Invicta SEDAN S Скачать руководство пользователя страница 15

 

SEDAN S stove

 

 

 Reference: 9450/ver1.1 

 

XD le 16/05/2018 

   

 

 

 

 

 

 

 

 

 

        Page 15 of 16 

 
 
 

“The Clean Air Act 1993 and Smoke Control Areas” 

 
Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control 
area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed boiler if located in a 
designated smoke control area. It is also an offence to acquire an "unauthorised fuel" for use within a smoke control area 
unless it is used in an "exempt" appliance ("exempted" from the controls which generally apply in the smoke control area). 
 
In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to 
sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015. Similarly in Scotland appliances are 
exempted by publication on a list by Scottish Ministers under section 50 of the Regulatory Reform (Scotland) Act 2014. In 
Northern Ireland appliances are exempted by publication on a list by the Department of Agriculture, Environment and Rural 
Affairs under Section 16 of the Environmental Better regulation Act (Northern Ireland) 2016. 
In Wales appliances are exempted by regulations made by Welsh Ministers. 

Further information on the requirements of the Clean Air Act can be found here

https://www.gov.uk/smoke-control-area-rules

 

Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke 
control areas and you can contact them 

for details of Clean Air Act requirements” 

 
The Sedan S+ stove has been recommended as suitable for use in smoke control areas when burning wood logs and when 
fitted with a modified air control to prevent closure of the secondary air beyond 15mm open. 
 

Refuelling on to a low fire bed  
 
If there is insufficient burning material in the firebed to light a new fuel charge, excessive smoke emission can occur. 
Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a 
reasonable period. If there are too few embers in the fire bed, add suitable kindling to prevent excessive smoke 
 
 
Fuel overloading 
 
The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause excess smoke.

 

 

Operation with door left open  
Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance door left 
open except as directed in the instructions.  
 
Dampers left open  
Operation with the air controls or appliance dampers open can cause excess smoke. The appliance must not be operated 
with air controls, appliance dampers or door left open excepas directed in the instructions.

 

Содержание SEDAN S

Страница 1: ...Po le SEDAN S R f rence 94504 XD le 16 05 2018 Page 1 sur 16 Po le bois SEDAN S R f rence 94504 3 maill noir 6 maill ivoire 7 maill rouge 8 maill gris...

Страница 2: ...er l appareil sur une dalle en b ton de largeur 100 cm longueur 100 cm paisseur 45mm recouverte d une face r fl chissante c t appareil plaque m tallique type inox ou face c ramis e brillante l apparei...

Страница 3: ...sur le sch ma ci dessous Si les parois avoisinantes sont en mat riaux incombustible et ne se d gradent pas sous l action de la chaleur la temp rature du mur pouvant atteindre 200 C ces dimensions peuv...

Страница 4: ...Po le SEDAN S R f rence 94504 XD le 16 05 2018 Page 4 sur 16 39 39 7 13 23 8 13 5 22 3 2 10 18 16 15 14 36 37 31 13 11 41 12 9 32 20 5 33 6 1 17 35 19 4 21 26 24 28 27 29 34 25 3 20 23 13 30 38 40...

Страница 5: ...re AI303008 19 2 Vis t te frais e de 6x25 AV8636250 20 5 Ecrou embase de 6 AV7220060 21 1 Buse 150 ext 5 pouces int F612338B 22 2 Joint de buse 5 longueur 0 437 m tre AI303005 23 4 Vis t te hexagonale...

Страница 6: ...ossible de laisser la porte entre ouverte pour faciliter cette phase d allumage mais en maintenant toujours l appareil sous surveillance Fonctionnement Puissance nominale et combustion prolong e Le fo...

Страница 7: ...on prolong e registre ferm Registre d allumage L action sur le registre de r glage d allure au del de la position Puissance nominale permet d obtenir un suppl ment d air pour l allumage Cette position...

Страница 8: ...SEDAN S stove Reference 9450 ver1 1 XD le 16 05 2018 Page 8 of 16 SEDAN S Wood stove Reference 6450 DEFRA...

Страница 9: ...of or containing combustible or heat susceptible materials Where possible sit the appliance at the centre of a concrete plinth size 100cm x 100cm x 45mm thick covered by a metal plate with an upward...

Страница 10: ...to If the surrounding walls are made from incombustible materials and are not susceptible to degradation under heat wall temperatures up to 200 C this clearance can be reduced to 150mm 550 mm Back wal...

Страница 11: ...EDAN S stove Reference 9450 ver1 1 XD le 16 05 2018 Page 11 of 16 39 39 7 13 23 8 13 5 22 3 2 10 18 16 15 14 36 37 31 13 11 41 12 9 32 20 5 33 6 1 17 35 19 4 21 26 24 28 27 29 34 25 3 20 23 13 30 38 4...

Страница 12: ...34B 18 1 Fireplate sealing strip 8mm dia x 0 976m AI303008 19 2 Countersunk screw 6x25 AV8636250 20 5 M6 flange nut AV7220060 21 1 Outlet ring 150mm O D x 5 I D F612338B 22 2 Outlet ring sealing strip...

Страница 13: ...and reducing the air intake paying attention to the following Do not throttle the air back so much that it puts the fire out If this looks to be happening open up the air intake for a while longer Do...

Страница 14: ...help light the initial fire This position is reserved for lighting and rekindling and must not be maintained for more than 5 minutes after which there is a serious risk of damage to the appliance and...

Страница 15: ...information on the requirements of the Clean Air Act can be found here https www gov uk smoke control area rules Your local authority is responsible for implementing the Clean Air Act 1993 including...

Страница 16: ...llation doit avoir Une alimentation en air frais d di la combustion Une vacuation des produits de combustion L appareil et l installation doivent tre entretenus r guli rement Toutes les surfaces de l...