background image

User’s Manual

XC-RF812 Reader

12

6 Operating RFID Demo

Select “Yes” to install .NET Framework 2.0:

Figure 6-3

When the .NET Framework 2.0 installation is complete, the program enters 

“Ready to Install” phase (if.NET Framework 2.0 is installed, the program 

directly enters this phase). It takes a few seconds to finish, and then enters the 

“Installationshield Wizard” screen, as shown below:

Figure 6-4

Содержание XC-RF812

Страница 1: ...User s Manual XC RF812 Reader Invengo Information Technology Co Ltd ...

Страница 2: ...Thank you for using Invengo s RFID products We are glad that you ve chosen XC RF812 UHF RFID reader We hope our product will make your daily tasks at work easier ...

Страница 3: ...ision record as follows 9 June 2014 V1 0 10 March 2016 V1 1 10 May 2016 V1 2 or trademark belongs to Invengo All introduction and explanation on the product features as well as the functions and other related information written in this manual are the latest and accurate as at time of print The company reserves all rights to make any correction or amendment to this manual without prior notice and ...

Страница 4: ...meters Dimensions and Weight Structural Features and Working Principals Installation and Troubleshooting Operating RFID Demo Routine Maintenance FAQs and Troubleshooting Transport and storage Packaging and Un packing After sale Service and Contact ...

Страница 5: ... Warning sign Improper handling may cause damage to health Improper handling may result in equipment damage Notification sign If ignored it may result in unsuccessful operation If ignored it may result in undesired effect ...

Страница 6: ...y and protective measures 2 2 Performance Parameters 3 2 1 Features 3 2 2 Technical parameters 3 3 Dimensions and Weight 4 3 1 Dimensions 4 3 2 Weight 4 4 Structural Features and Working Principals 5 4 1 Overall structure and working principals 5 4 2 Bottom panel description 5 4 2 1 Panel 5 4 2 2 LED panel 6 4 3 PC and API requirements 7 4 3 1 PC 7 4 3 2 API 7 ...

Страница 7: ...1 6 1 Preparation before operating RFID Demo 11 6 2 Demo software application environment 11 6 3 Installing RFID Demo 11 6 4 Demo Software Operation 15 6 4 1 Start screen 15 6 4 2 Reader Configuration 17 6 4 3 Scan configuration 18 6 4 4 Issue mode configuration 19 6 4 5 Issue tag operation 21 7 Routine Maintenance FAQs and Troubleshooting 23 7 1 Routine maintenance 23 7 2 FAQs and troubleshooting...

Страница 8: ...ckaging and Un packing 25 9 1 Packaging 25 9 2 Un packing 25 10 After sale Service and Contact 26 10 1 After sale service 26 10 1 1 Reader information 26 10 1 2 Computer Information 26 10 2 Other matters 27 ...

Страница 9: ...t design and ease to use Figure 1 1 XC RF812 reader The XC RF812 reader supports ISO18000 6C 6B compliant tags and performs wireless communication with tags via antenna to achieve read and write data operation on to tags 1 2 Application scope The XC RF812 is a high performance UHF reader supporting ISO18000 6C 6B compliant tags manufactured by different vendors The reader has a built in antenna an...

Страница 10: ...60 o C Relative humidity 5 to 95 RH 25 o C Power supply Power adapter standard or other power supply options 5V to 6V 2A Power adapter technical specifications are as follows Material code 1080200010 AC input 100 to 240V 50 to 60Hz DC output 5V 4A MAX Operating temperature 0 oC to 40 oC Storage temperature 20 oC to 60 oC 1 6 Safety and protective measures Any radio transmitting equipment including...

Страница 11: ...chnical parameters Operating frequency US 902 75MHz 927 25MHz EU 865 7MHz 867 5MHz AU 920MHz 926MHz RW 902MHz 928MHz 915 4MHz 919MHz RF output power 24dBm 1 0dB maximum output power Frequency stability less than 10ppm Read range 0 to 6cm tag and user environment dependent Power Power adapter AC input 100 240V 50 60Hz DC output 5V 0 3V 4A other power supply option 5V to 6V 2A Network interface comm...

Страница 12: ... 3 1 Dimensions Figure 3 1 XC RF812 XC RF812 reader dimensions Metric 170 0mm x122 5mm x 30 5mm Not inclusive of accessories Imperial 6 69in x4 82 in x 1 20 in 3 2 Weight XC RF812 reader weight Metric Approximately 0 5kg Not inclusive of accessories Imperial Approximately 1 10 lb ...

Страница 13: ...it The RF unit sends the responding command according to tag types The tags receives command and returns responding messages which will be amplified and modulated by the reception circuit and sent to the decoding unit of baseband unit The decoded data is sent to PC via communication interface on the baseband unit The baseband unit performs tag data decoding and communication with the PC 4 2 Bottom...

Страница 14: ...2 ladder USB interface 3 DC power jack φ 5 pin DC power socket use output 5V 4A power adapter power supply 4 2 2 LED panel Figure 4 2 XC RF812 LED panel For the LEDs definitions see Table 4 1 Table 4 1 LED definitions Number Name Definitions POWER Power LED After applying power to XC RF812 this LED turns green RUN System running LED Flashing green LED indicates that the system is running ...

Страница 15: ... a host computer CPU Pentium 4 frequency 1 7GHz or higher Memory 512M Byte Hard drive 20G RS 232 interface or 10M 100M network interface Host computer operating system requirements Windows 2000 Service Pack 3 Windows Server 2003 Windows XP Service Pack 2 Windows 7 Windows 8 4 3 2 API NET API VC and JAVA dynamic link library RFID Reader Demo For more information see Programmer s Reference Manual an...

Страница 16: ...hat have no proper protection Please consult the manufacturers of relevant medical devices to avoid such event This equipment may also cause disturbance to other electronic equipment while it is in operation 5 2 Installation conditions Before installing the XC RF812 reader please carefully check the product is in good condition and the accessories are complete Please check the product and its acce...

Страница 17: ...m the XC RF812 reader by default is in standby mode The reader does not transmit power in the initialization and standby mode RF power amplifier is turned off and only operates after receiving read tag command from the PC or open amplifier command 5 3 Troubleshooting This section describes troubleshooting common problems in particular the general problems occur when the installation is not correct...

Страница 18: ...wo aspects structure and properties 5 4 1 Structure acceptance Check if the installation meets installation standards and if the equipment connection is secure Check if the reader is firmly fixed Check if the screws are tightened For additional information see Installation Notes 5 4 2 Performance Acceptance Check if the reader operates properly mainly from the following two aspects check if the re...

Страница 19: ...ovides NET Demo NET APIs and C APIs for users secondary development 6 2 Demo software application environment Software Windows 2000 Service Pack 3 Windows Server 2003 Windows XP Service Pack 2 Windows 7 VISTA system Hardware Minimum P4 1 7GHz PC CPU 512M or above memory and 20G hard drive 6 3 Installing RFID Demo RFID Demo V1 2 or higher version Note The Windows version RFID Demo is described in t...

Страница 20: ...2 0 Figure 6 3 When the NET Framework 2 0 installation is complete the program enters Ready to Install phase if NET Framework 2 0 is installed the program directly enters this phase It takes a few seconds to finish and then enters the Installationshield Wizard screen as shown below Figure 6 4 ...

Страница 21: ...User s Manual XC RF812 Reader 13 6 Operating RFID Demo Click Next Figure 6 5 Enter user name and organization and click on Next Figure 6 6 ...

Страница 22: ...XC RF812 Reader 14 6 Operating RFID Demo The default installation directory is E Invengo RFID Demo If required click on the button Change to select a directory and then click Next Figure 6 7 Click Install Figure 6 8 ...

Страница 23: ...re and you can establish a network port or a USB connection If the equipment s IP address is uncertain you can use the device s USB interface to establish a connection Before using USB communication you need to install the corresponding driver linux cdc acm inf After the installation is complete you can navigate My Computer Properties Hardware Device Manager Ports to view the virtual serial ports ...

Страница 24: ...sections 1 Upper section it displays software name and company Logo and includes two buttons used to switch between Demo mode and Issue mode 2 Central section reader configuration is on the left of Central section operation result is shown on the right Central section 3 Lower section the left part shows running messages for example whether the reader is connected successfully the right part shows ...

Страница 25: ...ing and query First connect the reader to the host computer via USB connection and click the pop up reader configuration dialog box on Reader Config as shown in 1 of Figure 6 12 Input reader IP information including IP address subnet mask and gateway Click on the Config Click on the Query to get network information 2 Serial port baud rate setting and query As shown in 2 of Figure 6 12 click on the...

Страница 26: ...tag read configuration double byte EPC Check the EPC to read the adaptive length of EPC number TID Check the TID and you can set the length of data to read UserData Check the UserData and you can set the length of data to be read 2 Tag filter Check tag filter In the drop down box select the EPC or TID Fill in the data of which the tag to be filtered And the tag with specified data content can be a...

Страница 27: ...RFID Demo 6 4 4 Issue mode configuration 1 Click Issue mode on the main screen as shown in Figure 6 14 Figure 6 14 2 Enter issue mode screen and click the Config button a pop up configuration dialog box appears as shown in Figure 6 15 Figure 6 15 ...

Страница 28: ...erval interval time for issue operation Attempts of issue operation set the number of attempts to performs issue operation after a failed issue operation 3 Once configured click on the Issue button and a pop up dialog box appears as shown in Figure 6 16 Figure 6 16 The Issue screen includes General and Advanced 6C modes The General mode includes EPC UserData and reserved block EPC Block write and ...

Страница 29: ...ixed ending Set a fixed data to be written on a tag memory bank Locking Encrypt the written data Get Data Get the written tag data source Reserved block Set Access Password Password is required to access tag memory Set Kill Password Password is required for kill tag operation 6 4 5 Issue tag operation When issue mode configuration as shown in Figure 6 4 4 is complete user can perform issue operati...

Страница 30: ...Manual XC RF812 Reader 22 Figure 6 17 Automatic Select Auto 1 write data on EPC memory block 2 Click Start and then put the tags on the reader field to perform write operation Figure 6 18 6 Operating RFID Demo ...

Страница 31: ... is 115200bps Unable to connect through Ethernet port The default IP address of the reader under factory setting is 192 168 0 210 If the host PC s IP address is in the same network segment which the reader s IP address is in for example 192 168 0 XXX the connection will be successful If the user forgot about the reader s IP address user can reconfigure the IP address of the reader that is connecte...

Страница 32: ... equipment will not be subject to violent collisions and excessive vibration rain erosion chemical corrosion and harmful gases 8 2 Storage Requirement The long term warehouse storage environment for the XC RF812 reader must fulfill the following conditions Ambient temperature 20o C to 60o C Relative temperature 5 to 95 RH No sudden temperature and humidity changes ambient air is not harmful or com...

Страница 33: ... in the table below Table 9 1 Accessories checklist No Item Unit Order Code Remark No 1 Output 5V 4A power adapter 1 Piece 1080200010 Standard 2 Three core 10A 250V 1 8m power cord 1 Piece 2200500026 Standard 3 RJ45 crossover cable 1 5m 1 Piece 2200300003 Standard 4 USB cable 1 Piece 2200300049 Standard 5 CD ROM 1 Piece Standard 6 Warranty Card 1 Sheet Standard 7 Product certification 1 Sheet Stan...

Страница 34: ...tallation of reader reader application software 10 1 2 Computer Information computer brand and model computer s processing speed and available memory serial port used computer operating system 10 2 Other matters If our customer service staff has confirmed with the user to return his her reader for maintenance our representative will present the user with a return merchandise authorization RMA Plea...

Страница 35: ...hese limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation I...

Страница 36: ...02 3909 Email invengo sales invengo sg Website www invengo sg US Invengo Technology Corp 2700 160 Sumner Blvd Raleigh NC 27616 USA Tel 1 919 890 0202 Toll Free 1 855 379 2725 Email sales invengo com Website www invengo com Europe Invengo Technology BV Belder 30 A 4704RK Roosendaal The Netherlands Tel 31 88 6363 793 Fax 31 88 6363 794 Email web invengo eu Korea Invengo International Pte Ltd Korea 3...

Отзывы: