background image

1   GENERAL

Part No. 1167456

5

Invacare® Supine Whirlpool Tubs

1.2

Limited Warranty

This warranty is extended only to the original purchaser/user of our products.
This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state.
Invacare Continuing Care, Inc. (ICC1) warrants its bathing/whirlpool products to be free from defects in materials and workmanship for a period of three 
years from the date of purchase. Warranty obligation is limited to parts replacement only. Warranty replacement parts are only covered for the duration of 
the warranty period. All purchased replacement parts will carry a 30-day warranty from the date of shipment. If within such warranty period any such 
product shall be proven to be defective, such product shall be repaired or replaced, at ICCI's option. This warranty does not include any labor or shipping 
charges incurred in replacement part installation or repair of any such product. ICCI's sole obligation and your exclusive remedy under this warranty shall be 
limited to such repair and/or replacement.
For warranty service, please contact the dealer from whom you purchased your ICCI product. In the event you do not receive satisfactory warranty service, 
please write directly to ICCI at the address below. Provide dealer's name, address, model number, date of purchase, indicate nature of the defect and, if the 
product is serialized, indicate the serial number.
ICCI will issue a return authorization. The defective unit or parts must be returned for warranty inspection using the serial number, when applicable, as 
identification within thirty days of return authorization date. DO NOT return products to our factory without our prior consent. C.O.D. shipments will be 
refused; please prepay shipping charges.
LIMITATIONS AND EXCLUSIONS: THE WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR OR FAILURE TO 
ADHERE TO THE ENCLOSED INSTRUCTIONS. LABOR; EXPENDABLE ITEMS, I.E. SHOWER HOSES, VALVES, “O” RINGS, SEALS; PARTS BROKEN 
DUE TO ABUSE OR IMPROPER USE; ITEMS THAT BECOME INOPERABLE DUE TO LACK OF MAINTENANCE, OR NON COMPATIBLE 
CHEMICALS; STAINS DUE TO HARD WATER, IODINE SOLUTIONS, OR OTHER UNAPPROVED CHEMICALS; “SPIDER” CRACKS OR 
“CRACKING” DUE TO MISHANDLING OR ABUSE. IN ADDITION, THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL NUMBERED 
PRODUCTS IF THE SERIAL NUMBER HAS BEEN REMOVED OR DEFACED; PRODUCTS SUBJECTED TO NEGLIGENCE, ACCIDENT, IMPROPER 
OPERATION, MAINTENANCE OR STORAGE; OR PRODUCTS MODIFIED WITHOUT ICCI'S EXPRESS WRITTEN CONSENT INCLUDING, BUT 
NOT LIMITED TO: MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR ATTACHMENTS: PRODUCTS DAMAGED BY 
REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE SPECIFIC CONSENT OF ICCI; PRODUCTS DAMAGED BY 
CIRCUMSTANCES BEYOND ICCI'S CONTROL; PRODUCTS REPAIRED BY ANYONE OTHER THAN AN ICCI DEALER, SUCH EVALUATION 
SHALL BE SOLELY DETERMINED BY ICCI.
THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES WHATSOEVER, WHETHER EXPRESS OR 
IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND THE SOLE 
REMEDY FOR VIOLATIONS OF ANY WARRANTY WHATSOEVER, SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE 
PRODUCT PURSUANT TO THE TERMS CONTAINED HEREIN. THE APPLICATION OF ANY IMPLIED WARRANTY WHATSOEVER SHALL NOT 
EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN. THE MANUFACTURER SHALL NOT BE LIABLE FOR 
ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER.
THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE/PROVINCIAL LAWS AND REQUIREMENTS.

PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW 
APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975.

Содержание 6302G

Страница 1: ...l DEALER This manual MUST be given to the user of the product USER BEFORE using this product read this manual and save for future reference EN Invacare Model 6302G Invacare Model 6302GADH Supine Whirl...

Страница 2: ...OVERVIEW 8 Features 8 Product Labeling 10 Typical Product Parameters 11 Minimum Floor Space and Clearance Requirements 13 4 INSTALLATION 14 Preparing the Work Area 14 Tub Dimensions and Connection De...

Страница 3: ...Setting 26 Filling the Tub 27 Using the Shower Massage Wand 27 Using the Whirlpool Function 28 Adjusting the Tub Height 6302GADH Only 28 6 INSPECTION MAINTENANCE AND TROUBLESHOOTING 29 Safety Inspect...

Страница 4: ...ly hazardous situation which if not avoided will result in death or serious injury WARNING Warning indicates a potentially hazardous situation which if not avoided could result in death or serious inj...

Страница 5: ...refused please prepay shipping charges LIMITATIONS AND EXCLUSIONS THE WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR OR FAILURE TO ADHERE TO THE ENCLOSED INSTRUCTIONS LABOR EXPENDABLE...

Страница 6: ...signed and manufactured for use in conjunction with Invacare accessories Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invacare prod...

Страница 7: ...98 6 F The symptoms of hyperthermia include an increase of the internal temperature of the body dizziness lethargy drowsiness and fainting The tub is specifically designed to be used with a bath lift...

Страница 8: ...No 1167456 3 Overview 3 1 Features Whirlpool ON OFF Button Fill Button Push in once to auto fill push in and hold to add additional water to tub Water Temperature Thermometer Water Temperature Control...

Страница 9: ...3 OVERVIEW Part No 1167456 9 Invacare Supine Whirlpool Tubs Whirlpool Jet Overflow Fill Spout Shower Massage Wand Shower Massage ON OFF Button Flow Control Valve Shower Spray Adjustment...

Страница 10: ...3 OVERVIEW Invacare Supine Whirlpool Tubs 10 Part No 1167456 3 2 Product Labeling Labels located inside the Service Access Door Label located on Interior Hardware...

Страница 11: ...41 inches 1041 mm 27 inches 686 mm Overall Tub Height Raised Lowered 56 inches 1422 mm N A N A 65 inches 1651 mm 51 inches 1295 mm Width Tub Exterior Tub Interior at Shoulder Tub Interior at Hip Tub...

Страница 12: ...gallons per minute 95 liters per minute Number of Jets 4 Electrical Classification Power Current Rating Class I Type B 115 VAC 60 Hz 7 Amps Tub Material Double wall gel coated fiberglass Thermometer 2...

Страница 13: ...3 OVERVIEW Part No 1167456 13 Invacare Supine Whirlpool Tubs 3 4 Minimum Floor Space and Clearance Requirements...

Страница 14: ...ion area MUST be able to support the 66 pounds per square inch 45 n cm load capacity of the tub Otherwise injury or damage might occur Access for servicing the tub MUST be provided Install the tub in...

Страница 15: ...10 254 mm from centerline 5 5 140 mm up from floor 3 4 Cold water stub with recommended shut off valve D 5 127 mm from centerline 29 736 mm from tub back edge 2 Drain floor drain recommended E 10 5 2...

Страница 16: ...Tub 1 Level the tub by adjusting the telescopic legs either up or down using a wrench to arrive at the desired height 2 Check to make sure the tub is level by placing a level on the front and sides of...

Страница 17: ...hat is protected by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI shoul...

Страница 18: ...iance with local codes Some state and local plumbing codes require the installation of a reduced pressure zone RPZ assembly on both the incoming hot and cold supply lines to prevent back flow contamin...

Страница 19: ...cordance with applicable building codes 7 Attach the shower massage wand and flow valve Be sure to use the washers supplied 8 Check for leaks in supply or drain lines and check operation of tub Refer...

Страница 20: ...n purged of any foreign matter Both hot and cold water lines are properly connected to the tub All water lines are checked for leaks Power line is protected by a 15 AMP GFCI ICCI skin care and cleanin...

Страница 21: ...re caring for becomes nauseated or dizzy or the person develops a headache get out of the tub at once and safely bring the body temperature back to normal 98 6 F Seek medical attention if symptoms or...

Страница 22: ...Tubs 22 Part No 1167456 Whirlpool ON OFF Button Fill Button Push in once to auto fill push in and hold to add additional water to tub Water Temperature Thermometer Water Temperature Control Tub Raise...

Страница 23: ...esident infection and contamination of the tub DO NOT clean or disinfect the tub when it is occupied Otherwise injury may occur Read and understand ALL information on disinfecting BEFORE use ALWAYS we...

Страница 24: ...ectant Lay the pieces in the footwell of the tub 4 Spray all surfaces of the tub with Dispatch Cleaner and Disinfectant Take a long handled brush and thoroughly clean the interior surfaces of the tub...

Страница 25: ...uct to wipe down all surfaces and allow the heavy duty cleaner to remain in contact with the exposed surfaces for approximately ten minutes Rinse off surfaces using the shower wand adjusted to spray p...

Страница 26: ...he effects of hyperthermia include Failure to perceive heat Failure to recognize the need to exit the spa or hot tub Unawareness of impending hazard Fetal damage in pregnant women Physical inability t...

Страница 27: ...trol 4 Adjust the shower spray by rotating the shower wand head 5 Turn the shower massage off by pressing the ON OFF button again The tub will fill to a predetermined level To stop the tub from fillin...

Страница 28: ...the stretcher lift to transfer the resident from the tub 7 Clean and disinfect the tub Refer to Cleaning and Disinfecting on page 23 5 7 Adjusting the Tub Height 6302GADH Only Perform one of the foll...

Страница 29: ...ore Each Use Clean and Disinfect the tub Refer to Cleaning and Disinfecting on page 23 Ensure that the maximum water fill temperature does not exceed 110 F 43 C Ensure that the maximum water pressure...

Страница 30: ...omassage System System will not start No electrical power to tub Check and reset breaker Switch air hose disconnected Reconnect hose to switch and controller System is ineffective Water deposits in wh...

Страница 31: ...eight Rub Panels and Glide Pads on page 30 Bad electrical connections no electrical power to tub Unplug the tub Check and reset GFCI Check electrical cord plug and outlet for damage Replace damaged pa...

Страница 32: ...ritten permission from Invacare Trademarks are identified by and All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted Dispatch is a registered tra...

Отзывы: