.
250.0%
○
P03.21
Braking torque
upper limit set
through keypad
250.0%
○
P03.22
Weakening
coefficient in
constant power
zone
Used when the AM is in flux-weakening control.
T
f
0.1
Flux-weakening
coefficient of motor
1.0
2.0
Min. flux-weakening limit of motor
and
are valid
at constant power. The motor enters the
flux-weakening state when the motor runs above
the rated speed. Change the flux-weakening
curvature by modifying the flux-weakening
control coefficient. The larger the coefficient, the
steeper the curve, the smaller the coefficient, the
0.3
○
P03.23
Lowest
weakening point
in constant power
zone
20%
○