Страница 1: ...cto V Oxygen Concentrator IRC5PO2VAW en HomeFill System Compatible User Manual This manual MUST be given to the user of the product BEFORE using this product this manual MUST be read and saved for fut...

Страница 2: ...m Invacare Trademarks are identified by and All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted Making Life s Experiences Possible is a registere...

Страница 3: ...ning the Nasal Cannula 23 6 3 3 Turning the Concentrator On 25 6 3 4 Flowrate 26 6 3 5 SensO2 Oxygen Purity Indicator 27 6 3 6 Initial Startup of the Concentrator 27 6 3 7 Explanation of Oxygen Purity...

Страница 4: ...cates a potentially hazardous situation which if not avoided may result in property damage or minor injury or both Gives useful tips recommendations and information for efficient trouble free use Symb...

Страница 5: ...ical Hazard Manufacturer Call supplier This product complies with Directive 93 42 EEC concerning medical devices The launch date of this product is stated in the CE declaration of conformity EC Repres...

Страница 6: ...product if the patient is capable of spontaneous breath able to inhale and exhale without the use of a machine DO NOT use in parallel or series with other oxygen concentrators or oxygen therapy device...

Страница 7: ...is not intended to sustain or support life The oxygen concentration level of the output gas ranges from 87 to 95 6 The oxygen is delivered to the patient through the use of a nasal cannula The Invaca...

Страница 8: ...t the base B Specification Label is located on the back of the concentrator at the base C EU Representative label is located on the base D Phthalate label is located on the base E 2 2 General Guidelin...

Страница 9: ...ire Textiles oil or petroleum substances grease greasy substances and other combustibles are easily ignited and burn with great intensity in oxygen enriched air and when in contact with oxygen under p...

Страница 10: ...tricity created by any type of friction Keep the oxygen tubing cord and concentrator out from under such items as blankets bed coverings chair cushions clothing and away from heated or hot surfaces in...

Страница 11: ...chemicals from airway contamination DO NOT use the concentrator in the presence of pollutants smoke fumes flammable anesthetics cleaning agents or chemical vapors WARNING Risk of Injury or Death To pr...

Страница 12: ...adversely affect the flowrate and the percentage of oxygen and consequently the quality of therapy WARNING Risk of Injury or Damage Invacare oxygen concentrators are specifically designed to minimize...

Страница 13: ...c interference in a typical home healthcare environment Use of this equipment in an environment with higher levels of interference could affect the accuracy of the oxygen concentration being delivered...

Страница 14: ...xygen Concentrator 3 Components 3 1 Component Identification A Oxygen Outlet B Flowmeter C Elapsed Time Meter D Oxygen Purity Indicator Lights Fault and Power Indicator Lights E Circuit Breaker F Powe...

Страница 15: ...HomeFill Home Oxygen Compressor The outlet fitting does not affect concentrator performance Refer to the HomeFill System user manual for connection and operating instructions When not in use the plug...

Страница 16: ...Invacare Perfecto V Oxygen Concentrator 3 2 Pneumatic Diagram Fig 3 1 Concentrator without Humidifier Fig 3 2 Concentrator with Humidifier 16 1195056 B...

Страница 17: ...ns to reduce the propagation of fire in the accessories for the safety of the patient and others If a commercially available fire activated flow stop device is used in the accessories setup it should...

Страница 18: ...arton Unless the oxygen concentrator is to be used IMMEDIATELY leave concentrator in its packaging for storage until use is required 5 2 Inspection 1 Inspect examine exterior of the concentrator for n...

Страница 19: ...injury during therapy The oxygen concentrator MUST be placed on a level surface for use DO NOT relocate the oxygen concentrator while in use WARNING Risk of Injury or Damage To avoid injury or damage...

Страница 20: ...Connect Humidifier if so prescribed 6 3 1 Setting Up the Humidifier If Prescribed WARNING Risk of Injury or Damage To avoid burns from steam or hot water inhalation of water and or water damage to the...

Страница 21: ...er Boil tap water for approximately 10 minutes and cool to room temperature prior to use CAUTION Risk of Damage Confirm the humidifier cap is not cross threaded on the humidifier bottle 3 Insert a fla...

Страница 22: ...r K on the concentrator If using the optional accessory Humidifier Bottle Holder M1521 to position humidifier at patient side location place the accessory on a flat surface as close to the patient as...

Страница 23: ...tubing Close supervision is necessary when the nasal cannula is used by impaired individuals or near children and or impaired individuals WARNING Risk of Injury or Death To reduce the risk of injury...

