![involight LEDBAR508R Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/involight/ledbar508r/ledbar508r_user-manual_2085488006.webp)
6
CH19
LED4
0-255
0-100%
CH20
LED5
0-255
0-100%
CH21
LED6
0-255
0-100%
CH22
LED7
0-255
0-100%
Note:Set master-slave,master machine at auto or sound mode and slave
machine at d001.
Maintenance
Maintenance should be performed every 15-day period, by using a sponge
which is dipped with alcohol, rather than wet cloth or other chemical liquid, to
clean the mirror.
Always disconnect from the mains when the device is not in use or before
cleaning it.
Warning
Power must be disconnected before maintenance or repair. Do not look at the
light source directly
Note
Don't separate laser machine from laser power and repair them by yourself,
otherwise no good repair service will be supplied.
Technical Specifications
1.Power Supply: AC 100-240V 50/60Hz
2.Rated Power: 60W
3.Fuse: BDGP 5*20mm,2A
4. Single Red: Red 500mW/638nm*8 (200mW/650nm*8 option) + 7*3W
Amber LEDs
5. Working Mode: Sound Active/ Auto-play/DMX512/Master-Slave
6. Output laser spot diameter: 14mm
7.Control Signal: DMX512 signal
8.DMX Control Channels: 7/22
9.Operating Temperature: -1º--35º
10.Storage Temperature: -10º--60º
11.Warm-Up Time :<15 min
12.Laser Classification: 3B
13.Modulation: TTL