www.invisiblefence.com
7
At Start-Up
Color
Indicator
Status
GREEN
5 flashes
Battery strength is good
RED
4 flashes
Battery strength is weakening; replace Power Cap
®
at first opportunity
NO LIGHT
Battery is dead; replace Power Cap
®
immediately
Due to the initial power draw on the battery, a fresh Power Cap
®
is required when powering up the new Boundary Plus
®
Computer Collar
®
either out of the box or when a Boundary Plus
®
Computer Collar
®
has not been powered up for over one
minute. Use of an old Power Cap
®
may result in the Boundary Plus
®
Computer Collar
®
blinking red during the first Power
Cap
®
test sequence. If this occurs; wait five to ten seconds after the last red blink, then unlock and relock the Power Cap
®
. The
LED should now flash green. If this does not occur, replace with a new Power Cap
®
.
Should the red LED flash continuously while your pet is wearing the Boundary Plus
®
Computer Collar
®
, the Power Cap
®
strength is dangerously low; replace Power Cap
®
immediately.
Replace your existing Power Cap
®
with one supplied via your Power Cap
®
plan, available through your Invisible Fence
®
Brand Dealer. If a fresh Power Cap
®
is not available, contact your Invisible Fence
®
Brand Dealer for a replacement. Once a
replacement Power Cap
®
is installed and the signal field checked (see page 8 for instructions on checking the signal field),
put the Boundary Plus
®
Computer Collar
®
on your pet. The Invisible Fence
®
Brand pet containment system is now ready.
LO
CK
UN
LOC
K
LOCK
UNL
OCK
Alignment Lug
(one on each side)
Changing the Power Cap
®
1. Use a small, thin coin to remove the Power Cap
®
from the Boundary Plus
®
Computer
Collar
®
. Insert the coin in the slot on top of the Power Cap
®
and turn it counter-
clockwise. Do not push down while turning. The Power Cap
®
unit will rotate up and
out of the Boundary Plus
®
Computer Collar
®
unit’s battery chamber.
2. Install a new Power Cap
®
using the following steps:
a. Line up the lugs on the bottom of the Power Cap
®
with the grooves in the sides of
the Boundary Plus
®
Computer Collar’s
®
battery chamber. Make sure the metal tabs
on the bottom of the Power Cap
®
are not bent.
b. Place the Power Cap
®
into the chamber while gently, but firmly, turning it clockwise
with your fingers.
c. Use a small, thin coin in the slot on top of the Power Cap
®
to turn it clockwise until
the slot on the top of the Power Cap
®
is lined up with the two small raised tabs on
the bottom of the receiver. Do not over-tighten by turning the slot past the tabs on
the Computer Collar
®.
WARNING
The use of any power source other than an Invisible Fence
®
Brand Power Cap
®
may cause a receiver to operate erratically or fail. The use of unnecessary force may damage the
case and render the Power Cap
®
inoperable. NEVER open a Power Cap
®
, dispose of it in fire,
recharge it, expose it to heat above 212°F (100°C), or expose its contents to water. Doing so can
cause leakage or explosion and may lead to personal injury.
BATTERY AND TESTER MUST
BE AT ROOM TEMPERATURE
TEST FOR 5 SECONDS
Replace battery when green light
is out and red light is dim or out.
Invisible Fence, Inc.
Green
Red
Power Cap
®
Tester
Power Cap
®
Tester
We strongly recommend that each customer obtain a Power Cap
®
tester, which is available
through your Invisible Fence
®
Brand dealer. At least once a month, check the Computer
Collar
®
battery with the Power Cap
®
tester. The Power Cap
®
tester measures the internal
resistance of a Power Cap
®
and shows how much life is left in the battery.
To test a Power Cap
®
with the Power Cap
®
tester, remove the Power Cap
®
from the Computer
Collar
®
and put it into the Power Cap
®
tester the same way that you would put it into a
Computer Collar
®
. If the battery is good, the green and red LEDs on the tester will both light.
If neither LED on the tester lights, or just the red LED lights dimly, the Power Cap
®
needs to
be replaced.