30
6.7
How to Remove the Chassis assembly
CAUTION:
Because the 24K indoor unit is
relatively large and heavy, it must have two
persons to implement the following steps.
Step1:
Remove the left and right pipe cover.
Step2:
Remove the 5 screws A,B,C,D,E remove
support part F and G.
Note:
Screw E is behind the E-box by mistake for this
sample, you need to remove screw X, to lift the
E-box a little, Then you can remove the Screw
E.
This
problem
will
be
solved
before
mass-production.
Step3:
Open the E-box, to lose the fan motor and
louver motor connectors from the PCB.
Step4:
Press the locker H and I, to lose the indoor
from the installation plate, lift it a little and
pull out it along the direction indicated in
right image.
Note:
It is not necessary to remove the panel to
remove the Chassis assembly, in order to show
clearly inside, these pictures are without panel