1
4
Check after installation
Test operation
● Check according to the following requirement after finishing installation.
Items to be checked
Possible malfunction
Has the unit been installed firmly?
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage
test?
It may cause insufficient cooling
(heating) capacity.
Is heat insulation of pipeline sufficient?
It may cause condensation and water
dripping.
Is water drained well?
It may cause condensation and water
dripping.
Is the voltage of power supply
accord-
ing to the voltage marked on the
nameplate?
It may cause malfunction or damaging
the parts.
Is electric wiring and pipeline installed
correctly?
It may cause malfunction or damaging
the parts.
Is the unit grounded securely?
It may cause electric leakage.
Does the power cord follow the speci-
fication?
It may cause malfunction or damaging
the parts.
Is there any obstruction in the air inlet
and outlet?
It may cause insufficient cooling
(heating) capacity.
The dust and sundries caused during
installation are removed?
It may cause malfunction or damaging
the parts.
The gas valve and liquid valve of
connection pipe are open completely?
It may cause insufficient cooling
(heating) capacity.
1. Preparation of test operation
● The client approves the air conditioner.
● Specify the important notes for air conditioner to the client.
2. Method of test operation
● Put through the power, press ON/OFF button on the remote controller to start
operation.
● Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
● If the ambient temperature is lower than 16
℃
( )
, the air conditioner can’t
start
cooling.
61
℉
Содержание L3VO-18
Страница 2: ...1 6 7 8 8 9 10 13 13 14 14 15 17 R410A R32 125 50 50 2087 5...
Страница 3: ...1 adaptor 8...
Страница 4: ...2...
Страница 5: ...3 3...
Страница 6: ...NEC CEC 4...
Страница 7: ...5 Working temperature range...
Страница 8: ...6 DB WB C 32 23 43 26 27 24 18 15o C 43o C 15o C 24o C 20o C 24o C DB WB C...
Страница 9: ...7 50cm 50cm 30cm 200cm 30cm...
Страница 10: ...8 1 2 3 4 5 6 7 1 2 3 4 5 1 2 3 4 5 6 7 8 9 10 11 12 13 14...
Страница 11: ...9 1 2 3 4 5 6 7 8 9 10 NEC CEC 1 2 3 4 5 3 6 24K 18K 25A 16A...
Страница 12: ...10 1 2 3 3 2300W 5000W 6 6000W 8000W 8 10000W 16000W 10 1 2 1 2...
Страница 13: ...11 1 2 3 4 N m 6 9 52 12 16 19 30 40 45 55 60 65 70 75 15 20 1 handle 2 3 L L N N N 1...
Страница 14: ...12 2 1 10cm 2 U U 18K QD 24K QE kidney kidney 1 kidney kidney kidney 25 25 18k 24k 2 25 kidney 1 16mm...
Страница 15: ...13 1 2 3 0 1MPa 4 1 2 0 1MPa 5 6 2 7 Lo Hi allen 1 2...
Страница 16: ...14 1 2 ON OFF MODE AUTO COOL DRY FAN HEAT 16o C...
Страница 19: ...17 B E mm A mm 6 6 35 1 4 9 52 3 8 12 12 7 1 2 15 8 16 5 8 1 3 0 7 1 6 1 0 1 8 1 0 2 4 2 2...
Страница 56: ......