background image

10

InvisibleFence.com

Multi-Area Avoidance:

Your Shields® Gate Transmitter and the Computer Collar® Unit are 
preset to operate on 

Channel A (Code A)

. For homes with two or more 

pets, this setting is usually sufficient as long as all pets are required 
to avoid the same protected areas like keeping all pets away from 
the dining room, off the sofa, etc. In some multi-pet homes, it may be 
desired to allow one pet access to an area while denying the same 
access to another pet.

 

•    

When set to Channel A (Code A)

, Shields Gate denies access 

to pets wearing a Computer Collar programmed to Channel A. 
(Channel A is the default setting for the Computer Collar® Unit.)

 

•  

When set to Channel B (Code B)

, Shields Gate denies access to 

pets wearing a Computer Collar programmed to Channel B.

 

•  

When set to Channel A-B (Code A + B)

, Shields Gate denies 

access to all pets wearing a Computer Collar® set to Channel A or B.  

Note: Your local Invisible Fence® Brand dealer can set Computer 
Collars to not activate to any Shields® units.

Programming the Computer Collar:

This function is only used with devices set to Shields mode.

 

•  Prior to programming ensure all Computer Collar® units are 

removed from pets and are at least 3 feet from the Shields  
Gate or any Shields transmitter.

 

•  Follow procedure on page 7, changing the Channel Setting on 

Shields Gate to select 

Channel A

 or 

Channel B

 for programing 

into the Computer Collar. Once complete turn the unit back 
over and set it down on a flat surface. 

Note: Shields Gate will 

not enter into programming mode if this switch is set to A+B.

 

 

•  Press and hold the 

PROGRAM

 

(P)

 button while lowering the 

Computer Collar from directly above Shields Gate.

 

•  Stop lowering when the Computer Collar® Unit begins to flicker 

yellow and release the 

PROGRAM

 button on the transmitter 

when the Computer Collar begins to flash green.  

 

•  The Computer Collar is now programmed to the desired channel.

 

•  Verify operation by turning 

ON

 Shields Gate and moving the Computer Collar into the signal 

field. You will hear the Computer Collar beep when it activates. 

Note: Make sure any Computer Collar® units you do not wish to program are more than 3 feet from  
Shields Gate or have the Power Cap® Battery removed. Do not perform this procedure while the 
Computer Collar is on a pet. 

Содержание Shields Gate

Страница 1: ...Invisible Fence Indoor Solutions Shields Gate Owner s Manual InvisibleFence com...

Страница 2: ...sult in death or serious injury CAUTION used with the safety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address safe u...

Страница 3: ...t avoidance containment system All Invisible Fence systems are designed for domesticated animal use only Never attempt to use this product for any purpose not specifically described in this manual The...

Страница 4: ...ange 8 Changing the Channel Setting 8 Boundary Plus System Operation 9 Adjust Signal Field Range 9 Verify Signal Field Range 9 Multi Area Avoidance 10 Programming the Computer Collar Unit 10 Linking M...

Страница 5: ...rechargeable battery pack You may use the included AC adapter for locations near an electrical outlet The AC adapter is also used for charging the transmitter The Transmitter has four control buttons...

Страница 6: ...l illuminate red while charging o The power button will illuminate green when charging is complete Battery life of approximately 30 days can be expected from a fully charged battery The Shields Gate t...

Страница 7: ...nergy Rate 3 is the fastest and consumes the most energy The faster the data rate the more consistent the boundary o A B B A CODE Data types used to separate pet when unit is set to Shields mode This...

Страница 8: ...omputer Collar will beep as it approaches the outer range of the signal field width set in Step 2 The beeping will be accompanied by a correction o If the Computer Collar fails to beep see the trouble...

Страница 9: ...k o With the unit ON press the RANGE UP or the RANGE DOWN buttons to increase or decrease the signal field range The first indicator equals 10 inches of signal field Each additional number represents...

Страница 10: ...ar This function is only used with devices set to Shields mode Prior to programming ensure all Computer Collar units are removed from pets and are at least 3 feet from the Shields Gate or any Shields...

Страница 11: ...for Different Pets technology please go to the section on multi pet households Once the signal field is established 1 Use the Invisible Fence training flags to mark the desired area Flags should be s...

Страница 12: ...If your pet lingers in the signal field or ignores the signal field please contact your Invisible Fence Dealer Your pet s indoor correction level may need an adjustment If your pet is new to Invisible...

Страница 13: ...transmitter when the LCD is black will not damage the device Range is too low or too high Check for low battery audible chirp once every 30 seconds and flashing LCD If low battery is indicated plug th...

Страница 14: ...geable Lithium Ion Polymer Li ion battery pack with a 3 7 Volt 420 mAh capacity Perchlorate Battery Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate Impor...

Страница 15: ...accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a specific installation If interference does...

Страница 16: ...___________________________ Dealer Phone_________________________________ System Frequency____________________________ Notes ___________________________________________ _______________________________...

Отзывы: