The function codes are used to set the reactive current closed-loop function when the synchronous motor is at VF mode.
Function
code
Name
Description
Setting range
Default
P04.36
Reactive current
closed-loop integral
switch-over
frequency
0
–400.00Hz
0
–400.00
50.00Hz
P04.37
Reactive current
closed-loop
high-frequency
integral
0
–5000
0
–5000
30
P04.38
Reactive
closed-loop voltage
limit in PM-VF
control
0
–16000V
0
–16000
8000
P04.39
IF enabling
selection
0: Invalid
1: Valid
0
–1
0
P04.40
IF control current
0.0
–200.0%
0.0
–200.0
50.0%
P04.41
IF control
proportional gain
0
–5000
0
–5000
350
P04.42
IF control integral
gain
0
–5000
0
–5000
10
P04.43
IF switching off
frequency
0.00
–20.00Hz
0.00
–20.00
10.00Hz
P05 group
––Input terminals
Function
code
Name
Description
Setting range
Default
P05.00
HDI input type
0: HDI is high-speed pulse input
1: HDI is digital input
0
–1
0
The function code is used to set the S8 input type.
Function
code
Name
Description
Setting range
Default
P05.01
Function of S1
terminal
0: No function
1: Run forward
2: Run reversely
3: Three-wire running control
4: Jog forward
5: Jog reversely
6: Coast to stop
7: Reset faults
8: Pause running
9: External fault input
10: Increase frequency setting (UP)
11: Decrease frequency setting
(DOWN)
12: Clear the frequency
increase/decrease setting
13: Switch between A setting and B
0
–63
1
P05.02
Function of S2
terminal
0
–63
4
P05.03
Function of S3
terminal
0
–63
7
P05.04
Function of S4
terminal
0
–63
0
P05.05
Function of S5
terminal
0
–63
0
P05.06
Function of S6
terminal
0
–63
0
P05.07
Function of S7
terminal
0
–63
0
P05.08
Function of S8
terminal
0
–63
0