9.1 Indoor Unit Error Display
Operation
lamp
Timer lamp
Display
LED STATUS
☆
1 time
X
E0
Indoor unit EEPROM parameter error
☆
2 times
X
E1
Indoor / outdoor units communication error
☆
4 times
X
E3
Indoor fan speed has been out of control
☆
5 times
X
E4
Indoor room temperature sensor T1 open circuit or short
circuit
☆
6 times
X
E5
Evaporator coil temperature sensor T2 open circuit or
short circuit
☆
7 times
X
EC
Refrigerant leakage detection
☆
1 times
O
F0
Overload current protection
☆
2 times
O
F1
Outdoor ambient temperature sensor T4 open circuit or
short circuit
☆
3 times
O
F2
Condenser coil temperature sensor T3 open circuit or
short circuit
☆
4 times
O
F3
Compressor discharge temperature sensor T5 open
circuit or short circuit
☆
5 times
O
F4
Outdoor unit EEPROM parameter error
☆
6 times
O
F5
Outdoor fan speed has been out of control
☆
1 times
☆
P0
IPM malfunction or IGBT over-strong current protection
☆
2 times
☆
P1
Over voltage or over low voltage protection
☆
3 times
☆
P2
High temperature protection of compressor top
diagnosis and solution
☆
5 times
☆
P4
Inverter compressor drive error
O
(
light
)
X
(
off
)
☆(
flash
)
Содержание P7MVI-09WiFi
Страница 8: ...8 For P7MVI 09WIFI...
Страница 9: ...9 For P7MVI 12WIFI For P7MVI 18WIFI...
Страница 10: ...10 For P7MVI 24WIFI...
Страница 11: ...11 3 2 Outdoor Unit...
Страница 14: ...14 For P7MVO 24...
Страница 16: ...16 P7MVO 09 P7MVO 12 16022000020169...
Страница 17: ...17 P7MVO 18 P7MVO 24...
Страница 18: ...18...
Страница 25: ...25 cap to a torque of 18N m Be sure to check for gas leakage...
Страница 64: ...Scan here to download the latest version of this manual wall mounted unit AIR CONDITIONING SYSTEMS...