background image

Page  38 

 

 

FAULT FINDING 

– VIBRATORS 

 

1. 

Vibrator does not start or fails to run. 

 

Provided that supply voltage is present at the vibrator terminal box check the following: 
 
a)  Supply voltage is correct and starter is operating correctly. 
b)  All three phases of supply voltage are connected and the brass links in the vibrator terminal box 
 

are present and in correct position for supply voltage. 

c) 

Vibrator is clear of “earth” faults and the stator winding is not open circuit in any one phase and 

 

no short circuits exist between adjacent turns. 

d)  Vibrator is not overloaded electrically or mechanically (See 2). 
 
 

2. 

Vibratory current exceeds rated full load current or overheats 

 

Check: 
 
a)  That  vibrator  fixing  bolts  are  correctly  tightened  and  there  is  no  damage  to  end  covers 
 

preventing weights rotating. 

b)  Bearings are not partially seized or over greased. 
c)  Out of balance weights are not set at too great force output, particularly on hopper applications. 

 
 

3. 

Vibrator Noisy 

 

NOTE

  Due  to  the  increased  radial  clearance  in  the  bearings  it  is  normal  for  vibrators  to  emit  a 

 certain amount of noise and they should not be compared with standard electric motors. 
 

 

Check: 

 

a)  That there are no loose parts on the vibrator. 
b)  End covers are not damaged and fouling out of balance weights. 
c)  Noise is not due to bearing failure. 

 
 

4. 

Vibrator(s) does(do) not attain synchronous speed 

 

Check: 
 
a)  That the vibrator is not wrongly connected (star instead of delta) 
b)  Supply voltage and supply frequency are not too low. 
c)  Vibrator is not overloaded or partially seized. 

 

 

 

 

Содержание BLz Series

Страница 1: ...equest INVICTA VIBRATORS A Division of Grantham Engineering Limited Harlaxton Road Grantham Lincolnshire ENGLAND NG31 7SF Telephone 44 0 1476 566301 Fax 44 0 1476 590145 E mail sales invictavibrators...

Страница 2: ...a vibrator mounted in any orientation is fed from a variable speed drive it shall be connected to a suitable controlling and regulating device as defined in article 1 b of European Directive 2014 34 E...

Страница 3: ...re designed solely to lift the vibrator only Users should not under any circumstance use the lifting point on the vibrator to lift any other plant or machinery that the vibrator may be mounted to WARN...

Страница 4: ...Page 3...

Страница 5: ...0x1 5 6H BLz22 5 2 400 130 100 M20x1 5 6H BLz22 5 4 350 121 100 M20x1 5 6H BLz22 2 2 6 150 112 100 M20x1 5 6H BLz24 8 2 500 130 120 M20x1 5 6H BLz24 10 2 500 130 120 M20x1 5 6H BLz24 13 2 500 130 120...

Страница 6: ...6 4000 122 110 M25x1 5 6H BLz50 35 8 3300 100 90 M25x1 5 6H BLz50 45 8 3300 100 90 M25x1 5 6H BLz50 55 8 3300 100 90 M25x1 5 6H BLz50 57 8 3300 100 90 M25x1 5 6H BLz60 95 4 7750 130 120 M32x1 5 6H BLz...

Страница 7: ...31850 28660 BLz 50 55 4 5500 53955 NJ 2315E TVP2 C3 49060 44150 40710 36640 BLz 50 65 4 6500 63765 NJ 2317E M1A C3 42800 38520 35500 31950 BLz 50 75 4 7500 73575 NJ 2317E M1A C3 32040 28830 26580 2392...

Страница 8: ...13E TVP2 C3 100000 90000 BLz 50 35 8 3500 34335 NJ 2315E TVP2 C3 100000 90000 BLz 50 45 8 4500 44145 NJ 2315E TVP2 C3 100000 90000 100000 90000 BLz 50 55 8 5500 53955 NJ 2317E TVP2 C3 100000 90000 BLz...

Страница 9: ...AGE TO THE VIBRATOR Fixing bolt tightening Use Grade 8 8 bolts with Grade 8 self locking nuts torqued to values below Figures below apply to un plated dry threads Where capscrews are used with locking...

Страница 10: ...ug in the cable entry hole BLz Vibrators are suitable for a 3 phase 50Hz or 3 phase 60Hz electrical supply BLz vibrators are rated for continuous duty The insulation class of the winding will be eithe...

Страница 11: ...3 Phase 50 60 Hertz The installer is directed to the diagram number engraved on the nameplate for the appropriate field connection diagram below Refer to nameplate for required connection L1 L3 are li...

Страница 12: ...0 65 75 4800 14 9 137 8 8 81 8 6 79 7 1 65 8 8 90 5 1 52 BLz60 61 7750 22 3 241 13 4 145 12 9 140 10 4 113 13 1 193 7 6 112 BLz 75 10250 28 9 200 17 4 120 16 7 115 13 5 93 6 POLE 960 RPM BLz 03 70 0 8...

Страница 13: ...5 69 9 7 89 6 3 58 BLz 60 61 7750 21 8 236 11 3 122 11 0 119 14 0 151 9 1 99 BLz 75 10250 28 3 195 14 6 101 14 2 98 18 3 127 11 8 82 6 POLE 1152 RPM BLz 03 70 0 9 0 92 0 41 0 45 0 41 0 46 0 55 0 6 0...

Страница 14: ...Page 13 BL03 TORQUE CURVES...

Страница 15: ...Page 14 BL05 15 TORQUE CURVES...

Страница 16: ...Page 15 BL20 22 TORQUE CURVES...

Страница 17: ...Page 16 BL24 25 TORQUE CURVES...

Страница 18: ...Page 17 BL30 TORQUE CURVES 2 4 POLE...

Страница 19: ...Page 18 BL30 6 POLE BL30 40 8 POLE TORQUE CURVES...

Страница 20: ...Page 19 BL40 TORQUE CURVES 2 4 POLE...

Страница 21: ...Page 20 BL40 TORQUE CURVES 6 8 POLE...

Страница 22: ...Page 21 BL45 TORQUE CURVES 2 4 POLE...

Страница 23: ...Page 22 BL45 TORQUE CURVES 6 8 POLE...

Страница 24: ...Page 23 BL50 TORQUE CURVES 4 POLE...

Страница 25: ...Page 24 BL50 TORQUE CURVES 6 8 POLE...

Страница 26: ...Page 25 BL60 TORQUE CURVES 4 6 POLE...

Страница 27: ...Page 26 BL60 125 6 BL75 6 POLE BL60 8 POLE TORQUE CURVES...

Страница 28: ...Page 27 BL75 TORQUE CURVES 4 8 POLE...

Страница 29: ...Page 28 BL80 TORQUE CURVES 6 8 POLE...

Страница 30: ...retighten screw Adjust opposite end to the same percentage Care should be taken when adjusting weights as unexpected shaft rotations can occur as clamp screws are loosened We recommend securing the o...

Страница 31: ...by suitable trained personnel in accordance with the applicable Code of Practice EN60079 19 Explosive atmospheres Equipment repair overhaul and reclamation The manufacturer offers a full repair servic...

Страница 32: ...tly to grip the shaft Smear the inner race with grease place the shaft rotor assembly carefully inside the stator bore within the main housing and fit the bearing housings outer grease retainers weigh...

Страница 33: ...C3 3 400 BLz 50 65 4 75 4 NJ 2317E M1A C3 CMA C3 3 000 BLz 50 75 6 55 8 57 8 NJ 2317E TVP2 C3 CP C3 3 000 BLz 60 95 4 NJ 2320E M1A C3 CMA C3 2 400 BLz 60 61 105 4 NJ 2320E M1A C3 CMA C3 2 400 BLz 60...

Страница 34: ...uter Grease Retainer 2 4 End Cover 2 5 Rotor Shaft Assy 1 6 O B Weight Assy 1 SET 7 Terminal Box Lid 1 8 Sealing Ring Terminal Box 1 8 Gasket Terminal Box 1 9 Grease Retaining Seal 2 10 Terminal Block...

Страница 35: ...Page 34 WARNING NAMEPLATE PSN 2255...

Страница 36: ...Page 35 EXAMPLE OF STANDARD VIBRATOR NAME PLATE Lz24 80...

Страница 37: ...Page 36 EXAMPLE OF STANDARD VIBRATOR NAME PLATE Lz03 22...

Страница 38: ...ole 72 0 24 2 Pole 73 8 75 4 Pole 86 8 4 Pole 66 2 6 Pole 85 6 6 Pole 60 8 8 Pole 82 0 25 2 Pole 67 9 80 6 Pole 90 0 4 Pole 61 9 8 Pole 90 0 6 Pole 62 8 Notes Noise levels measured with CEL573 sound l...

Страница 39: ...Check a That vibrator fixing bolts are correctly tightened and there is no damage to end covers preventing weights rotating b Bearings are not partially seized or over greased c Out of balance weight...

Страница 40: ...y requirements have been observed 1 1 1 1 1 2 1 1 3 1 1 5 1 3 1 1 3 2 1 3 3 1 3 4 1 3 7 1 3 8 1 3 9 1 4 1 1 5 1 1 5 2 1 5 4 1 5 5 1 5 6 1 5 7 1 5 8 1 6 1 1 6 2 1 6 4 1 7 1 1 7 2 1 7 3 1 7 4 Huw Willia...