HEAD/FOOT BOARD   

OPTIONAL HEIGHT ADJUSTMENT

technician.

Electronics

Check all controls to make sure all functions work properly.

·

  Power cord

·

  Pendant cord

·

   Check to make sure all wires are routed and attached properly

so they do not interfere with any moving parts.

·

  Check to make sure all plugs are fully inserted or attached.

·

  Replace 9V battery annually or after each use.

Bed Frame and Sleeping Surface

Visually check all welds

·

  Head section

·

  Knee section

·

  Main Frame

·

   Check joints between sleeping surface sections for

loose fasteners.

Cleaning

 The metal parts of the bed are covered with a baked epoxy   

coating. Clean all coated parts with mild detergent and warm water.  

Periodically raise head and feet sections of the bed and remove  

dust from frame. Also, periodically remove the mattress and clean  

mattress deck. Perform cleaning as needed or between placements.

Lubrication and Mechanical

·

  Lightly grease all actuator screw threads with white lithium grease.

·

  Lubricate all caster roller and swivel bearings with light machine oil.

·

  Check all bolts and tighten as needed.

MAINTENANCE AND SAFETY CHECKS

Содержание 5410VC

Страница 1: ...Full Electric Value Care Bed User Manual Entrapment Guide For use with Item s 5410VC 5410VCDECK 5410VCHFB...

Страница 2: ...ant Operation 14 Head Footboard Optional Height Adjustment 15 Maintenance and Safety Checks 15 Electronics 15 Bed Frame and Sleeping Surface 15 Cleaning 15 Lubrication and Mechanical 15 Notice Indicat...

Страница 3: ...may result The maximum safe working load of this bed patient mattress bedding and accessories is 450lbs 204kg The maximum user weight is 350lbs 158kg ALWAYS observe the weight limits DO NOT stand or c...

Страница 4: ...2 away from any direct heat source Make sure head and foot springs sections are connected securely to the bed ends before use DO NOT use the bed to transport a person in or on the bed Otherwise injury...

Страница 5: ...plug the power cord from the junction box Damage to cord will result Use caution when disconnecting the pendant DO NOT press pendant buttons When bed is not to be used for an extended period unplug el...

Страница 6: ...ng B Head Spring C Head Board D Foot Board E Hi Low Shaft F Locking Pins 4 G Motor H Hand Crank attached to foot board for shipping I Casters 4 2 locking 2 non locking J Spring Clips 2 K Hand Pendant...

Страница 7: ...e h t e d i l S catches the rivet on the foot section Position head wing as shown h c a e o t n i n i p k c o l e m a r f a l l a t s n i l e v e l s n o i t c e s o w t e h t h t i W Be sure to prop...

Страница 8: ...ve shaft through hanger bracket Install Hi Low drive shaft to the Hi Low motor located on the foot section Insert the spring loaded side of the drive shaft into the lower receptacle as shown ASSEMBLY...

Страница 9: ...h bed on side extend the drive shaft until it reaches the full length of bed The drive shaft adjustment holes are marked for either semi or full beds Choose the full bed hole ASSEMBLY INSTRUCTIONS Fig...

Страница 10: ...ALWAYS install locking casters diagonally from each other Attach the head board and foot boards ALWAYS ensure that the 2 hooks on each side of the head and foot boards are fully engaged and seated sec...

Страница 11: ...spring loaded drive shaft on the hi low motor and insert the drive shaft into the gear box located on the footboard Make sure the slot on the spring loaded drive shaft fully engages the roll pin on t...

Страница 12: ...ow motor cables into motor as shown Connect a 9V battery not included to the battery clip located on the motor The battery clip is located in a recess under the motor cover With a charged battery inst...

Страница 13: ...towards the bed and lock on the actuator rod Repeat for foot section After the motor is fully installed slide both locking covers back onto the motor Once fully assembled and checked plug the unit in...

Страница 14: ...eration has been used to lower the bed Hand Crank The full electric bed is equipped with a removeable manual hand crank that may be used when either electric or battery power is unavailable WARNING AL...

Страница 15: ...ection Main Frame Check joints between sleeping surface sections for loose fasteners Cleaning The metal parts of the bed are covered with a baked epoxy coating Clean all coated parts with mild deterge...

Страница 16: ...ard panel frame a Headboard gear assembly b Footboard dear assembly 6 Sleep surface hook 7 Motor brackets 8 Hi Low motor gearbox 9 Caster set 2 locking 2 non locking 10 Caster receptacle 11 Frame link...

Страница 17: ...ars All other parts 3 year This device was built to exacting standards and carefully inspected prior to shipment This Limited Warranty is an expression of our our assurance to the end user of years of...

Страница 18: ...DL18 300UM A 2020 04 13 2020 Hangzhou Dunli Medical Instruments Co Ltd No 1 Dunli Road Renhe Street Yuhang Hangzhou Zhejiang 311107 China...

Отзывы: