Invicta ARATOS Скачать руководство пользователя страница 15

   ARATOS Wood stove     

  

reference 6453 44

 

 

 

Author: SP- 28/11/2018 

    

      Page 

7

 of  

 
 

 

 

Whatever the operating mode used (Rated power or Slow combustion), make sure each load of wood lights as soon 
as it is placed in the appliance and that it continues to burn. If this does not happen, open the “firing rate” control 
to the “lighting” position for a few moments until the wood lights properly:  

During the combustion phase of the volatile part of the wood , it is essential to avoid operation without 
full  fire,  failing  which  the  appliance  and  the  chimney  flue  will  be  soiled  and  effluents  harmful  to  the 
environment and health will be released into the atmosphere. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
Regulation controls: 

Systematically use the heat resistant glove supplied with the appliance to operate the controls which can be very hot. 

 

 

Firing  rate  control

:  Located  on  the  facade,  this  control  is  used  to  modulate  the  appliance  firing  rate  between  “Rated  power”  and 

“Extended combustion: see position on the diagram on page 8 
 

 

Lighting control

: Using the firing rate control beyond the “rated firing rate” position provides additional air for lighting.  This position is 

reserved for lighting and re-starting operations and must not be used for more than 30 minutes as this may cause damage to the appliance 
and its surroundings. The appliance must be kept under surveillance the entire time this position is used. 

 

 

Secondary air control

: This control should remain open for effective performance and clean combustion. Closing this control is only justified if 

the draught is higher than recommended (see above). It should never be completely shut. Once this adaptation has been made, do not use the 
secondary air control. Only use the firing rate control to vary the appliance power.

 This control cannot be completely shut: this makes sure the appliance 

cannot accidentally be deprived of secondary air with the unpleasant consequences this leads to (very deteriorated combustion that soils the appliance and the 
window with fast bistre and the flue being blocked).  

 

 

 

Primary 

air 

Post 

combustion 

air 

Clean 

window 

Dirty 

window 

Post combustion activated = 

GOOD 

“Hot and clean”  

appliance 

Flameless combustion =  

BAD

 

“Cold and dirty”  

appliance 

Bed of 

embers 

Содержание ARATOS

Страница 1: ...Po le bois ARATOS r f rence 6453 44 R dacteur SP le 28 11 2018 Page 1 sur 8 Po le bois ARATOS R f rence 6453 44...

Страница 2: ...sous l effet de la chaleur Si le cas se pr sente placer l appareil sur une dalle en b ton de largeur 100 cm longueur 100 cm paisseur 45mm recouverte d une face r fl chissante c t appareil plaque m tal...

Страница 3: ...es sur le sch ma ci dessous Si les parois avoisinantes sont en mat riaux incombustible et ne se d gradent pas sous l action de la chaleur la temp rature du mur pouvant atteindre 200 C ces dimensions...

Страница 4: ...Po le bois ARATOS r f rence 6453 44 R dacteur SP le 28 11 2018 Page 4 sur 8 3 4 7 14 12 13 15 16 21 23 25 32 26 31 34 35 36 28 27 38 37 39 2 1 5 6 8 9 17 20 22 29 30 33 15 13 19 18 15 15 11 24 14b 10...

Страница 5: ...60 4 12 RONDELLE RESSORT AV4170081 2 13 RONDELLE LL 6 AV4216250 6 14 GOUPILLE 6 x 25 AV6306250 1 14b GOUPILLE 6 x 30 AV6306300 1 15 ECROU BORGNE M6 AV7140060 10 16 ECROU A EMBASE M6 AV7220060 8 17 VIS...

Страница 6: ...e d air Il est possible de laisser la porte entre ouverte pour faciliter cette phase d allumage mais en maintenant toujours l appareil sous surveillance Fonctionnement Puissance nominale et combustion...

Страница 7: ...d allure au del de la position Puissance nominale permet d obtenir un suppl ment d air pour l allumage Cette position est r serv e aux op rations d allumage et de reprise et ne doit pas tre maintenue...

Страница 8: ...SP le 28 11 2018 Page 8 sur 8 Position combustion prolong e registre ferm en but e vers la gauche POSITIONS DU REGISTRE DE REGLAGE D ALLURE D tail commande de registre d air secondaire D tail commande...

Страница 9: ...ARATOS Wood stove reference 6453 44 Author SP 28 11 2018 Page 1 of 9 ARATOS Wood stove Reference 6453 44...

Страница 10: ...t could be damaged by heat If this occurs place the appliance on a 100 cm wide and 100 cm long concrete slab 45mm thick covered with a reflective surface on the appliance side stainless steel type pla...

Страница 11: ...gram below must be followed If the neighbouring walls are made from non combustible materials that are not damaged by heat the wall temperature can reach 200 C these distances can be reduced to 150 mm...

Страница 12: ...ARATOS Wood stove reference 6453 44 Author SP 28 11 2018 Page 4 of 9 3 4 7 14 12 13 15 16 21 23 25 32 26 31 34 35 36 28 27 38 37 39 2 1 5 6 8 9 17 20 22 29 30 33 15 13 19 18 15 15 11 24 14b 10...

Страница 13: ...RING WASHER AV4170081 2 13 WW 6 WASHER AV4216250 6 14 6 x 25 PIN AV6306250 1 14b 6 x 30 PIN AV6306300 1 15 M6 CAP NUT AV7140060 10 16 M6 FLANGE NUT AV7220060 8 17 TH M6x10 SCREW AV8406100 3 18 TH M6x2...

Страница 14: ...case reduce the air intake The door can be left partially open to facilitate the lighting phase in which case the appliance should be kept under surveillance Rated power and extended combustion operat...

Страница 15: ...g the firing rate control beyond the rated firing rate position provides additional air for lighting This position is reserved for lighting and re starting operations and must not be used for more tha...

Страница 16: ...rence 6453 44 Author SP 28 11 2018 Page 8 of 9 Extended combustion position control shut against the stopper on the left FIRING RATE CONTROL POSITIONS Secondary air control detail Primary air control...

Страница 17: ...nstallation doit avoir Une alimentation en air frais d di la combustion Une vacuation des produits de combustion L appareil et l installation doivent tre entretenus r guli rement Toutes les surfaces d...

Отзывы: