background image

Page 1 / 6  

Page  /  Fitting and user guide for the  EEN-REC3 

 

V233-0013-AA receiver 

Fitting and user guide 

for the EEN-REC3 receiver 

 

 

Operating principle 

Overview: 

 

The  EEN-REC3  receiver  enables  control  of  two  car  park  accesses:  "ENTRY"  and  "EXIT",  and 
works with RF 868MHz 2 and 4-channel remote controls.  

 

Management of the remote controls is carried out on the internet.  

 

When controlling the 2 accesses, the anti-passback function is available using the switch settings.  

 

It is waterproof and can be attached to an outside wall. 

The RF 868 opens 2 doors, "ENTRY" and "EXIT": 

These 2 doors are controlled via 2 "CT" relays fitted to the receiver card.   
Pressing a button on the remote control will activate one of these two "ENTRY" or "EXIT" relays: 

Unlock time of the doors: The unlock time is set by the central unit.

 

Vehicle Detection: 

Activating each "ENTRY" / "EXIT" relay may depend on the use of vehicle detection loops. These 
loops can be set independently to "Normally Closed (NC)" or "Normally Open (NO)" using switches 
nos. 4 and 5 of the receiver (see switches and LED section below). 

Anti-Passback (only if activated on the  website and on the EEN-REC3 receiver): 

The  EEN-REC2  receiver  can  also  handle  anti-passback  conditions  (obligation  to  leave  before  re-
entering)  for  remote  controls  programmed  for  anti-passback  on  the  site.  This  handling  is  set  using 
switches 1, 2 and 3 (see switches and LED section below). 

Switch no. 6: For correct operation, it must always be set to OFF. 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Terminal 

blocks 

Switches 

Waterproof seal 

Waterproof cable pass 
through 

LEDs 

Содержание EEN-REC3

Страница 1: ...emote control will activate one of these two ENTRY or EXIT relays Unlock time of the doors The unlock time is set by the central unit Vehicle Detection Activating each ENTRY EXIT relay may depend on the use of vehicle detection loops These loops can be set independently to Normally Closed NC or Normally Open NO using switches nos 4 and 5 of the receiver see switches and LED section below Anti Pass...

Страница 2: ... The Switches and the LED Switches 1 2 and 3 define the time of the anti passback function or 2 minutes S1 S2 S3 Meaning OFF OFF OFF No anti passback handling ON OFF OFF Anti passback set to 5 minutes OFF ON OFF Anti passback set to 10 minutes ON ON OFF Anti passback set to 15 minutes OFF OFF ON Anti passback set to 30 minutes ON OFF ON Anti passback set to 45 minutes OFF ON ON Anti passback set t...

Страница 3: ...D P Supply As near as poss to central 12V 24V ______ D A A D EEN REC3 D D EEN MEDGE unit C T C T EEN REC3 RECEIVER Voltage free contact to device to control on entry exit Entry C1 T1 C2 T2 Exit P V POWER 2 1 ANT E 2 X 5A 24V entry exit Relays To detection of entry vehicle To detection of exit vehicle P V Presence Vehicle To central unit GSM alone 200 m max 0 50mm or 0 80mm twisted pair S D D BUS 2...

Страница 4: ...ication with the central unit and the central unit must indicate on the diagnostics screen that it has detected the receiver by displaying 1 RF example for connector No 1 in the Terminals section of the diagnostics screen If the receiver s LED is not on or 1 Free or 1 DEFAULT appears on the central unit s screen check the connections the voltage between the receiver s and terminals as shown on the...

Страница 5: ...ion Compliance with standards Limitations EC standards The RF 868Mh EEN REC3 receiver complies with the R TTE Directive 1999 5 EC electrical safety standard EN 60950 2000 applied EMC standard EN 301 489 3 2000 applied radio standard EN 300 220 3 2000 applied Cabling The cables used to connect the receiver to a central unit or GSM unit must be fitted in accordance with the instructions describing t...

Страница 6: ...Page 6 6 Page Fitting and user guide for the EEN REC3 V233 0013 AA receiver Sizes ...

Отзывы: