background image

8.3.1 How the mobility device is anchored in a vehicle

for use as a vehicle seat . . . . . . . . . . . . . . . . . . . . . . 70

8.3.2 How the user is secured within the mobility

device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

8.4 Disassembling the mobility device for transport . . . . . . . . 72

8.4.1 Folding the backrest forwards . . . . . . . . . . . . . . . . . . 73
8.4.2 Disconnecting the remote . . . . . . . . . . . . . . . . . . . . . 74
8.4.3 Removing/Installing the seat . . . . . . . . . . . . . . . . . . . 74
8.4.4 Removing/Installing the battery boxes . . . . . . . . . . . . 75
8.4.5 Folding/Unfolding the chassis . . . . . . . . . . . . . . . . . . . 76

8.5 Reassembling the mobility device . . . . . . . . . . . . . . . . . . 76

9 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77

9.1 Maintenance introduction . . . . . . . . . . . . . . . . . . . . . . . . 77
9.2 Cleaning the mobility device . . . . . . . . . . . . . . . . . . . . . . 77
9.3 Inspection checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77

9.3.1 Before each use of the mobility device. . . . . . . . . . . . 77
9.3.2 Weekly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
9.3.3 Monthly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78

9.4 Wheels and tires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
9.5 Short-term storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
9.6 Long-term storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

10 After Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

10.1 Reconditioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
10.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

11 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

11.1 Resetting the circuit breaker . . . . . . . . . . . . . . . . . . . . . 82

12 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83

12.1 Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . 83

13 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89

13.1 Inspections performed. . . . . . . . . . . . . . . . . . . . . . . . . . 89

Содержание Fox

Страница 1: ...Invacare Fox en Power Wheelchair User Manual This manual MUST be given to the user of the product BEFORE using this product read this manual and save for future reference ...

Страница 2: ...cation duplication or modification in whole or in part is prohibited without prior written permission from Invacare Trademarks are identified by and All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted ...

Страница 3: ... 2 2 Adjusting remote height 29 5 2 3 Adjusting the height of the remote only for swing away remote supports 29 5 2 4 Adjusting remote offset 29 5 2 5 Adjusting remote position 30 5 2 6 Swivelling the remote to the side 30 5 3 Adjusting the height of the armrests 30 5 4 Adjusting the width of the armrests 30 5 5 Adjusting the position of the armrest in depth 31 5 6 Adjustment options for the Modul...

Страница 4: ... Adjusting the height of the calf pad 54 5 15 Adjusting the head light 55 6 Usage 56 6 1 Driving 56 6 2 Before driving for the first time 56 6 3 Parking and stationary 56 6 3 1 Engaging Disengaging the parking brakes 56 6 4 Getting in and out of the mobility device 57 6 4 1 Removing the standard armrest in order to side transfer 57 6 4 2 Information about getting in and out 57 6 4 3 Folding away r...

Страница 5: ...8 4 5 Folding Unfolding the chassis 76 8 5 Reassembling the mobility device 76 9 Maintenance 77 9 1 Maintenance introduction 77 9 2 Cleaning the mobility device 77 9 3 Inspection checks 77 9 3 1 Before each use of the mobility device 77 9 3 2 Weekly 78 9 3 3 Monthly 78 9 4 Wheels and tires 79 9 5 Short term storage 79 9 6 Long term storage 80 10 After Use 81 10 1 Reconditioning 81 10 2 Disposal 81...

Страница 6: ...mation about the product for example product safety notices and product recalls contact your Invacare representative See addresses at the end of this document 1 2 Symbols in this manual In this manual hazard statements are indicated by symbols The symbols are accompanied by a signal word that indicates the severity of the risk WARNING Indicates a hazardous situation that could result in serious in...

Страница 7: ...d higher than 3 km h has been classified according to EN 12184 as a class B mobility product for indoor and outdoor areas It is therefore compact and agile enough for indoor areas but also able to overcome many obstacles in outdoor areas 1 6 Regulations The vehicle was successfully tested according to German and international standards as to its safety It satisfies the requirements according to Ro...

Страница 8: ...General Terms and Conditions of Business in the respective countries Warranty claims can only be made through the provider from whom the product was obtained 1 9 Service life We estimate a service life of five years for this product provided it is used in strict accordance with the intended use as set out in this document and all maintenance and service requirements are met The estimated service l...

Страница 9: ...e the mobility device in accordance with the instructions in this user manual Pay strict attention to the safety information WARNING Risk of injury if the mobility device is driven when ability to operate a vehicle is impaired by medication or alcohol Never drive the mobility device under the influence of medication or alcohol If necessary the mobility device must be operated by an attendant who i...

Страница 10: ...ure that the total weight of the mobility device including the user does not exceed the maximum permissible weight for the platform lift or winch if you are using WARNING Risk of falling out of the mobility device Do not slide forward on the seat do not lean forward between your knees do not lean backwards out over the top of the backrest for example to reach an object If a posture belt is install...

Страница 11: ...y hot CAUTION Risk of fire or breaking down due to electric devices being connected Do not connect any electric devices to your mobility device that are not expressly certified by Invacare for this purpose Have all electrical installations done by your authorized Invacare provider 2 2 Safety information on the electrical system WARNING Risk of death serious injury or damage Misuse of the mobility ...

Страница 12: ...strained or covered with non conductive materials so that they are not exposed to human contact or materials that could cause electrical shorts When cables with live pins have to be disconnected for example when removing the bus cable from the remote for safety reasons make sure to restrain or cover the pins with non conductive materials WARNING Risk of death serious injury or damage Corroded elec...

Страница 13: ...ly Risk of damage to the mobility device A failure in the electric system can lead to unusual behavior such as continuous light no light or noises from the magnetic brakes If a failure exists switch off the remote and switch it on again If a failure still exists then disconnect or remove the power source Depending on the mobility device model you can either remove the battery packs or disconnect t...

Страница 14: ...the vehicle in any way can make it susceptible to electromagnetic interference Keep in mind that there is no sure way to determine the effect such modifications will have on the overall immunity of the electronic system Report all occurrences of unintentional movement of the vehicle or release of the electric brakes to the manufacturer 2 4 Safety information on driving and freewheel mode DANGER Ri...

Страница 15: ...to 12 Technical Data page 83 and information about overcoming obstacles in 6 5 Taking Obstacles page 58 Avoid shifting your center of gravity as well as abrupt joystick movements and changes of direction when the mobility device is in motion WARNING Risk of injury if the mobility device tips over continued Never use the mobility device to transport more than one person Do not exceed the overall ma...

Страница 16: ...as doorways and entrances Drive through narrow passages in the lowest driving mode and with due caution WARNING Risk of injury If your mobility device has been fitted with elevating legrests there is a risk of personal injury and damage to the mobility device if you drive the mobility device with the legrests raised To avoid unwanted displacement of the mobility device center of gravity to the fro...

Страница 17: ...d or service MUST be performed by a qualified technician Contact a provider or Invacare technician CAUTION Risk of accident and loss of warranty if maintenance is insufficient For reasons of safety and in order to avoid accidents which result from unnoticed wear it is important that this mobility device undergoes an inspection once every year under normal operating conditions see inspection plan c...

Страница 18: ...ditions and accessory parts which have been approved by Invacare for this mobility device Seating systems which are not approved by Invacare for use with this mobility device do not under certain circumstances comply with the valid standards and could increase the flammability and the risk of skin irritation Only use seating systems that have been approved by Invacare for this mobility device Elec...

Страница 19: ...mplete product The CE marking is invalidated if components or accessories are replaced or added that have not been approved for this product by Invacare In this case the company that adds or replaces the components or accessories is responsible for the conformity assessment CE marking or for registering the mobility device as a special design and for the relevant documentation Important informatio...

Страница 20: ...r use as a vehicle seat D Battery wiring diagram under the battery box cover E Identification label sticker on the rear post For details see below Warning that the mobility device may not be used as a vehicle seat This mobility device does not satisfy the requirements of ISO 7176 19 F Identification of the position of the coupling lever for driving and push operation not visible in the picture For...

Страница 21: ... in the CE declaration of conformity This product has been supplied from an environmentally aware manufacturer This product may contain substances that could be harmful to the environment if disposed of in places landfills that are not appropriate according to legislation The crossed out wheelie bin symbol is placed on this product to encourage you to recycle wherever possible Please be environmen...

Страница 22: ...s both motors must always be engaged This symbol indicates the Push position of the coupling lever In this position the motor is disengaged and the motor brakes are not operational The mobility device can be pushed by an attendant and the wheels turn freely Note that the remote must be switched off Also note the information provided in section 6 8 Pushing the mobility device in freewheel mode page...

Страница 23: ...ber F Drive wheel G Levers for disengaging motors at the rear not visible in the picture 3 2 Remotes Your mobility device may be fitted with one of several different remotes For information on the different functions and how to operate a particular remote refer to its corresponding user manual enclosed 1577074 F 23 ...

Страница 24: ... mentioned below please ensure that you have received the manufacturer s documentation with regard to correct fitting and use Belt with metal buckle adjustable both sides Belt can be adjusted on both sides This means that the buckle can be centrally positioned Belt with plastic buckle adjustable both sides Belt can be adjusted on both sides This means that the buckle can be centrally positioned 4 ...

Страница 25: ... transport on the user s lap for example can cause injury to the user or other persons During transport walking canes or crutches should always be secured using a cane holder 1 Open the upper hook and loop fastener 2 Place the lower end of the walking cane or the crutches in the container at the bottom 3 The walking cane or the crutches can be secured at the upper end using the hook and loop faste...

Страница 26: ...ed button and remove the accessory The adapter can turn in 90 steps allowing you to attach an accessory from any of four different directions Please refer to the installation instructions which are available from your Invacare provider or directly from Invacare More information on the KLICKfix system is available at http www klickfix com 26 1577074 F ...

Страница 27: ...ice and before use make sure that all attaching hardware is present and tightened securely WARNING Risk of injury or damage Incorrect set up of this mobility device performed by users caregivers or unqualified technicians can result in injury or damage DO NOT attempt to set up this mobility device Initial set up of this mobility device MUST be performed by a qualified technician Adjustment by the ...

Страница 28: ...ng pushed backwards during an accidental collision with an obstacle such as a doorframe or table and the joystick being jammed against the armpad if the position of the remote is adjusted and all screws are not completely tightened This will cause the mobility device to drive forward uncontrollably and potentially injure the mobility device user and any person standing in the way When adjusting th...

Страница 29: ...2 Adjust remote to desired height 3 Re tighten Allen screws 5 2 3 Adjusting the height of the remote only for swing away remote supports 6 mm Allen key 1 Loosen Allen screw A 2 Adjust remote to desired height 3 Re tighten Allen screw 5 2 4 Adjusting remote offset The remote can be adjusted in steps of 0 8 mm 20 mm sidewise 3 mm Allen key Fig 5 1 1 Loosen Allen screws A 2 Adjust remote to desired o...

Страница 30: ...the remote to the side If your mobility device is fitted with a swing away remote holder then the remote can be moved away to the side for example to drive up close to a table 5 3 Adjusting the height of the armrests 1 Loosen wing screw A 2 Adjust armrest to desired height 3 Re tighten wing screw 5 4 Adjusting the width of the armrests 8 mm Allen key 30 1577074 F ...

Страница 31: ...rest falls out of its bracket because it was pulled too far forward The armrest may be pulled forward out of the bracket as far as the point where the end of the inserted tube is flush with the rear of the bracket but no further 3 mm Allen key 1 Loosen screws A and move armrest in depth 2 Tighten screws securely 5 6 Adjustment options for the Modulite seat unit 5 6 1 Adjusting the height of the ar...

Страница 32: ...tted with red markings A and the word STOP The armrests must never be pulled out further than the point at which the word STOP is completely legible Always tighten the fixing screws properly once adjustments have been completed Depending on the side the screw is accessible from the front or the rear 8 mm Allen key 1 Loosen screw A 2 Adjust armrest to required position 3 Retighten the screw 4 Repea...

Страница 33: ... thumb screw 5 6 5 Adjusting the height following armrest Tools 5 mm Allen key 13 mm wrench 1 Loosen the screw A and nut B and remove them 2 Adjust armrest to desired height 3 Insert screw and nut and tighten 5 6 6 Changing the resistance flip up following armrest The movement of the flip up and following armrests can be set to have greater or less resistance Tools 5 mm Allen key 1577074 F 33 ...

Страница 34: ...llen key 5 6 7 Adjusting the arm pad angle flip up following armrest Tools 5 mm Allen key 1 Loosen screws A Do not remove them 2 Adjust arm pad to desired angle 3 Tighten screws 5 6 8 Adjusting the position of the arm pad of the flip up armrest 5 mm Allen key 1 Put the armrest in the vertical position 2 Release the interior bolts 1 with the Allen key 34 1577074 F ...

Страница 35: ...be operations that are not intended for the end user 5 6 10 Adjusting the seat depth Modulite seat unit The seat depth has a major influence on the selection of the center of gravity of the seat This impacts its dynamic stability If you make a major change to the seat depth the center of gravity of the seat must also be adjusted See Adjusting the center of gravity of the seat in the service instru...

Страница 36: ... 5 6 11 The hip support The hip support can be combined with the flip up armrest only Removing hip support 1 Pull lever A upwards 2 Remove hip support from holder Inserting hip support 1 Insert hip support in holder 2 Push lever A downwards Ensure that hip support locks with an audible click Adjusting position of hip support Tools 5 mm Allen key 1 Loosen screw A Do not remove it 2 Adjust hip suppo...

Страница 37: ... can adjust the width only smaller than the seat width but not wider 3 Tighten screws Adjusting angle of hip support Tools 5 mm Allen key 1 Loosen screws A 2 Adjust hip support to desired angle 3 Tighten screws Adjusting hip pad depth Tools 10 mm wrench 1577074 F 37 ...

Страница 38: ...You can adjust the hip pad height in two ways Via its mounting slots Via its bracket Via mounting slots Tools 10 mm wrench 1 Loosen the two screws A 2 Remove hip pad bracket from mounting slot via cut out B 3 Insert hip pad bracket in other mounting slot 4 Tighten screws Via bracket Tools 5 mm Allen key 38 1577074 F ...

Страница 39: ...lly trained service technicians and describe operations that are not intended for the end user 5 6 13 Adjusting the seat depth The seat depth has a major influence on the selection of the center of gravity of the seat This impacts its dynamic stability If you make a major change to the seat depth the center of gravity of the seat must also be adjusted See Adjusting the center of gravity of the sea...

Страница 40: ...ctly influences its dynamic stability For details regarding dynamic stability negotiating gradients and obstacles and the correct adjustment of seat tilt or backrest angle refer to 6 5 Taking Obstacles page 58 and 6 6 Driving up and down gradients page 60 10 mm open ended spanner 5 mm Allen key The possible seat angles are marked on a scale on the center post Depending on the rear seat height you ...

Страница 41: ...o 6 5 Taking Obstacles page 58 and 6 6 Driving up and down gradients page 60 CAUTION Risk of tipping if the backrest angle is set too far backwards for a seat on the rear seat position and with a seat depth larger than 460 mm When your seat with a seat depth larger than 460 mm is positioned on the rear seat position adjust the backrest angle to maximum 105 The backrest is fitted with a stopper all...

Страница 42: ... too far backwards for a seat on the rear seat position and with a seat depth larger than 460 mm When your seat with a seat depth larger than 460 mm is positioned on the rear seat position adjust the backrest angle to maximum 105 4 mm Allen key The backrest is fitted with a stopper allowing you to easily reset the backrest to your preferred backrest angle Adjusting the backrest is only possible be...

Страница 43: ...B and tighten 5 8 4 Adjusting the height of the backrest Modulite seat unit The following section describes the procedures for adjusting the height of the backrest plate The sling back is only available in fixed heights of 48 and 54 cm 5 mm Allen key 1 Loosen the backrest plate screws A and B Do not remove the screws 2 Move the backrest plate to the required height 3 Re tighten the screws 1577074 ...

Страница 44: ...in instructions for specially trained service technicians and describe operations that are not intended for the end user Note that if the sling back width is adjusted the backrest cushion must also be replaced 5 mm Allen key 1 Loosen and remove the backrest plate screw A 2 Loosen the backrest plate screws B Do not remove the screws 3 Move the backrest plate halves to the required width 4 Re insert...

Страница 45: ...A 2 Set the required backrest angle in 3 8 steps Use scale B on the backrest for this purpose Ensure that you set the same angle on both sides 3 Re insert and tighten the screw Ensure you insert the screw through one of the holes of the backrest bracket The screw must be visible on the inside of the bracket and the screw head must be flush with the bracket Simple backrest 6 mm Allen key 1 On both ...

