background image

Page 1 / 6  

installation and user guide for the Intratone EEN-REC2   

V233-0011-AD receiver 

Installation and user guide 

for the EEN-REC2 receiver 

 

 

Operating principle 

Overview: 

 

The EEN-REC2 receiver and its aerial controls two car park accesses, "ENTRY" and "EXIT", and works 
with Intratone RF 868MHz 2 and 4-channel remote controls.  

 

Management of the remote controls is carried out on the 

www.intratone.com

website.  

 

When controlling the 2 accesses, the anti-passback function is available using the switch settings.  

 

The receiver can be installed on a DIN rail or wall-mounted. 

 

The RF 868 opens 2 doors, "ENTRY" and "EXIT": 

These two doors are controlled via two "CRT" relays fitted in the receiver card.   
Pressing a button on the remote control will activate one of these two "ENTRY" or "EXIT" relays: 
-

 

Channels I and III of the remote control trigger the receiver's ENTRY relay  

-

 

Channels I and III of the remote control trigger the receiver's EXIT relay 

 

 

 

 

 

 

Unlock time of the doors: 

The unlock time is set by the central unit, switch No. 7 can force it to 0.2 seconds (pulse). 

Vehicle Detection: 

Activating each "ENTRY" / "EXIT" relay may depend on the use of vehicle detection loops. These loops can 
be  set  independently  to  "Normally  Closed  (NC)"  or  "Normally  Open  (NO)"  using  switches  nos.  4  and  5  of 
the receiver (see switches and LED section below). 

Anti-Passback (only if activated on the www.intratone.com website and on the EEN-REC2 receiver): 

The EEN-REC2 receiver can also handle anti-passback conditions (obligation to leave before re-entering) for 
remote controls programmed for anti-passback on the site. This handling is set using switches 1, 2 and 3 (see 
switches and LED section below). 

Switch no. 6: For correct operation, it must always be set to OFF. 

 

 

 
 
 
 
 
 
 

 

 

C2: EXIT 

C1: 

ENTRY 

C4: EXIT 

C3: 

ENTRY 

Connection to Central Unit/GSM 
and Alarm 

8 switches 

Car park 
unitterminals 

Wall mounting 

or 

Clips on DIN 

rail 

 

LED

 

RF receiver 

EEN-REC2 

Intelligent Security & Fire Ltd.

Содержание EEN-REC2

Страница 1: ...and III of the remote control trigger the receiver s EXIT relay Unlock time of the doors The unlock time is set by the central unit switch No 7 can force it to 0 2 seconds pulse Vehicle Detection Activating each ENTRY EXIT relay may depend on the use of vehicle detection loops These loops can be set independently to Normally Closed NC or Normally Open NO using switches nos 4 and 5 of the receiver ...

Страница 2: ...s S1 S2 S3 Meaning OFF OFF OFF No anti passback handling ON OFF OFF Anti passback set to 05 minutes OFF ON OFF Anti passback set to 10 minutes ON ON OFF Anti passback set to 15 minutes OFF OFF ON Anti passback set to 30 minutes ON OFF ON Anti passback set to 45 minutes OFF ON ON Anti passback set to 60 minutes ON ON ON Permanent anti passback Switches 4 and 5 define the operation of the vehicle de...

Страница 3: ... As near as poss to central CODED AERIAL EEN REC2 RECEIVER Voltage free contact to device to control on entry Voltage free contact to device to control on exit Entrée R T C R T C Sortie P V POWER 2 1 ANT 200 m max 0 50mm or 0 80mm twisted pair C T R C T R A2 BUS D D A1 ALARM S E 2 X 5A 24V entry exit Relays SWITCHES ON 1 2 3 4 5 6 7 8 To detection of entry vehicle To detection of exit vehicle P V ...

Страница 4: ...an be connected to any other of the central unit s terminals only the terminal numbers change Once the receiver is correctly connected to the INTRATONE RESIDENTIAL central unit the unit s LED must be permanently on correct communication with the central unit and the central unit must indicate on the diagnostics screen that it has detected the receiver by displaying 1 RF example for terminal No 1 i...

Страница 5: ... standard EN 60950 2000 applied EMC standard EN 301 489 3 2000 applied radio standard EN 300 220 3 2000 applied Cabling The cables used to connect the receiver to an INTRATONE RESIDENTIAL central unit must be installed in accordance with the instructions describing the level 2 protected environment of the NF EN 61000 4 4 standard Please follow the recommendations given in the cabling and connectio...

Страница 6: ...Page 6 6 installation and user guide for the Intratone EEN REC2 V233 0011 AD receiver Sizes 180 66 143 46 110 116 33 I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Отзывы: