Page 1 / 6
Page / Fitting and user guide for the EEN-REC3
V233-0013-AA receiver
Fitting and user guide
for the EEN-REC3 receiver
Operating principle
Overview:
•
The EEN-REC3 receiver enables control of two car park accesses: "ENTRY" and "EXIT", and
works with RF 868MHz 2 and 4-channel remote controls.
•
Management of the remote controls is carried out on the internet.
•
When controlling the 2 accesses, the anti-passback function is available using the switch settings.
•
It is waterproof and can be attached to an outside wall.
The RF 868 opens 2 doors, "ENTRY" and "EXIT":
These 2 doors are controlled via 2 "CT" relays fitted to the receiver card.
Pressing a button on the remote control will activate one of these two "ENTRY" or "EXIT" relays:
Unlock time of the doors: The unlock time is set by the central unit.
Vehicle Detection:
Activating each "ENTRY" / "EXIT" relay may depend on the use of vehicle detection loops. These
loops can be set independently to "Normally Closed (NC)" or "Normally Open (NO)" using switches
nos. 4 and 5 of the receiver (see switches and LED section below).
Anti-Passback (only if activated on the website and on the EEN-REC3 receiver):
The EEN-REC2 receiver can also handle anti-passback conditions (obligation to leave before re-
entering) for remote controls programmed for anti-passback on the site. This handling is set using
switches 1, 2 and 3 (see switches and LED section below).
Switch no. 6: For correct operation, it must always be set to OFF.
Terminal
blocks
Switches
Waterproof seal
Waterproof cable pass
through
LEDs