Страница 46: ...djusting the headrest WARNING Risk of injury if the mobility device is used as a vehicle seat without a headrest This can cause the neck to be hyperextended during collisions It is recommended to use a headrest during transport The Invacare headrest for this mobility device available as an option is the perfect solution for use during transport The headrest must be adjusted to the user s ear heigh...

Страница 47: ...crew 5 9 2 Adjusting Height of Rea Headrest or Neckrest The adjustment of the height is the same for all Rea headrests and neckrests 1 Loosen hand screwA 2 Adjust headrest or neckrest to required height 3 Retighten hand screw 5 9 3 Adjusting the cheek supports 1 Push the cheek supports inward or pull them out to the required position 5 10 Adjusting Elan Headrest The headrest clamp hardware is desi...

Страница 48: ...ar height It may be necessary to remove and modify the back cushion cover in order to access the headrest mounting holes on the back pan An optional shim plate is available It may be installed between the clamp assembly and the back pan to provide additional spacing clearance on Posture Back and Deep Back 5 10 1 Adjusting Elan headrest hardware Elan headrest hardware is highly adjustable The illus...

Страница 49: ...ivot ball at the end of the headrest rod by loosening and tightening the mounting hardware 3 Loosen and remove lower D Ring E from hardware 4 Slide vertical mounting post B into clamp assembly and adjust overall height of headrest pad to desired position Tighten knob D For proper set up headrest should be adjusted to user s ear height 5 Adjust upper D Ring C as required 6 Once final height positio...

Страница 50: ... Adjusting the trunk supports 5 11 1 Adjusting the width 1 Loosen the knobs A that hold the lateral supports 2 Adjust the supports to the desired width 3 Re tighten the knobs 5 11 2 Adjusting the height 5 mm Allen key 1 Loosen the screws A that allow height adjustment of the lateral supports 2 Adjust the supports to the desired height 3 Re tighten the screws 5 11 3 Adjusting the depth 5 mm Allen k...

Страница 51: ...n wing screw 1 2 Adjust tray towards the left or right 3 Re tighten wing screw 5 12 2 Adjusting the depth of the tray removing the tray 1 Loosen wing screw A 2 Adjust tray to desired depth or remove it entirely 3 Re tighten screw 5 12 3 Swinging the tray away to the side The tray can be swivelled up and away to the side to allow the user to get in and out of the mobility device CAUTION Risk of inj...

Страница 52: ...2 Swivel the legrest inward or outward 3 To remove the legrest simply pull upward 5 13 2 Adjusting the length 5 mm Allen key 1 Loosen the screw 1 using the Allen key but do not remove completely 2 Set the legrest to the desired length 3 Re tighten the screw 5 14 Manually height adjustable legrest 5 14 1 Swivelling the legrest outward and or removing The unlocking knob is located on the top section...

Страница 53: ...erative to ensure that the legrests contact neither the caster wheels nor the ground 1 Press the unlocking lever 1 down Adjust the legrest to the required angle 2 Release the unlocking lever The legrest engages 5 14 3 Adjusting the length of the legrest CAUTION Risk of injury due to incorrect adjustment of the footrests and legrests Before and during every journey it is imperative to ensure that t...

Страница 54: ...pad The calf pad has four depth settings 4 mm Allen key 1 Swivel the calf pad to the front 2 Release bolt 1 with the Allen key and remove 3 Set the nut on the other side to the required depth 4 Adjust the calf pad to match the depth of the nut put the screw back in and tighten 5 14 5 Adjusting the height of the calf pad 54 1577074 F ...

Страница 55: ...ss or fog Before first usage you have to adjust the head light to prevent safety issues Adjust the head light so that you are seen well but do not dazzle other traffic Adjusting the head light correctly 1 Adjust the head light straight ahead 2 Measure distance between middle of head light and floor A 3 Mark vertical surface e g a wall which corresponds to half of determined value A 4 Distance betw...

Страница 56: ... yourself well with the operation of the mobility device and with all operating elements Take your time to test all functions and driving modes If installed make sure to properly adjust and use the posture belt each time you use the mobility device Sitting comfortably Driving safely Before each trip make sure that You are within easy reach of all operating controls The battery charge is sufficient...

Страница 57: ...device The armrest must be removed or swiveled up in order to get into or out of the mobility device from the side 6 4 1 Removing the standard armrest in order to side transfer 1 Pull the plug A of the remote cable to disconnect the remote 2 Loosen wing nut B 3 Remove the armrest from the holder 6 4 2 Information about getting in and out 1577074 F 57 ...

Страница 58: ...swivel it up 6 Now slide into the mobility device Getting out of the mobility device 1 Position your mobility device as close as possible to your seat 2 Align casters parallel to the drive wheels to improve stability during transfer 3 Always switch your mobility device off 4 Always engage both motor locks clutches and free wheel hubs if fitted to prevent the wheels from moving 5 Depending on the a...

Страница 59: ... obstacles also apply for attendants if the mobility device is fitted with an attendant control Fig 6 1 Right Fig 6 2 Wrong Ascending 1 Approach the obstacle or the curb slowly head on and at a right angle 2 Depending on the wheel drive type stop in one of the following positions a In the case of centrally driven mobility devices 5 10 cm before the obstacle b For all other drives approx 30 50 cm i...

Страница 60: ... the backrest of your seat or the seat tilt if adjustable seat tilt is available to an upright position before ascending slopes We recommend that you position the seat backrest or the seat tilt slightly to the rear before descending slopes Always lower the lifter if fitted to its lowest position before ascending or descending a slope Never attempt to ascend or descend a slope on slippery surfaces ...

Страница 61: ...ON Risk of the mobility device running away When the motors are disengaged for push operation whilst freewheeling the electromagnetic motor brakes are deactivated When the mobility device is parked the levers for engaging and disengaging the motors must without fail be locked firmly into the DRIVE position electromagnetic motor brakes activated The motors may only be disengaged by an attendant not...

Страница 62: ...ntrols system A specialized Invacare provider must perform the replacement You can find information on the fuse type in 12 Technical Data page 83 7 2 Batteries Power is supplied by two 12 V batteries The batteries are maintenance free and only need regular charging In the following you find information on how to charge handle transport store maintain and use batteries 7 2 1 General information on ...

Страница 63: ... manuals for your remote and battery charger for the position of the charging socket and further information about charging the batteries WARNING Risk of explosion and destruction of batteries if the wrong battery charger is used Only ever use the battery charger supplied with your mobility device or a charger that has been approved by Invacare WARNING Risk of electric shock and damage to the batt...

Страница 64: ...when storing We recommend to store batteries at a temperature of 15 C Gel and AGM batteries are maintenance free Any performance issues should be handled by a properly trained mobility device technician 7 2 6 Instructions on using the batteries CAUTION Risk of damaging the batteries Avoid ultra deep discharges and never drain your batteries completely Pay attention to the Battery Charge Indicator ...

Страница 65: ...ds This classification is based on the German GGVS Hazardous Goods Road Transport Ordinances and the IATA DGR Hazardous Goods Rail Transport Air Transport Ordinances Batteries may be transported without restrictions whether by road rail or by air Individual transport companies have however guidelines which can possibly restrict or forbid certain transport procedures Please ask the transport compan...

Страница 66: ...nt receptacle immediately after removing them Only ever transport damaged batteries in an appropriate acid resistant receptacle Wash all objects that have come into contact with acid with lots of water Disposing of dead or damaged batteries correctly Dead or damaged batteries can be given back to your provider or directly to Invacare 66 1577074 F ...

Страница 67: ...ehicle If a tray is fitted always remove it before transporting the mobility device 8 2 Transferring Mobility Device to Vehicle WARNING Mobility device is at risk of tipping over if transferred to a vehicle while user is still seated in mobility device Transfer mobility device without user whenever possible If mobility device with user must be transferred to vehicle using a ramp ensure that ramp d...

Страница 68: ...evice via lift turn off product and disconnect either bus cable from remote or batteries from system 1 Drive or push your mobility device into transport vehicle using suitable ramp 8 2 1 Locking Unlocking the caster locks CAUTION Risk of unexpected driving behavior due to locked casters If your mobility device is fitted with caster locks and these are locked the casters cannot move freely and the ...

Страница 69: ...e mobility device to use a vehicle seat and the safety belts provided with the vehicle The mobility device should always be anchored facing in the transport vehicle s intended direction of travel The mobility device must always be secured in accordance with the mobility device and anchoring system manufacturers user manual Always remove and secure any accessory parts fixed to the mobility device s...

Страница 70: ...e has undergone a crash test in which it was anchored in the transporting vehicle s direction of travel Other configurations were not tested The crash test dummy was secured using pelvic and upper body safety belts Both types of safety belt should be used in order to minimize the risk of injuries to head or upper body Invacare tests with a 4 point tie down system from Unwin Safety Systems Contact ...

Страница 71: ...They must not be held at a distance from the user s body using parts of the mobility device such as armrests or wheels Safety belts must be pulled as tightly as possible without causing the user discomfort Safety belts must not be positioned while twisted Ensure that the third seat belt anchorage point is not fixed directly to the vehicle floor but to one of the vehicle uprights WARNING Risk of in...

Страница 72: ... installed in the transporting vehicle should be applied as shown in the illustration above 1 Center line of the body 2 Center of the sternum 8 4 Disassembling the mobility device for transport CAUTION Injury hazard If you are unable to fasten your mobility device securely in a transport vehicle Invacare recommends that you do not transport it Your mobility device may be transported without restri...

Страница 73: ... under 5 Setup page 27 2 Fold the backrest forwards Refer to 8 4 1 Folding the backrest forwards page 73 3 Disconnect the remote Refer to 8 4 2 Disconnecting the remote page 74 4 Remove the seat if necessary Refer to 8 4 3 Removing Installing the seat page 74 You can leave the seat on the mobility device and move the mobility device like a trolley by tipping it on the antitippers 5 Remove the batt...

Страница 74: ... the remote 8 4 3 Removing Installing the seat CAUTION Risk of strains from lifting heavy parts Use proper lifting techniques Removing the seat 1 On the center post pull the safety latches A and fold up the seat until the rear safety latch B on the rear post engages The seat is now in the service position 2 74 1577074 F ...

Страница 75: ... Use proper lifting techniques Turn the front wheels at right angle to the driving direction to have more space when removing or installing the battery boxes Removing the battery boxes 1 On the battery box press down the safety latch A and pull the battery box up 2 Disconnect the battery box 3 Repeat STEPS 1 2 for the other battery box Installing the battery boxes Risk of pinching the battery cabl...

Страница 76: ... chassis 1 Pull the safety latch of the center post then pull the front of the chassis forward 2 Push down the lever of the curb climber to release it 3 Open the caster locks 8 5 Reassembling the mobility device Proceed as follows to reassemble the mobility device 1 Unfold the chassis Refer to 8 4 5 Folding Unfolding the chassis page 76 2 Install the battery boxes Refer to 8 4 4 Removing Installin...

Страница 77: ...ermitted disinfectants is available from the Robert Koch Institute at http www rki de 9 3 Inspection checks The following table lists inspection checks that should be performed by the user and their intervals If the mobility device fails to pass one of the inspection checks refer to the chapter indicated or contact your authorized Invacare provider A more comprehensive list of inspection checks an...

Страница 78: ...r damage and wear Contact your provider Removable legrests Check whether the legrests can be fixed securely and whether the loosening mechanism is properly operable Contact your provider Check that all adjustment options function properly Contact your provider Casters Check that casters rotate and swivel freely Contact your provider Drive wheels Check that the drive wheels rotate without wobbling ...

Страница 79: ...mended tire pressure see inscription on tire rim or contact Invacare Compare table below for conversion psi bar 22 1 5 23 1 6 25 1 7 26 1 8 28 1 9 29 2 0 psi bar 30 2 1 32 2 2 33 2 3 35 2 4 36 2 5 38 2 6 39 2 7 41 2 8 44 3 0 9 5 Short term storage In case a serious fault is detected a number of safety mechanisms are built into your mobility device and will protect it The power module prevents your...

Страница 80: ...power module if storing the mobility device longer than two weeks Depending on the mobility device model you can either remove the battery packs or disconnect the batteries from the power module Refer to the corresponding chapter about disconnecting the batteries If in doubt which cable to disconnect contact your provider Batteries should always be fully charged before storing If storing the mobil...

Страница 81: ...p page 27 10 2 Disposal The equipment wrapping is potentially recyclable The metal parts are used for scrap metal recycling The plastic parts are used for plastic recycling Electric components and printed circuit boards are disposed of as electronic scrap Exhausted or damaged batteries can be returned to your medical equipment supplier or Invacare Disposal must be carried out in accordance with th...

Страница 82: ...breaker ONLY replace with a circuit breaker of the same rating Resetting the circuit breaker may be needed if the mobility device does not turn on and the reset button has popped out about 6 mm 1 Switch off remote 2 To reset press the circuit breaker button A located on the rear of the battery box 82 1577074 F ...

Страница 83: ...d values may vary up to 10 mm Permissible operating and storage conditions Temperature range for operation according to ISO 7176 9 25 50 C Recommended storage temperature 15 C Temperature range for storage according to ISO 7176 9 25 65 C with batteries 40 65 C without batteries Electrical system Motors 2 x 200 W Batteries 2 x 12 V 50 Ah C20 leakproof AGM 2 x 12 V 45 Ah C20 leakproof AGM 2 x 12 V 4...

Страница 84: ...h 8 km h Min braking distance 400 mm 3 km h 1000 mm 6 km h 1500 mm 8 km h Rated slope2 Class A 3 km h 3 5 2 Class B 6 8 km h 6 10 5 according to manufacturer s specifications with 127 kg payload 4 seat angle 15 backrest angle Max climbable obstacle height 60 mm 100 mm with curb climber 80 mm with curb climber and Modulite seat Turning diameter 1600 mm short wheelbase 1630 mm extended wheelbase Piv...

Страница 85: ...570 mm backrest height 990 1090 mm telescopic seat frame moving the backrest plate Max total width component with widest point in parentheses 590 mm drive wheels 640 mm measured from outer edge of armrest at seat width 50 590 mm drive wheels 640 mm measured from outer edge of armrest at seat width 48 690 mm measured from outer edge of armrest at seat width 53 Total length incl standard legrests 93...

Страница 86: ...30 mm5 530 mm 530 580 mm5 Seat depth 400 430 460 490 mm 410 510 mm Backrest height4 490 570 mm 480 540 mm sling back 560 660 mm telescopic seat frame moving the backrest plate Seat cushion thickness 50 mm 50 75 100 mm Backrest angle 85 95 105 115 90 120 Armrest height 230 280 mm standard armrest 205 255 mm inrigged armest 245 310 295 360 mm telescopic seat frame with T armrest 275 340 325 390 mm o...

Страница 87: ...0 70 Weight5 Seat type Standard Modulite Curb weight approx 79 kg approx 94 kg Component weights Seat unit approx 23 kg Standard seat approx 28 kg Modulite seat Chassis approx 39 kg 45 50 Ah batteries approx 14 3 kg per battery 40 Ah batteries approx 14 5 kg per battery 34 Ah batteries approx 11 1 kg per battery Payload Max payload 127 kg 1577074 F 87 ...

Страница 88: ...fluenced by external factors such as the speed setting of the wheelchair the charging state of the batteries surrounding temperature local topography road surface characteristics tire pressure weight of user drive style and use of batteries for lighting servos etc The specified values are theoretical maximum achievable values measured according to ISO 7176 4 4 Measured without seat cushion 5 The a...

Страница 89: ...repair instructions have been properly performed The list of the inspection jobs to be performed can be found in the service manual which is available through Invacare Delivery Inspection 1st Annual Inspection Stamp of authorized provider Date Signature Stamp of authorized provider Date Signature 2nd Annual Inspection 3rd Annual Inspection 1577074 F 89 ...

Страница 90: ...authorized provider Date Signature Stamp of authorized provider Date Signature 4th Annual Inspection 5th Annual Inspection Stamp of authorized provider Date Signature Stamp of authorized provider Date Signature 90 1577074 F ...

Страница 91: ...Notes ...

Страница 92: ...nvacare ie New Zealand Invacare New Zealand Ltd 4 Westfield Place Mt Wellington 1060 New Zealand Phone 0800 468 222 Fax 0800 807 788 sales invacare co nz www invacare co nz United Kingdom Invacare Limited Pencoed Technology Park Pencoed Bridgend CF35 5AQ Tel 44 0 1656 776 222 Fax 44 0 1656 776 220 uk invacare com www invacare co uk Eastern Europe Middle East CIS Invacare EU Export Kleiststraße 49 ...

Отзывы: