Scorpius
Service Manual
1654773~A
26
❖
If a check shows the wiring to be normal, but the charger still does not charge the battery pack, the
charger may need to be replaced.
Lead-Acid Battery Wiring Inspection:
1. Please follow the same steps as above to remove the battery pack.
2. The connectors inside the pack can then be checked.
a. Negative power output charging wire - check the position of
the negative electrode hole on the battery pack.
b. Positive series wiring (without electrode wire).
c. Negative series wiring (without electrode wire).
d. Positive power output charging wire - check the position of
the positive electrode hole on the battery pack.
e. Charger socket power cable.
❖
Repair of the lead-acid battery is generally the same as for the
lithium battery. Except that
Removal provides special instructions for the removal and replacement of each kind of battery. For the
rest of the repair steps, refer to
SERVICE-06-1 Battery Pack - Charger
•
When turning the battery pack over, do not drop it, or put it down hard on the table. Place it
down gently and avoid damage. Damage to a lithium battery may cause a serious accident.
•
Step 6. After removing the battery main cable connector, remember that the battery end is
still electrically connected. Put it down carefully and make sure there is no chance of a short
circuit.
•
Do not attempt to modify or repair the lithium battery inside the battery pack. This can be
very dangerous and represents a severe hazard.
•
During the replacement of the battery pack, please remove the battery and prevent
operation on the scooter directly to facilitate the replacement.