GD310-UL series VFD
Basic operation instruction
-166-
Function
code
Name
Description
Default
value
P00.03
Max output frequency P00.03
–400.00Hz
60.00Hz
P00.06
A frequency command
0: Keypad
1: AI1
2: AI2
3: AI3
4: High-speed pulse HDI setting
5: Simple PLC program setting
6: Multi-step speed running setting
7: PID control setting
8: MODBUS communication setting
9: PROFIBUS/CANopen communication setting
10: Ethernet communication setting (reserved)
11: Reserved
0
P00.11
ACC time 1
0.0
–3600.0s
Depend
on model
P00.12
DEC time 1
0.0
–3600.0s
P05.01
–
P05.09
Digital input function
selection
26: Traverse Pause (stop at present frequency)
27: Traverse reset (return to center frequency)
P08.15
Traverse range
0.0
–100.0% (relative to the set frequency)
0.0%
P08.16
Sudden jumping
frequency range
0.0
–50.0% (relative to the traverse range)
0.0%
P08.17
Traverse boost time
0.1
–3600.0s
5.0s
P08.18 Traverse declining time 0.1
–3600.0s
5.0s
7.17 Pulse counter
Goodrive310-UL series VFDs support pulse counter which can input counting pulse through HDI
terminal. When the actual length is longer than or equal to the set length, the digital output terminal
can output length arrival pulse signal and the corresponding length will clear automatically.