6
Cleaning and maintenance
CAUTION
Cleaning by children and persons with limited abilities.
Injury to body parts (rotating fan) and/or malfunction of the ventilation system!
• Cleaning/maintenance of the ventilation unit must not be carried out by children and/or persons
who are not fully capable of doing so due to their physical, sensory or mental capabilities,
inexperience or lack of knowledge. Young children should be supervised to ensure that they do
not play with the unit.
The iV-Compact ventilation units and the sMove controller are virtually maintenance-free.
Any necessary cleaning or maintenance work can be carried out by the user by following these
instructions.
TIP:
Before performing cleaning or maintenance tasks, disconnect the controller's power sup-
ply and put on gloves.
Detergents
NOTE
The plastic/glass surface of the inner panel is not scratch-resistant
and may be damaged.
• Do not use sand, soda, acid or chlorine-based cleaning agents.
A commercially available detergent in warm water can be used for cleaning. The following tools
may be used for cleaning:
• lint-free, soft cloth
• soft brush
• Vacuum cleaner
Recommended maintenance
The maintenance tasks and intervals listed here are recommended by inVENTer GmbH to
maintain the functionality and performance of the iV-Compact ventilation system.
Depending on requirements and/or air quality, your personal maintenance plan may deviate
from these recommendations.
Interval
Assembly
Maintenance activity
Cleaning from the interior room
Monthly
Pollen filter
Replace the contaminated pollen filter.
Inner cover
Clean the surface of the panel with a damp cloth.
Quarterly
Dust filter
Wash the dust filter with warm water and
detergent.
Or
Replace defective dust filters.
Interval
Assembly
Maintenance activity
Half-yearly
Thermal
accumulator
Remove the thermal accumulator and clean it
under running warm water.
Guiding vanes
Remove the guiding vanes from the fan.
Clean the guiding vanes using a soft brush or
under warm running water.
Reversible fan
Clean the fan blades with a brush.
Wall sleeve
Clean the surface of the wall sleeve with a damp
cloth.
Carbon filter
Replace the activated carbon filter.
Sound protector
Replace the sound protector.
Sound absorbing insert
Gently pat off the sound absorbing insert.
Yearly
Wind protection insert
Wash the wind protection insert with warm water
and detergent.
Inner cover base plate
Clean the surface of the base plate with a damp
cloth.
Cleaning from the exterior
Yearly
Exterior closure:
weather protection hood
Clean the surface of the protective hood with a
damp cloth.
Clean the protective grid on the upper and bottom
air outlet to ensure the fins between the louvres
are free.
6.1
Remove the inner cover panel
To clean and maintain the ventilation unit, first remove the panel of the inner cover.
Requirements: The ventilation unit is switched off.
►
Open the inner cover (
►
Press the side detent lugs inwards on the inner
cover base plate's spacers.
►
Pull the inner cover panel forwards.
Ensure
that all the spacers disengage.
►
Remove the inner cover panel from the front.
Ö
You have removed the panel of the inner cover.
CLICK