Страница 24: ...pply tube B to the humidifier bottle outlet M For use without a humidifier bottle Attach the patient s nasal cannula supply tube B to the oxygen outlet connector K on the concentrator 4 After assembly...

Страница 25: ...d look for bubbles indicating proper operation Wipe any excess water off the nasal prongs when finished before placing on the patient If there are no bubbles check all connections including humidifier...

Страница 26: ...lly reassessed Use only the tubing and accessories that were used to determine the prescribed oxygen flow setting Do not set the flow above the RED ring An oxygen flow greater than 5 L min will decrea...

Страница 27: ...dicator This feature monitors the purity of oxygen generated by the oxygen concentrator If purity falls below factory preset standards indicator lights on the control panel will illuminate 6 3 6 Initi...

Страница 28: ...light with YELLOW light flashing Immediately call supplier Oxygen sensor is malfunctioning You may continue to use the concentrator Symbol O2 Purity Indicator Light LED Explanation C SYSTEM FAILURE O...

Страница 29: ...of the concentrator To avoid damage or injury from electrical shock Turn Off the concentrator and unplug the power cord before cleaning DO NOT allow any cleaning agent to drip inside the air inlet and...

Страница 30: ...f Damage To avoid damage to the internal components of the unit DO NOT operate the concentrator without the filter installed or with a dirty filter There is one cabinet filter located on the back of t...

Страница 31: ...from infection or damage to concentrator Only qualified personnel should perform cleaning and disinfection of the oxygen concentrator and accessories between patients Follow these instructions to eli...

Страница 32: ...CHEDULE OR BETWEEN PATIENTS Every 3 years of continuous use Equivalent to 26 280 hours Check Oxygen Concentration green indicator light Clean Replace Cabinet Filter s Refer to Cleaning the Cabinet Fil...

Страница 33: ...orking towards ensuring that the company s impact on the environment locally and globally is reduced to a minimum We comply with the current environmental legislation e g WEEE and RoHS directives We o...

Страница 34: ...blem recurs use a different outlet 3 Push reset circuit breaker If problem recurs call service supplier Alarm System Failure RED light illuminated Continuous Concentrator not operating power switch On...

Страница 35: ...elow 0 5 L min use the Pediatric Flowmeter IRCPF16AW The use of the Pediatric Flowmeter will deactivate the Potential Obstruction Alert Alarm System Failure YELLOW light Illuminated Short beeps long p...

Страница 36: ...7 to 95 6 at 0 5 to 5 L min 93 3 at 2 L min Concentration levels achieved after initial warm up period approximately 30 minutes Maximum Outlet Pressure 34 5 kPa 3 45 kPa 5 psi 0 5 psi Flow Range 0 5 t...

Страница 37: ...essure Alarm w compressor shutdown Battery Free Power Loss Alarm SensO2 Oxygen System Possible Obstruction Alert Width 38 1 cm 1 cm 15 in 3 8 in Height 58 4 cm 1 cm 23 in 3 8 in Depth 30 5 cm 1 cm 12...

Страница 38: ...Avoid deep pile carpets and heaters radiators or hot air registers Floor location only No confined spaces Example No closets Environment Smoke and soot free Tubing 2 1 m 7 ft cannula with a maximum 1...

Страница 39: ...ons flicker emissions IEC 61000 3 3 Complies The Device is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply...

Страница 40: ...nvironment If the user of the Device requires continued operation during power mains interruptions it is recommended that the Device be powered from an un interruptible power supply or a battery UT is...

Страница 41: ...ts W according to the transmitter manufacturer and d is the recommended separation distance in metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a sho...

Страница 42: ...RF communications equipment and the Device The Device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the Device can...

Страница 43: ...ency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer At 80 MHz and 800 MHz the separation distance for the higher...

Страница 44: ...e Poirier SAS Route de St Roch F 37230 Fondettes Tel 33 0 2 47 62 64 66 Fax 33 0 2 47 42 12 24 contactfr invacare com www invacare fr Ireland Invacare Ireland Ltd Unit 5 Seatown Business Campus Seatow...

Страница 45: ...z Suisse Svizzera Invacare AG Benkenstrasse 260 CH 4108 Witterswil Tel 41 0 61 487 70 80 Fax 41 0 61 487 70 81 switzerland invacare com www invacare ch United Kingdom Invacare Limited Pencoed Technolo...

Страница 46: ...Notes...

Страница 47: ...Notes...

Страница 48: ...3 Tel 800 832 4707 www invacare com Manufacturer Invacare Corporation 2101 E Lake Mary Blvd Sanford FL 32773 United States Tel 407 321 5630 EU Representative Invacare Deutschland GmbH Kleiststra e 49...