background image

3   OVERVIEW

Part No. 1167458

13

Invacare® TheraPure™ Recessed Whirlpool Tubs

3.5

Dimensions

Models 3752G or 3802G

59.5”

17”

27”

5-1/2”

CL

47”

E

18”

31”

H

34”

C

6-1/2”

36”

41-1/2”

D

C H

8”

E

7”

21”

16”

21”

31-1/2”

Allo

w fo

r a

 40

” d

oo

r swing

C

3/4” Cold water stub with recommended shut off valve

D

2” Drain (floor drain recommended)

E

115V AC, 60 Hz, 15 A Input

H

3/4” Hot water stub with recommended shut off valve

Allow for 40” door swing (60” for wheelchair or lift access)

Содержание TheraPure 3752G

Страница 1: ...Manual EN This manual MUST be given to the user of the product BEFORE using this product read this manual and save for future reference Invacare TheraPure Recessed Whirlpool Tubs Model 3752G Model 38...

Страница 2: ...elines 6 Important Safety Information 6 3 OVERVIEW 8 Features 8 Product Labeling 10 Typical Product Parameters 11 Minimum Floor Space and Clearance Requirements 12 Dimensions 13 4 INSTALLATION 14 Prep...

Страница 3: ...ew 20 Cleaning and Disinfecting 21 Opening Closing the Tub Door 25 Waist Strap 27 Water Temperature Setting 28 Filling the Tub 29 Using the Shower Massage Wand 29 Using the Whirlpool Function 30 6 INS...

Страница 4: ...n imminently hazardous situation which if not avoided will result in death or serious injury WARNING Warning indicates a potentially hazardous situation which if not avoided could result in death or s...

Страница 5: ...consent C O D shipments will be refused please prepay shipping charges LIMITATIONS AND EXCLUSIONS THE WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR OR FAILURE TO ADHERE TO THE ENCLOSE...

Страница 6: ...lly designed and manufactured for use in conjunction with Invacare accessories Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invacar...

Страница 7: ...ir and body away from the jet assemblies when pump is running Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6 F...

Страница 8: ...tton Fill Button Push in once to auto fill push in and hold to add additional water to tub Water Temperature Thermometer Water Temperature Control Shower Massage ON OFF Button Door Tub Fill Spout Serv...

Страница 9: ...tton Push in once to auto fill push in and hold to add additional water to tub Water Temperature Thermometer Water Temperature Control Shower Massage ON OFF Button Door Tub Fill Spout Service Access D...

Страница 10: ...3 OVERVIEW Invacare TheraPure Recessed Whirlpool Tubs 10 Part No 1167458 3 2 Product Labeling Labels located inside the Service Access Door Label located on Interior Hardware...

Страница 11: ...eet x 6 feet Exterior Length Interior Length 59 1 2 inches 49 inches Exterior Width Interior Seat Width 31 1 2 inches 21 inches Deck Height 41 1 2 inches Side Access Door Swing 40 inches Volume Capaci...

Страница 12: ...ol Tubs 12 Part No 1167458 3 4 Minimum Floor Space and Clearance Requirements Models 3752G or 3802G 12 9 5 2 7 1 2 3752G OR 3802G RECESSED TUB ALLOW FOR A 40 DOOR SWING 4 11 1 2 TUB LENGTH 36 HOT AND...

Страница 13: ...5 1 2 C L 47 E 18 31 H 34 C 6 1 2 36 41 1 2 D CH 8 E 7 21 16 21 31 1 2 Allow for a 40 door swing C 3 4 Cold water stub with recommended shut off valve D 2 Drain floor drain recommended E 115V AC 60 Hz...

Страница 14: ...the service panels plumbing and electrical hookups CAUTIONS DO NOT lift the tub by the plumbing DO NOT modify the tub in any way Modifications to the system or any component may cause the system to ma...

Страница 15: ...or plan Refer to Minimum Floor Space and Clearance Requirements on page 12 The tubs are designed to be built in against one two or three walls much the same way a traditional tub shower unit is instal...

Страница 16: ...NCHES A Height of Motor Electrical Input 115V AC 60 Hz 15A plug 18 B Height of inch Hot Water Stub with Recommended Shut Off Valve 31 C Height of inch Cold Water Stub with Recommended Shut Off Valve 3...

Страница 17: ...cuit that is protected by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI...

Страница 18: ...b Refer to Operating Instructions on page 20 DANGER RISK OF SCALDING The hot water supply to the tub MUST NOT exceed 110 F 43 C to protect the user from scalding WARNINGS Be certain all plumbing work...

Страница 19: ...e is protected by a 15 AMP GFCI All water lines are checked for leaks ICCI skin care and cleaning products have been ordered To place your order call 800 668 2337 ICCI representative has been called t...

Страница 20: ...TIMES Recommended length of time spent in a bath is 5 to 10 minutes However if you or the person you are caring for becomes nauseated or dizzy or the person develops a headache get out of the tub at o...

Страница 21: ...he life of the door seal 5 2 Cleaning and Disinfecting WARNINGS Clean and disinfect the tub after EACH use to avoid resident infection and contamination of the tub DO NOT clean or disinfect the tub wh...

Страница 22: ...nto the footwell of the tub 4 Clean the pieces and spray all surfaces of the tub with Dispatch Cleaner and Disinfectant Take a long handled brush and thoroughly clean the interior surfaces of the tub...

Страница 23: ...osits Use a commercially available cleaner such as Invacare Heavy Duty Cleaner Remove the jet assemblies Remove the impeller caps Thoroughly spray the exposed surfaces including the jet casings Use a...

Страница 24: ...ailable cleaner full strength for the intended application on all surfaces to be cleaned Allow the cleaner to remain in contact with surfaces for at least five minutes to as long as 12 hours Rinse off...

Страница 25: ...3 Lift up on the door handle and open the door Closing the Tub Door 1 Close the door 2 Push down on the door handle to lock the door into position 3 Lift the door handle to ensure the safety pin has e...

Страница 26: ...5 OPERATING INSTRUCTIONS Invacare TheraPure Recessed Whirlpool Tubs 26 Part No 1167458 Door Handle Safety Pin Door...

Страница 27: ...ist strap around the resident Secure the ends together with the plastic clasp 2 Adjust the straps for comfort as necessary The waist strap is a positioning guide only The strap is not designed for use...

Страница 28: ...the body reaches a level several degrees above the normal body temperature of 98 6 F The symptoms of hyperthermia include an increase in the internal temperature of the body dizziness lethargy drowsin...

Страница 29: ...ng the flow control 4 Adjust the shower spray by rotating the shower wand head 5 Turn the shower massage off by pressing the ON OFF button again DANGER RISK OF SCALDING Check that the water temperatur...

Страница 30: ...r use press the whirlpool button again to stop the whirlpool jets 4 Drain the tub completely 5 Transfer the resident from the tub 6 Clean and disinfect the tub including the door seal Refer to Cleanin...

Страница 31: ...safety pin properly engages the door Check that all labels are present and legible Replace if necessary Before Each Use Clean and Disinfect the tub Refer to Cleaning and Disinfecting on page 21 Ensur...

Страница 32: ...ater deposits in whirlpool jets Disassemble and clean whirlpool jets System is noisy Whirlpool jets are turned on without water completely covering the jet assemblies Turn off the whirlpool jets Add w...

Страница 33: ...6 INSPECTION AND TROUBLESHOOTING Part No 1167458 33 Invacare TheraPure Recessed Whirlpool Tubs 6 3 Maintenance Record DATE MAINTENANCE PERSON TYPE OF MAINTENANCE PERFORMED NOTES...

Страница 34: ...NOTES Invacare TheraPure Recessed Whirlpool Tubs 34 Part No 1167458 Notes...

Страница 35: ...NOTES Part No 1167458 35 Invacare TheraPure Recessed Whirlpool Tubs Notes...

Страница 36: ...care Trademarks are identified by and All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted Dispatch is a registered trademark of Clorox Industries...

Отзывы: