Inventus Power 57575-101 Скачать руководство пользователя страница 5

5

Charging

Many types of lead acid chargers are compatible with our U1LiFePRO™ batteries and safely 
charge between 0°C to 55°C (32°F to 131°F). The charger maximum voltage output should match 
the maximum charge voltage of the battery system and should not exceed constant voltage as 
shown in the table below. It is recommended to charge the battery prior to installation. Consult 
with Inventus Power for recommendation on selecting a battery charger. 

Charge Voltage / Current

Pin Definition

Pin Definition (M-12V40-U1)

Pin Definition (M-24V20-U1)

Model

M-12V40-U1

M-24V20-U1

Charge Voltage

14.4 VDC

28.0 VDC

Recommended Charge Current

20A (0.5C)

10A (0.5C)

Maximum Charge Current

40A (1.0C)

20A (1.0C)

 Pin #

Symbol

Description

1

SMBUS 

SMBDAT; leave floating when using CAN 

2

SMBUS 

SMBCLK; leave floating when using CAN

3

not used

4

VINTLK 

For charging, connect VGND to VINTLK

5

VWAKE 

For discharging, connect VGND to VWAKE

6

VGND

Ground Reference

7

VCANH_BATT

CAN High (Battery)

8

VCANL_BATT

CAN Low (Battery)

 Pin #

Symbol

Description

1

A-RS485

RS485 Data A; leave floating when using CAN

2

B-RS485

RS485 Data B; leave floating when using CAN

3

not used

4

VINTLK

For charging, connect VGND to VINTLK

5

VWAKE

For discharging, connect VGND to VWAKE

6

VGND

Ground reference

7

VCANH_BATT

CAN High (Battery)

8

VCANL_BATT

CAN Low (Battery)

Power and Communication Cables

Power cables are not included with the battery unless a integration kit is purchased. Choose the 
appropriate power cable size based on the system load requirements. Refer to ampacity table 
in User Manual when selecting power cables. If your application requires communication, please 
use any off-the-shelf cable that is compatible with RIA Connector P/N: AJT3518821-030.  

Содержание 57575-101

Страница 1: ...inventuspower com info inventuspower com 1 877 423 4242 Inventus Power Inc 1200 Internationale Parkway Woodridge IL 60517 Designed Manufactured by U1LiFePRO Quick Start Guide M 12V40 U1 M 24V20 U1...

Страница 2: ...d Technical Support If you have any technical questions regarding the U1LiFePRO battery please contact our technical support team at Phone 1 877 423 4242 E mail tech_support inventuspower com Release...

Страница 3: ...n Insulated Torque Wrench Philips Screwdriver Voltmeter If in doubt please consult with Inventus Power Technical Support tech_support inventuspower com on further instructions on the signal cable conn...

Страница 4: ...voltage to wake the battery from Shut down Mode 14 4V for 1s 28 0V for 1s M 12V40 U1 M 24V20 U1 TO WAKE UP THE BATTERY FROM SHIP MODE TO PLACE IN SHIP MODE We recommend to place the battery in Ship Mo...

Страница 5: ...CAN 2 SMBUS SMBCLK leave floating when using CAN 3 not used 4 VINTLK For charging connect VGND to VINTLK 5 VWAKE For discharging connect VGND to VWAKE 6 VGND Ground Reference 7 VCANH_BATT CAN High Ba...

Страница 6: ...attery 6 Attach the signal communications cable to the RJ45 ports if needed 7 If the battery charger is integrated with the device drawing power from the U1LiFePRO battery then please follow manufactu...

Страница 7: ...Mode Connect pins 5 6 to enter Discharge Mode 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Mode Name VWAKE VINTLK Action Mode Description Sleep Off High or Hi z Off High or Hi z Disconnect pins 4...